Cardiac Output and Stroke Volume Assessments by Transthoracic Echocardiography and Pulse index Continuous Cardiac Output Monitor in Critically ill Adult Patients: A Comparative Study

被引:0
|
作者
Gomes, Flavia K. A. [1 ,2 ,3 ]
Fagundes Jr, Antonio A. de P. [2 ]
Amorim, Fabio F. [1 ,4 ,5 ]
机构
[1] Higher Educ Sch Hlth Sci ESCS, Grad Program Hlth Sci, Brasilia, DF, Brazil
[2] Hosp DF Star, Adult Intens Care Unit, Brasilia, DF, Brazil
[3] Hosp Home, Adult Intens Care Unit, Brasilia, DF, Brazil
[4] Univ Brasilia UnB, Grad Program Hlth Sci, Brasilia, DF, Brazil
[5] Escola Super Ciencias Saude ESCS, Lab Saude Baseada Evidencias, SMHN Conjunto A Bloco 01 Edificio Fepecs Asa Norte, Brasilia, DF, Brazil
关键词
cardiac output; stroke volume; echocardiography; ultrasound; PiCCO; PULMONARY-ARTERY CATHETER; DOPPLER-ECHOCARDIOGRAPHY; EUROPEAN ASSOCIATION; ULTRASOUND; PRESSURE; THERMODILUTION; SHOCK;
D O I
10.1177/08850666231204787
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: Bedside transthoracic echocardiography (TTEcho) is a noninvasive cardiac output (CO) monitoring method that has grown recently. However, there are questions regarding its accuracy compared to invasive methods. We aimed to evaluate the agreement and correlation of TTEcho and pulse index continuous CO (PiCCO) monitor measurements for CO and systolic volume (SV) in critically ill patients. Methods: This prospective experimental study included consecutive adult patients who required invasive hemodynamic monitoring admitted at an intensive care unit in the Federal District, Brazil, from January/2019 to January/2021. Correlation and agreement between SV and CO measurements by PiCCO and TTEcho were performed using the Spearman correlation and the Bland-Altman analysis. Results: The study enrolled 29 patients, with adequate TTEcho evaluations in all patients. There were very strong correlations between CO-TTEcho and CO-PiCCO (r = 0.845, P < .001) and SV-TTEcho and SV-PiCCO (r = 0.800, P < .001). TTEcho estimations for CO and SV were feasible within the limits of agreement in 96.6% (28/29) compared to PiCCO. The mean difference between CO-PiCCO and CO-TTEcho was 0.250 L/min (limits of agreement: -1.083 to 1.583 L/min, percentage error: 21.0%), and between SV-PiCCO and SV-TTEcho was 2.000 mL (limits of agreement: -16.960 to 20.960, percentage error: 24.3%). The reduced cardiac index (CI) measurements by TTEcho showed an accuracy of 89.7% (95% IC: 72.6%-97.8%) and an F1 score of 92.7% (95% IC: 75.0%-98.0%), considering the CI-PiCCO as the gold standard. Conclusion: Echocardiographic measurements of CO and SV are comparable to measurements by PiCCO. These results reinforce echocardiography as a reliable tool to evaluate hemodynamics in critically ill patients.
引用
收藏
页码:341 / 348
页数:8
相关论文
共 50 条
  • [1] Transthoracic echocardiography: an accurate and precise method for estimating cardiac output in the critically ill
    Mercado, Pablo
    Maizel, Julien
    Beyls, Christophe
    Titeca-Beauport, Dimitri
    Joris, Magalie
    Kontar, Loay
    Riviere, Antoine
    Bonef, Olivier
    Soupison, Thierry
    Tribouilloy, Christophe
    de Cagny, Bertrand
    Slama, Michel
    CRITICAL CARE, 2017, 21
  • [2] Echocardiography for cardiac output assessment in critically ill patientsY
    Lips, M.
    Krupicka, J.
    Korinek, J.
    Kunstyr, J.
    ANESTEZIOLOGIE A INTENZIVNI MEDICINA, 2015, 26 (04): : 228 - 232
  • [3] A prospective study to evaluate the accuracy of pulse power analysis to monitor cardiac output in critically ill patients
    Cecconi M.
    Fawcett J.
    Grounds R.M.
    Rhodes A.
    BMC Anesthesiology, 8 (1)
  • [4] Stroke Volume Measurements by Echocardiography and Ultrasonic Cardiac Output Monitor in Children
    Fremuth, Jiri
    Huml, Michal
    Pomahacova, Tereza
    Kobr, Jiri
    Kormunda, Stanislav
    Sykora, Josef
    PEDIATRIC EMERGENCY CARE, 2023, 39 (09) : 680 - 684
  • [5] Comparison of cardiac output measurements in critically ill patients: Flotrac/Vigileo vs transthoracic Doppler echocardiography
    McLean, A. S.
    Huang, S. J.
    Kot, M.
    Rajamani, A.
    Hoyling, L.
    ANAESTHESIA AND INTENSIVE CARE, 2011, 39 (04) : 590 - 598
  • [6] Transthoracic echocardiographic assessment of cardiac output in mechanically ventilated critically ill patients by intensive care unit physicians
    Bergamaschi, Valentina
    Vignazia, Gian Luca
    Messina, Antonio
    Colombo, Davide
    Cammarota, Gianmaria
    Della Corte, Francesco
    Traversi, Egidio
    Navalesi, Paolo
    REVISTA BRASILEIRA DE ANESTESIOLOGIA, 2019, 69 (01): : 20 - 26
  • [7] Pulse Wave Transit Time Measurements of Cardiac Output in Septic Shock Patients: A Comparison of the Estimated Continuous Cardiac Output System with Transthoracic Echocardiography
    Feissel, Marc
    Aho, Ludwig Serge
    Georgiev, Stefan
    Tapponnier, Romain
    Badie, Julio
    Bruyere, Remi
    Quenot, Jean-Pierre
    PLOS ONE, 2015, 10 (06):
  • [8] Comparison of electrical velocimetry and transthoracic thermodilution technique for cardiac output assessment in critically ill patients
    Raue, Wieland
    Swierzy, Marc
    Koplin, Gerold
    Schwenk, Wolfgang
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2009, 26 (12) : 1067 - 1071
  • [9] Echo is a good, not perfect, measure of cardiac output in critically ill surgical patients
    Olivieri, Peter P.
    Patel, Rajan
    Kolb, Stephanie
    Fatima, Syeda
    Galvagno, Samuel M.
    Haase, Daniel J.
    Ramani, Gautam V.
    Ludmir, Jonathan
    Alkhatib, Hani
    Herr, Daniel
    Bruno, David A.
    Scalea, Thomas M.
    Murthi, Sarah B.
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2019, 87 (02) : 379 - 385
  • [10] Transthoracic echocardiography: an accurate and precise method for estimating cardiac output in the critically ill patient
    Pablo Mercado
    Julien Maizel
    Christophe Beyls
    Dimitri Titeca-Beauport
    Magalie Joris
    Loay Kontar
    Antoine Riviere
    Olivier Bonef
    Thierry Soupison
    Christophe Tribouilloy
    Bertrand de Cagny
    Michel Slama
    Critical Care, 21