Study of combined heat and power plant integration with thermal energy storage for operational flexibility

被引:38
|
作者
Chen, Chengxu [1 ]
Ge, Zhihua [1 ]
Zhang, Youjun [1 ]
机构
[1] North China Elect Power Univ, Key Lab Power Stn Energy Transfer Convers & Syst, Minist Educ, Beijing 102206, Peoples R China
关键词
Combined heat and power; Thermal energy storage; Power plant flexibility; Thermodynamic analysis; Peak shaving capacity; COMPREHENSIVE ANALYSIS; GENERATION SYSTEM; EXERGY ANALYSIS; ELECTRIC-POWER; FEEDWATER; SOLAR; OPTIMIZATION; PERFORMANCE; COGENERATION; TECHNOLOGIES;
D O I
10.1016/j.applthermaleng.2022.119537
中图分类号
O414.1 [热力学];
学科分类号
摘要
Increasing the share of renewable energy in the future electricity market requires measures to maintain the stability of the grid, owing to the volatility and intermittency of renewable energy. For a combined heat and power (CHP) plant, molten salt thermal energy storage (TES) can be added to improve the flexibility to meet the needs of peak shaving. This paper proposed a novel cascade reheat steam extraction system to adjust the elec-trical load by using EBSILON software applied to thermal simulation and thermal analysis. A 350 MW super-critical CHP plant was used as an example to analyze the thermal and peak shaving performance under variable operating conditions. Meanwhile, through the static simulation, the change in the load and the efficiency of TES can be calculated during the charging and discharging cycle. The results show that the efficiency of TES is 40-51 %. With an increase in the load, the efficiency of TES is reduced, and the exergy loss range is from 4 MW to 12.4 MW mainly due to the throttling process and the molten salt heat transfer process. Moreover, the thermal ef-ficiency and exergy efficiency of the novel system are higher than those of the traditional CHP plant below 60 % turbine heat acceptance, so it is relatively economical to run for peak shaving under low loads. Finally, depending on the corresponding operating strategy, a reduction of the minimum load by up to 1 % of the rated output electrical load during charging and an increase of the maximum load by up to 2 % of the rated output electrical load during discharging are possible. Overall, the proposed system provides a feasible method for the flexibilization of CHP plants alongside new renewable systems.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Comparative study on flexibility enhancement of combined heat and power for wind power accommodation
    Chen, Chengxu
    Zhang, Yichen
    Ge, Zhihua
    Du, Xiaoze
    ELsihy, ELSaeed Saad
    APPLIED THERMAL ENGINEERING, 2023, 235
  • [22] Heat-power peak shaving and wind power accommodation of combined heat and power plant with thermal energy storage and electric heat pump
    Wang, Haichao
    Han, Jianbo
    Zhang, Ruoyu
    Sun, Mingyi
    Sun, Zongyu
    Hua, Pengmin
    Xie, Zichan
    Wang, Hai
    Abdollahi, Elnaz
    Lahdelma, Risto
    Granlund, Katja
    Teppo, Esa
    ENERGY CONVERSION AND MANAGEMENT, 2023, 297
  • [23] Energy Storage Improves Power Plant Flexibility and Economic Performance
    Sarunac, Nenad
    Khalesi, Javad
    Khuda, Mahfuja A.
    Mancini, Rick
    Kulkarni, Pramod
    Berger, Joel
    ENERGIES, 2024, 17 (11)
  • [24] Comprehensive analysis of a novel integration of a biomass-driven combined heat and power plant with a compressed air energy storage (CAES)
    Lashgari, Fatemeh
    Arabkoohsar, Ahmad
    Babaei, Seyed Mostafa
    Pedram, Mona Zamani
    ENERGY CONVERSION AND MANAGEMENT, 2022, 255
  • [25] Integration of Thermal Energy Storage Systems and Thermodynamic Analysis of Solar Combined Power Plants
    Al-Doori, Ghaith Thaaer Fadhil
    Abed, Falah Mohammed
    Faisal, Hayder Subhi
    INTERNATIONAL JOURNAL OF MULTIPHYSICS, 2024, 18 (03) : 1494 - 1512
  • [26] Flexibility and efficiency co-enhancement of thermal power plant by control strategy improvement considering time varying and detailed boiler heat storage characteristics
    Wang, Zhu
    Liu, Ming
    Yan, Junjie
    ENERGY, 2021, 232 (232)
  • [27] Study of supercritical power plant integration with high temperature thermal energy storage for flexible operation
    Li, Decai
    Wang, Jihong
    JOURNAL OF ENERGY STORAGE, 2018, 20 : 140 - 152
  • [28] Phase-change heat storage installation in combined heat and power plants for integration of renewable energy sources into power system
    Hu, Kang
    Chen, Lei
    Chen, Qun
    Wang, Xiao-Hai
    Qi, Jun
    Xu, Fei
    Min, Yong
    ENERGY, 2017, 124 : 640 - 651
  • [29] Sizing and optimizing the operation of thermal energy storage units in combined heat and power plants: An integrated modeling approach
    Benalcazar, Pablo
    ENERGY CONVERSION AND MANAGEMENT, 2021, 242
  • [30] Modeling of a thermal energy storage system coupled with combined heat and power generation for the heating requirements of a University Campus
    Pagliarini, Giorgio
    Rainieri, Sara
    APPLIED THERMAL ENGINEERING, 2010, 30 (10) : 1255 - 1261