Cardiac Output and Stroke Volume Assessments by Transthoracic Echocardiography and Pulse index Continuous Cardiac Output Monitor in Critically ill Adult Patients: A Comparative Study

被引:0
|
作者
Gomes, Flavia K. A. [1 ,2 ,3 ]
Fagundes Jr, Antonio A. de P. [2 ]
Amorim, Fabio F. [1 ,4 ,5 ]
机构
[1] Higher Educ Sch Hlth Sci ESCS, Grad Program Hlth Sci, Brasilia, DF, Brazil
[2] Hosp DF Star, Adult Intens Care Unit, Brasilia, DF, Brazil
[3] Hosp Home, Adult Intens Care Unit, Brasilia, DF, Brazil
[4] Univ Brasilia UnB, Grad Program Hlth Sci, Brasilia, DF, Brazil
[5] Escola Super Ciencias Saude ESCS, Lab Saude Baseada Evidencias, SMHN Conjunto A Bloco 01 Edificio Fepecs Asa Norte, Brasilia, DF, Brazil
关键词
cardiac output; stroke volume; echocardiography; ultrasound; PiCCO; PULMONARY-ARTERY CATHETER; DOPPLER-ECHOCARDIOGRAPHY; EUROPEAN ASSOCIATION; ULTRASOUND; PRESSURE; THERMODILUTION; SHOCK;
D O I
10.1177/08850666231204787
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: Bedside transthoracic echocardiography (TTEcho) is a noninvasive cardiac output (CO) monitoring method that has grown recently. However, there are questions regarding its accuracy compared to invasive methods. We aimed to evaluate the agreement and correlation of TTEcho and pulse index continuous CO (PiCCO) monitor measurements for CO and systolic volume (SV) in critically ill patients. Methods: This prospective experimental study included consecutive adult patients who required invasive hemodynamic monitoring admitted at an intensive care unit in the Federal District, Brazil, from January/2019 to January/2021. Correlation and agreement between SV and CO measurements by PiCCO and TTEcho were performed using the Spearman correlation and the Bland-Altman analysis. Results: The study enrolled 29 patients, with adequate TTEcho evaluations in all patients. There were very strong correlations between CO-TTEcho and CO-PiCCO (r = 0.845, P < .001) and SV-TTEcho and SV-PiCCO (r = 0.800, P < .001). TTEcho estimations for CO and SV were feasible within the limits of agreement in 96.6% (28/29) compared to PiCCO. The mean difference between CO-PiCCO and CO-TTEcho was 0.250 L/min (limits of agreement: -1.083 to 1.583 L/min, percentage error: 21.0%), and between SV-PiCCO and SV-TTEcho was 2.000 mL (limits of agreement: -16.960 to 20.960, percentage error: 24.3%). The reduced cardiac index (CI) measurements by TTEcho showed an accuracy of 89.7% (95% IC: 72.6%-97.8%) and an F1 score of 92.7% (95% IC: 75.0%-98.0%), considering the CI-PiCCO as the gold standard. Conclusion: Echocardiographic measurements of CO and SV are comparable to measurements by PiCCO. These results reinforce echocardiography as a reliable tool to evaluate hemodynamics in critically ill patients.
引用
收藏
页码:341 / 348
页数:8
相关论文
共 50 条
  • [1] Transthoracic echocardiography: an accurate and precise method for estimating cardiac output in the critically ill
    Mercado, Pablo
    Maizel, Julien
    Beyls, Christophe
    Titeca-Beauport, Dimitri
    Joris, Magalie
    Kontar, Loay
    Riviere, Antoine
    Bonef, Olivier
    Soupison, Thierry
    Tribouilloy, Christophe
    de Cagny, Bertrand
    Slama, Michel
    CRITICAL CARE, 2017, 21
  • [2] COMPARISON OF CARDIAC OUTPUT MEASUREMENTS BETWEEN TRANSTHORACIC ECHOCARDIOGRAPHY AND THERMODILUTION METHOD IN CRITICALLY ILL PATIENTS
    Gomes, Flavia
    Arruda, Mariana
    Fagundes, Antonio, Jr.
    Amorim, Fabio Ferreira
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 1491 - 1491
  • [3] STROKE VOLUME AND CARDIAC OUTPUT BY ECHOCARDIOGRAPHY
    KINGSLEY, B
    JOURNAL OF THE AUDIO ENGINEERING SOCIETY, 1970, 18 (06): : 692 - &
  • [4] CARDIAC POWER OUTPUT IN CRITICALLY ILL SURGICAL PATIENTS: A SIMULTANEOUS PULMONARY ARTERY CATHETERIZATION AND TRANSTHORACIC ECHOCARDIOGRAPHY STUDY
    Mehmood, Muddassir
    Tchorz, Kathryn
    Markert, Ronald
    Chandra, Mukul
    McCarthy, Mary
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1126 - E1126
  • [5] EVALUATION OF A NEW CONTINUOUS THERMODILUTION CARDIAC-OUTPUT MONITOR IN CRITICALLY ILL PATIENTS
    HALLER, M
    ZOLLNER, C
    BRIEGEL, J
    POLASEK, J
    FORST, H
    ANESTHESIOLOGY, 1994, 81 (3A) : A514 - A514
  • [6] A prospective study to evaluate the accuracy of pulse power analysis to monitor cardiac output in critically ill patients
    Cecconi M.
    Fawcett J.
    Grounds R.M.
    Rhodes A.
    BMC Anesthesiology, 8 (1)
  • [7] Transthoracic echocardiography: an accurate and precise method for estimating cardiac output in the critically ill patient
    Pablo Mercado
    Julien Maizel
    Christophe Beyls
    Dimitri Titeca-Beauport
    Magalie Joris
    Loay Kontar
    Antoine Riviere
    Olivier Bonef
    Thierry Soupison
    Christophe Tribouilloy
    Bertrand de Cagny
    Michel Slama
    Critical Care, 21
  • [8] Stroke Volume Measurements by Echocardiography and Ultrasonic Cardiac Output Monitor in Children
    Fremuth, Jiri
    Huml, Michal
    Pomahacova, Tereza
    Kobr, Jiri
    Kormunda, Stanislav
    Sykora, Josef
    PEDIATRIC EMERGENCY CARE, 2023, 39 (09) : 680 - 684
  • [9] Comparison of cardiac output measurements in critically ill patients: Flotrac/Vigileo vs transthoracic Doppler echocardiography
    McLean, A. S.
    Huang, S. J.
    Kot, M.
    Rajamani, A.
    Hoyling, L.
    ANAESTHESIA AND INTENSIVE CARE, 2011, 39 (04) : 590 - 598
  • [10] Echocardiography for cardiac output assessment in critically ill patientsY
    Lips, M.
    Krupicka, J.
    Korinek, J.
    Kunstyr, J.
    ANESTEZIOLOGIE A INTENZIVNI MEDICINA, 2015, 26 (04): : 228 - 232