Cardiac Output and Stroke Volume Assessments by Transthoracic Echocardiography and Pulse index Continuous Cardiac Output Monitor in Critically ill Adult Patients: A Comparative Study

被引:0
|
作者
Gomes, Flavia K. A. [1 ,2 ,3 ]
Fagundes Jr, Antonio A. de P. [2 ]
Amorim, Fabio F. [1 ,4 ,5 ]
机构
[1] Higher Educ Sch Hlth Sci ESCS, Grad Program Hlth Sci, Brasilia, DF, Brazil
[2] Hosp DF Star, Adult Intens Care Unit, Brasilia, DF, Brazil
[3] Hosp Home, Adult Intens Care Unit, Brasilia, DF, Brazil
[4] Univ Brasilia UnB, Grad Program Hlth Sci, Brasilia, DF, Brazil
[5] Escola Super Ciencias Saude ESCS, Lab Saude Baseada Evidencias, SMHN Conjunto A Bloco 01 Edificio Fepecs Asa Norte, Brasilia, DF, Brazil
关键词
cardiac output; stroke volume; echocardiography; ultrasound; PiCCO; PULMONARY-ARTERY CATHETER; DOPPLER-ECHOCARDIOGRAPHY; EUROPEAN ASSOCIATION; ULTRASOUND; PRESSURE; THERMODILUTION; SHOCK;
D O I
10.1177/08850666231204787
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: Bedside transthoracic echocardiography (TTEcho) is a noninvasive cardiac output (CO) monitoring method that has grown recently. However, there are questions regarding its accuracy compared to invasive methods. We aimed to evaluate the agreement and correlation of TTEcho and pulse index continuous CO (PiCCO) monitor measurements for CO and systolic volume (SV) in critically ill patients. Methods: This prospective experimental study included consecutive adult patients who required invasive hemodynamic monitoring admitted at an intensive care unit in the Federal District, Brazil, from January/2019 to January/2021. Correlation and agreement between SV and CO measurements by PiCCO and TTEcho were performed using the Spearman correlation and the Bland-Altman analysis. Results: The study enrolled 29 patients, with adequate TTEcho evaluations in all patients. There were very strong correlations between CO-TTEcho and CO-PiCCO (r = 0.845, P < .001) and SV-TTEcho and SV-PiCCO (r = 0.800, P < .001). TTEcho estimations for CO and SV were feasible within the limits of agreement in 96.6% (28/29) compared to PiCCO. The mean difference between CO-PiCCO and CO-TTEcho was 0.250 L/min (limits of agreement: -1.083 to 1.583 L/min, percentage error: 21.0%), and between SV-PiCCO and SV-TTEcho was 2.000 mL (limits of agreement: -16.960 to 20.960, percentage error: 24.3%). The reduced cardiac index (CI) measurements by TTEcho showed an accuracy of 89.7% (95% IC: 72.6%-97.8%) and an F1 score of 92.7% (95% IC: 75.0%-98.0%), considering the CI-PiCCO as the gold standard. Conclusion: Echocardiographic measurements of CO and SV are comparable to measurements by PiCCO. These results reinforce echocardiography as a reliable tool to evaluate hemodynamics in critically ill patients.
引用
收藏
页码:341 / 348
页数:8
相关论文
共 50 条
  • [31] Comparison of cardiac output and cardiac index values measured by critical care echocardiography with the values measured by pulse index continuous cardiac output (PiCCO) in the pediatric intensive care unit:a preliminary study
    Aslan, Nagehan
    Yildizdas, Dincer
    Horoz, Ozden Ozgur
    Coban, Yasemin
    Demir, Fadli
    Erdem, Sevcan
    Sertdemir, Yasar
    ITALIAN JOURNAL OF PEDIATRICS, 2020, 46 (01)
  • [32] Comparison of cardiac output and cardiac index values measured by critical care echocardiography with the values measured by pulse index continuous cardiac output (PiCCO) in the pediatric intensive care unit:a preliminary study
    Nagehan Aslan
    Dincer Yildizdas
    Ozden Ozgur Horoz
    Yasemin Coban
    Fadli Demir
    Sevcan Erdem
    Yasar Sertdemir
    Italian Journal of Pediatrics, 46
  • [33] Is continuous cardiac output measurement as accurate as intermittent bolus thermodilution cardiac output measurement in critically ill low ejection fraction patients?
    Gawlinski, A
    Attin, M
    CIRCULATION, 1998, 98 (17) : 693 - 693
  • [34] THE INITIAL DISTRIBUTION VOLUME OF GLUCOSE AND CARDIAC-OUTPUT IN THE CRITICALLY ILL
    ISHIHARA, H
    SHIMODATE, Y
    KOH, H
    ISOZAKI, KI
    TSUBO, T
    MATSUKI, A
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1993, 40 (01): : 28 - 31
  • [35] Comparison of a noninvasive cardiac output monitor (NICOM) with simultaneous transthoracic echocardiography in pregnant women
    Florio, Karen
    Williams, Emily
    White, Darcy
    Daming, Tara Banaszek
    Hostetter, Sarah
    Schrufer-Poland, Tabitha L.
    Gray, Rebecca
    Schmidt, Laura
    Grodzinsky, Anna
    Lee, John
    Rader, Valerie
    Swearingen, Kathleen
    Nelson, Lynne
    Magalaski, Anthony
    Spertus, John
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2023, 228 (01) : S338 - S338
  • [36] Validation of continuous thermodilution cardiac output in critically ill patients with analysis of systematic errors
    Medin, DL
    Brown, DT
    Wesley, R
    Cunnion, RE
    Ognibene, FP
    JOURNAL OF CRITICAL CARE, 1998, 13 (04) : 184 - 189
  • [37] A Perspective on Non-invasive Continuous Cardiac Output in the Critically Ill
    Kim, Y. S.
    Immink, R. V.
    Jellema, W. T.
    van Lieshout, J. J.
    NETHERLANDS JOURNAL OF CRITICAL CARE, 2007, 11 (04): : 185 - 191
  • [38] Noninvasive monitoring of cardiac output in critically ill patients: transesophageal Doppler vs transesophageal echocardiography
    H Quintard
    A Cariou
    K Jabbour
    S Lasocki
    P Montravers
    J Dhainaut
    J Desmonts
    Critical Care, 10 (Suppl 1):
  • [39] Spontaneous variability of cardiac output in ventilated critically ill patients
    Huang, CC
    Tsai, YH
    Chen, NH
    Lin, MC
    Tsao, TCY
    Lee, CH
    Hsu, KH
    CRITICAL CARE MEDICINE, 2000, 28 (04) : 941 - 946
  • [40] Backrest angle and cardiac output measurement in critically ill patients
    Giuliano, KK
    Scott, SS
    Brown, V
    Olson, M
    NURSING RESEARCH, 2003, 52 (04) : 242 - 248