Comparison of Carotid Blood Flow Measured by Ultrasound and Cardiac Output in Patients Undergoing Cardiac Surgery

被引:1
作者
Bu, Xin-yi [1 ]
Wang, Jian-kai [2 ]
Zhang, Yong [1 ]
Chen, Li-hai [1 ]
Liu, Jia-cong [1 ]
Zhao, Ya-mei [1 ]
Shi, Hong-wei [1 ]
Ge, Ya-li [1 ]
机构
[1] Nanjing Med Univ, Nanjing Hosp 1, Dept Anesthesiol, Nanjing 210029, Jiangsu, Peoples R China
[2] Nanjing Med Univ, Nanjing Hosp 1, Dept Cardiothorac & Vasc Surg, Nanjing 210029, Jiangsu, Peoples R China
关键词
carotid artery; cardiac output; cardiac surgery; carotid ul-trasound; transesophageal echocardiograph; OXYGEN-CONSUMPTION; DOPPLER; VOLUME;
D O I
10.1532/hsf.5465
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: In general, cerebral blood flow accounts for 10-15% of cardiac output (CO), of which about 75% is de-livered through the carotid arteries. Hence, if carotid blood flow (CBF) is constantly proportional to CO with high re-producibility and reliability, it would be of great value to measure CBF as an alternative to CO. The aim of this study was to investigate the direct correlation between CBF and CO. We hypothesized that measurement of CBF could be a good substitute for CO, even under more extreme hemo-dynamic conditions, for a wider range of critically ill pa-tients. Methods: Patients aged 65-80 years, undergoing elective cardiac surgery were included in this study. CBF in different cardiac cycles were measured by ultrasound: systolic carotid blood flow (SCF), diastolic carotid blood flow (DCF), and total (systolic and diastolic) carotid blood flow (TCF). CO simultaneously was measured by trans -esophageal echocardiography. Results: For all patients, the correlation coefficients between SCF and CO, TCF and CO were 0.45 and 0.30, respectively, which were statisti-cally significant, but not between DCF and CO. There was no significant correlation between either SCF, TCF or DCF and CO, when CO was <3.5 L/min. Conclusions: Systolic carotid blood flow may be used as a better index to replace CO. However, the method of direct measurement of CO is essential when the patient's heart function is poor.
引用
收藏
页码:E234 / E239
页数:6
相关论文
共 14 条
  • [1] Doppler Sonography evaluation of flow velocity and volume of the extracranial internal carotid and vertebral arteries in healthy adults
    Albayrak, Ramazan
    Degirmenci, Bumin
    Acar, Murat
    Haktanir, Alpay
    Colbay, Mehmet
    Yaman, Mehmet
    [J]. JOURNAL OF CLINICAL ULTRASOUND, 2007, 35 (01) : 27 - 33
  • [2] Comparison of cardiac output measured by carotid artery Doppler ultrasound and echocardiography in patients admitted to Golestan and Imam Khomeyni Hospitalsl in Ahvaz
    Fazelinejad, Zahra
    Hanafi, Mohammad Ghasem
    Amiripebdani, Forough
    Mosavi, Aslan
    [J]. JOURNAL OF FAMILY MEDICINE AND PRIMARY CARE, 2020, 9 (07) : 3304 - 3307
  • [3] MRI estimation of global brain oxygen consumption rate
    Jain, Varsha
    Langham, Michael C.
    Wehrli, Felix W.
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2010, 30 (09) : 1598 - 1607
  • [4] CEREBRAL BLOOD FLOW AND OXYGEN CONSUMPTION IN MAN
    LASSEN, NA
    [J]. PHYSIOLOGICAL REVIEWS, 1959, 39 (02) : 183 - 238
  • [5] The Use of Bioreactance and Carotid Doppler to Determine Volume Responsiveness and Blood Flow Redistribution Following Passive Leg Raising in Hemodynamically Unstable Patients
    Marik, Paul E.
    Levitov, Alex
    Young, Alisha
    Andrews, Lois
    [J]. CHEST, 2013, 143 (02) : 364 - 370
  • [6] Internal carotid artery blood flow is enhanced by elevating blood pressure during combined propofol-remifentanil and thoracic epidural anaesthesia A randomised cross-over trial
    Olesen, Niels D.
    Frederiksen, Hans-Jorgen
    Storkholm, Jan H.
    Hansen, Carsten P.
    Svendsen, Lars B.
    Olsen, Niels V.
    Secher, Niels H.
    [J]. EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2020, 37 (06) : 482 - 490
  • [7] Common Carotid Artery Sonography Versus Transthoracic Echocardiography for Cardiac Output Measurements in Intensive Care Unit Patients
    Peng, Qian-Yi
    Zhang, Li-Na
    Ai, Mei-Lin
    Li, Li
    Hu, Cheng-Huan
    Zhang, Yan-Xin
    Liu, Wei
    Feng, Qing
    Zou, Yu
    Ai, Yu-Hang
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (09) : 1793 - 1799
  • [8] Color duplex measurement of cerebral blood flow volume in healthy adults
    Scheel, P
    Ruge, C
    Petruch, UR
    Schöning, M
    [J]. STROKE, 2000, 31 (01) : 147 - 150
  • [9] Carotid Flow as a Surrogate for Cardiac Output Measurement in Hemodynamically Stable Participants
    Sidor, Marian
    Premachandra, Lalith
    Hanna, Bishoy
    Nair, Nanda
    Misra, Amit
    [J]. JOURNAL OF INTENSIVE CARE MEDICINE, 2020, 35 (07) : 650 - 655
  • [10] Internal Carotid Artery Blood Flow Response to Anesthesia, Pneumoperitoneum, and Head-up Tilt during Laparoscopic Cholecystectomy
    Skytioti, Maria
    Elstad, Maja
    Sovik, Signe
    [J]. ANESTHESIOLOGY, 2019, 131 (03) : 512 - 520