Effect of implant length variations on stress shielding in proximal humeral replacement after tumor excision under torsion: Finite element study

被引:0
|
作者
Pareatumbee, Pivatidevi [1 ]
Zainul-Abidin, Suraya [1 ,2 ,3 ]
Yew, Andy [1 ,3 ]
Chou, Siaw M. [4 ]
Sen Howe, Tet [1 ,2 ,3 ]
Koh, Joyce S. B. [1 ,2 ,3 ]
Tan, Mann Hong [1 ,2 ,3 ]
机构
[1] Singapore Gen Hosp, Singhlth Duke NUS Musculoskeletal Sci Acad Clin P, Singapore, Singapore
[2] Singapore Gen Hosp, Dept Orthoped Surg, Singapore, Singapore
[3] Singapore Gen Hosp, Div Musculoskeletal Sci, Singapore, Singapore
[4] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Singapore, Singapore
关键词
endoprosthetic reconstruction; finite element analysis; humeral tumors; implant lengths; stress shielding; ENDOPROSTHETIC RECONSTRUCTION; BONE;
D O I
10.1002/jor.25456
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The proximal humerus is the most common site of occurrence of primary bone tumors in the upper limb. Endoprosthetic replacement is deemed as the preferred reconstructive option following primary resection of bone tumors. However, it has been also associated with complications such as stress shielding and aseptic loosening compromising prosthetic survival. Our objective was to conduct a finite element (FE) study to investigate the effect of varying endoprosthesis length on bone stresses as well as to quantify the extent of stress shielding across the bone length (BL) in a humerus-prosthesis assembly for proximal humeral replacement after tumor excision thereby allowing us to identify the optimal implant length with best biomechanical performance. FE models of the intact humerus and humerus-prosthesis assemblies were established where they were loaded at the elbow joint under torsion with the glenohumeral joint fixed to represent twisting. After dividing the bone into individual slices consisting of 5% BL, the maximum cortical and cancellous principal, von Mises and shear bone stresses were calculated. To measure the level of stress shielding, the percentage stress change from the intact state was evaluated across each slice. Similar stress patterns were observed between the intact state and shorter endoprosthesis compared to the longer endoprostheses. Our findings illustrated the possibility of stress shielding occurring under torsional forces with its effect increasing with implant lengthening. To conclude, we believe that using a shorter prosthesis may substantially diminish the risk of potential implant failure due to stress shielding.
引用
收藏
页码:1139 / 1147
页数:9
相关论文
共 22 条
  • [1] Effect of Implant Design on Stress Distribution: A Finite Element Study
    Houshmand B.
    Ardakani M.T.
    Moscowchi A.
    Oskoui I.Z.
    Journal of Long-Term Effects of Medical Implants, 2022, 32 (04) : 39 - 45
  • [2] Finite Element Analysis of Bone Stress for Miniscrew Implant Proximal to Root Under Occlusal Force and Implant Loading
    Shan, Li-Hua
    Guo, Na
    Zhou, Guan-jun
    Qie, Hui
    Li, Chen-Xi
    Lu, Lin
    JOURNAL OF CRANIOFACIAL SURGERY, 2015, 26 (07) : 2072 - 2076
  • [3] The Effect of Implant Length and Diameter on Stress Distribution of Tooth-Implant and Implant Supported Fixed Prostheses: An In Vitro Finite Element Analysis Study
    Naguib, Ghada H.
    Hashem, Abou Bakr H.
    Natto, Zuhair S.
    Abougazia, Ahmed O.
    Mously, Hisham A.
    Hamed, Mohamed T.
    JOURNAL OF ORAL IMPLANTOLOGY, 2023, 49 (01) : 46 - 54
  • [4] Creation and finite-element analysis of multi-lattice structure design in hip stem implant to reduce the stress-shielding effect
    Gok, Mustafa Guven
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART L-JOURNAL OF MATERIALS-DESIGN AND APPLICATIONS, 2022, 236 (02) : 429 - 439
  • [5] Single implant retained overdentures: Evaluation of effect of implant length and diameter on stress distribution by finite element analysis
    Eraslan, Ravza
    Yagci, Filiz
    Esim, Emir
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (04): : 348 - 357
  • [6] Effect of screw thread length on stiffness of proximal humerus locking plate constructs: A finite element study
    Le, Louise
    Jabran, Ali
    Peach, Chris
    Ren, Lei
    MEDICAL ENGINEERING & PHYSICS, 2019, 63 : 79 - 87
  • [7] Finite element study on the effect of abutment length and material on implant bone interface against dynamic loading
    Mishra, Manish
    Ozawa, Shogo
    Masuda, Tatsuhiko
    Yoshioka, Fumi
    Tanaka, Yoshinobu
    JOURNAL OF ADVANCED PROSTHODONTICS, 2011, 3 (03) : 140 - 144
  • [8] A finite element study on stress distribution of two different attachment designs under implant supported overdenture
    El-Anwar, Mohamed I.
    Yousief, Salah A.
    Soliman, Tarek A.
    Saleh, Mahmoud M.
    Omar, Wael S.
    SAUDI DENTAL JOURNAL, 2015, 27 (04) : 201 - 207
  • [9] Stress Evaluation of Implant-Abutment Connections Under Different Loading Conditions: A 3D Finite Element Study
    Ferreira Koyama Takahashi, Jessica Mie
    Dayrell, Andreza Costa
    Xediek Consani, Rafael Leonardo
    de Arruda Nobilo, Mauro Antonio
    Pessanha Henriques, Guilherme Elias
    Mesquita, Marcelo Ferraz
    Journal of Oral Implantology, 2015, 41 (02) : 133 - 137
  • [10] Effect of implant- and occlusal load location on stress distribution in Locator attachments of mandibular overdenture. A finite element study
    Alvarez-Arenal, Angel
    Gonzalez-Gonzalez, Ignacio
    deLlanos-Lanchares, Hector
    Martin-Fernandez, Elena
    Brizuela-Velasco, Aritza
    Ellacuria-Echebarria, Joseba
    JOURNAL OF ADVANCED PROSTHODONTICS, 2017, 9 (05) : 371 - 380