Experimental study on the performance of shear connections between local UHPC slabs and GFRP girders

被引:3
|
作者
Liu, Renlong [1 ]
Cheng, Zhanqi [1 ,2 ]
Yang, Sen [1 ]
Zhang, Pu [1 ]
Hu, Yi [3 ]
Ye, Ning [4 ]
机构
[1] Zhengzhou Univ, Sch Hydraul & Civil Engn, Zhengzhou 450001, Peoples R China
[2] Zhengzhou Univ, Yellow River Lab, Zhengzhou 450001, Peoples R China
[3] China Informat Technol Designing & Consulting Inst, Beijing 100048, Peoples R China
[4] City Construction Dev Ctr Henan Prov, Zhengzhou 450001, Peoples R China
基金
中国国家自然科学基金;
关键词
FRP-concrete hybrid beams; Local UHPC; Hybrid interface; Push-out test; Bolted shear connection; BEHAVIOR; STRENGTH; TESTS; BEAMS;
D O I
10.1016/j.istruc.2023.05.090
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper proposes a novel fiber-reinforced polymer (FRP)-concrete hybrid system with local ultrahighperformance concrete (UHPC) in key parts to accelerate construction and reduce the cost of UHPC. Fifteen push-out specimens were tested to investigate the shear behavior of the UHPC-FRP hybrid interface embedded with bolts in a local UHPC slab. The parameters varied were the local UHPC width, types of concrete slabs, bolt diameter, bolt number and bolt embedding length in concrete. Push-out test results showed that (1) the increase in bolt embedding length substantially reduced the bearing capacity, with a maximum reduction of 25.8%; (2) the interfacial bearing capacity and rigidity increased significantly with increasing bolt diameter, while the excessive diameter may cause the failure of GFRP flange shear-out; (3) the increase of the number of bolts improved the interface performance, but decreased the efficiency of a single bolt utilization; (4) the employment of local UHPC increased the slip stiffness by 16.9%, which had similar shear performance to that of the whole UHPC slab; (5) further changing the local UHPC width had little effect on the shear performance of the push-out specimens. Finally, the calculation method of the bolt shear bearing capacity considering the influence of the embedded length was proposed by modifying the existing formula.
引用
收藏
页码:1966 / 1979
页数:14
相关论文
共 50 条
  • [41] Experimental study on demountable shear connectors in composite slabs with profiled decking
    Rehman, N.
    Lam, D.
    Dai, X.
    Ashour, A. F.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 122 : 178 - 189
  • [42] Experimental Study of UHPC-RC Composite Pile Connected by Shear Keys
    Zhang, Yongtao
    Zheng, Hehui
    Li, Gang
    STRUCTURAL ENGINEERING INTERNATIONAL, 2022, 32 (02) : 189 - 202
  • [43] Experimental and analytical performance of replaceable shear fuse connections for heavy beams
    Richards, Paul W.
    Lee, Hooseok
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2023, 208
  • [44] Experimental investigation of the influence of fibre content on the flexural performance of simply supported and continuous steel/UHPC composite slabs
    Chen, Sirui
    Visintin, Phillip
    Oehlers, Deric J.
    STEEL AND COMPOSITE STRUCTURES, 2023, 49 (05) : 571 - 585
  • [45] Experimental and numerical investigation on mechanical performance of continuous steel-UHPC composite slabs
    Xiao, Jing-Lin
    Yang, Teng-Yu
    Nie, Xin
    Li, Bai-Yun
    Fan, Jian-Sheng
    Shu, Ben -An
    ENGINEERING STRUCTURES, 2022, 270
  • [46] Research on the bond performance between glass fiber reinforced polymer (GFRP) bars and Ultra-high performance concrete(UHPC)
    Xiao, Jie
    Liu, Lingfei
    Zeng, Hehui
    Zhai, Keyi
    Fu, Jundong
    Jiang, Haibo
    Pang, Lei
    JOURNAL OF BUILDING ENGINEERING, 2024, 98
  • [47] An Experimental Study on Punching Shear Behavior of Concrete Slabs
    Alam, A. K. M. Jahangir
    Amanat, Khan Mahmud
    Seraj, Salek M.
    ADVANCES IN STRUCTURAL ENGINEERING, 2009, 12 (02) : 257 - 265
  • [48] Experimental and Theoretical Investigation of the Punching Shear Strength of GFRP-Reinforced Two-Way Slabs
    Kurtoglu, Ahmet Emin
    Bilgehan, Mahmut
    Gulsan, Mehmet Eren
    Cevik, Abdulkadir
    STRUCTURAL ENGINEERING INTERNATIONAL, 2023, 33 (03) : 379 - 388
  • [49] Experimental and analytical punching shear behavior of reinforced concrete flat slabs having internal GFRP gratings
    Mostafa, Haitham M. F.
    Mahmoud, Ahmed A.
    Mostafa, Tarek S.
    Khater, Ahmed N. M.
    STRUCTURES, 2024, 60
  • [50] Experimental and numerical study on the shear performance of stainless steel-GFRP connectors for use in precast concrete sandwich panels
    Zhao, Boyi
    Du, Lingfeng
    Chen, Guixiang
    Yue, Longfei
    Cui, Chenxing
    Ge, Mengmeng
    SCIENTIFIC REPORTS, 2024, 14 (01):