Determination of restricted dyes in textile raw material solid wastes by ultra-high performance liquid chromatography-tandem mass spectrometry

被引:2
|
作者
Sun, Qianran [1 ]
Li, Yongli [1 ]
Su, Youzhi [2 ]
Wei, Mengyuan [3 ]
Li, Haitao [4 ]
Liu, Jun [1 ,5 ,6 ]
机构
[1] Chengdu Customs Dist, Technol Ctr, Chengdu 610000, Peoples R China
[2] Yining Customs Dist, Technol Ctr, Yining 835000, Peoples R China
[3] Shanghai Customs Dist, Shanghai 200135, Peoples R China
[4] Tianjin Phys & Chem Anal Ctr Co LTD, Tianjin 300051, Peoples R China
[5] Urumqi Customs Dist, Urumqi 830000, Peoples R China
[6] Chengdu Customs, Technol Ctr, 28, Yihuan Rd, Chengdu 611430, Peoples R China
关键词
Restricted dyes; UHPLC-MS/MS; Textile raw material solids waste; Ultrasonic extraction; DISPERSE DYES; ION SUPPRESSION; WATER; ELECTROSPRAY; EXTRACTION; THROUGHPUT; PRODUCTS; AZO;
D O I
10.1016/j.chroma.2023.464447
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid and highly sensitive method for the quantification of 34 restricted dyes (including acid, basic, disperse, direct, and azo dyes) in solid textile raw material wastes was developed by employing ultrasonic extraction coupled with ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS). More specifically, the proposed method employed methanol as the extraction solvent, while the mobile phases consisted of acetonitrile and 10 mmol/L ammonium acetate + 0.05% ammonia. A good linearity was achieved over the concentration range of 0.01-200 ng/mL with correlation coefficients (R) between 0.991-0.999, limits of detection (LODs) of 0.25-40.0 mu g/kg (S/N = 3) and limits of quantification (LOQs) of 0.84-133.4 mu g/kg (S/N = 10). 34 dyes were recovered at three levels ranging from 84.5 to 106.9% with relative standard deviation (RSDs) ranging from 0.59% to 10.61%. Further, the method was applied for the accurate analysis of 32 counts of cotton yarn, waste cotton, and printed fabrics within 15 min. The dyestuffs accurately quantified by this rapid chromatographic procedure covered a wide range of carcinogenic and allergenic dyestuffs listed in the Oeko-Tex Standard 100 (version 02.2023) colourants. The ultrasound technique combined with the ultra-high performance liquid chromatography-tandem mass spectrometry method proposed in this work is thus suitable for the rapid screening, confirmation, and quantitative detection of industrial synthetic dyes within solid waste originating from textile raw materials.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Simultaneous determination of 17 disperse dyes in textile by ultra-high performance supercritical fluid chromatography combined with tandem mass spectrometry
    Zhou, Ying
    Du, Zhenxia
    Zhang, Yun
    TALANTA, 2014, 127 : 108 - 115
  • [2] Simultaneous determination of 20 disperse dyes in foodstuffs by ultra high performance liquid chromatography-tandem mass spectrometry
    Liu, Weiguo
    Liu, Jun
    Zhang, Yu
    Chen, Yinguang
    Yang, Xiaodong
    Duan, Luchun
    Dharmarajan, Rajarathnam
    Wang, Xiyuan
    Li, Lan
    FOOD CHEMISTRY, 2019, 300
  • [3] Determination of mitomycin C in rabbit plasma by ultra-high performance liquid chromatography-tandem mass spectrometry
    Tang Yao
    Zhang Shuangqing
    Li Xiang
    Sun Xu
    Wen Nie
    Yu Min
    Peng Lili
    Li Jinrang
    Li Zuogang
    Li Bo
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2012, 30 (02) : 154 - 159
  • [4] Simultaneous determination of parabens, bisphenols and alkylphenols in human placenta by ultra-high performance liquid chromatography-tandem mass spectrometry
    Van Overmeire, Ilse
    Vrijens, Karen
    Nawrot, Tim
    Van Nieuwenhuyse, An
    Van Loco, Joris
    Reyns, Tim
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1121 : 96 - 102
  • [5] Determination of Mycotoxins in Cereal-Based Porridge Destined for Infant Consumption by Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry
    Sartori, Andre Victor
    Paulino de Moraes, Maria Heloisa
    dos Santos, Rosana Pereira
    Souza, Yuri Pereira
    da Nobrega, Armi Wanderley
    FOOD ANALYTICAL METHODS, 2017, 10 (12) : 4049 - 4061
  • [6] Determination of Key Compositions of Biogenic Hydrolysate Materials by Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry
    Tian, Meng-Yuan
    Zhang, Jin
    Guo, Guo
    Li, Bo-Yan
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2023, 51 (09) : 1494 - 1505
  • [7] Determination of naphthalene-derived compounds in apples by ultra-high performance liquid chromatography-tandem mass spectrometry
    Esparza, X.
    Moyano, E.
    Cosialls, J. R.
    Galceran, M. T.
    ANALYTICA CHIMICA ACTA, 2013, 782 : 28 - 36
  • [8] Rapid Determination of Five Alternaria Mycotoxins in Citrus by Ultra-high Performance Liquid Chromatography-Tandem Mass Spectrometry
    Jiang Li-Yan
    Zhao Qi-Yang
    Gong Lei
    Liu Yan-Yu
    Zhang Yao-Hai
    Ma Liang
    Jiao Bi-Ning
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (12) : 1851 - 1858
  • [9] Determination of Chlorpyrifos and Its Main Metabolite in Tea by Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry
    Yin Peng
    Guo Gui-Yi
    Dai Jin-Xia
    Zhu Li
    Gao Guan-Wei
    Chen Hong-Ping
    Liu Xin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 47 (02) : 306 - 314
  • [10] Determination of 82 veterinary drugs in swine waste lagoon sludge by ultra-high performance liquid chromatography-tandem mass spectrometry
    Li, Xiaowei
    Guo, Ping
    Shan, Yawen
    Ke, Yuebin
    Li, Hui
    Fu, Qin
    Wang, Yingyu
    Liu, Tianhe
    Xia, Xi
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1499 : 57 - 64