Application of quality-by-design for adopting an environmentally green fluorogenic determination of benoxinate hydrochloride in eye drops and artificial aqueous humour

被引:20
作者
El Hamd, Mohamed A. A. [1 ,2 ]
El-Maghrabey, Mahmoud [3 ]
Magdy, Galal [4 ]
Mahdi, Wael A. A. [5 ]
Alshehri, Sultan [5 ]
Bass, Amr K. A. [6 ]
Batakoushy, Hany A. A. [7 ]
机构
[1] Shaqra Univ, Coll Pharm, Dept Pharmaceut Sci, Shaqra 11961, Saudi Arabia
[2] South Valley Univ, Fac Pharm, Dept Pharmaceut Analyt Chem, Qena 83523, Egypt
[3] Mansoura Univ, Fac Pharm, Dept Pharmaceut Analyt Chem, Mansoura 35516, Egypt
[4] Kafrelsheikh Univ, Fac Pharm, Pharmaceut Analyt Chem Dept, Kafrelsheikh 33511, Egypt
[5] King Saud Univ, Coll Pharm, Dept Pharmaceut, Riyadh 11451, Saudi Arabia
[6] Menoufia Univ, Fac Pharm, Dept Pharmaceut Chem, Shibin Al Kawm 32511, Egypt
[7] Menoufia Univ, Fac Pharm, Dept Pharmaceut Analyt Chem, Shibin Al Kawm 32511, Egypt
关键词
SPECTROFLUOROMETRIC DETERMINATION; DERIVATIZATION; FLUORESCAMINE; OXYBUPROCAINE; CHEMISTRY; ASSAY;
D O I
10.1038/s41598-023-35347-6
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Herein, a sensitive and selective spectrofluorimetric method has been developed for the determination of the ocular local anesthetic benoxinate hydrochloride (BEN-HCl) in eye drops and artificial aqueous humour. The proposed method is based on the interaction of fluorescamine with the primary amino group of BEN-HCl at room temperature. Following the excitation of the reaction product at 393 nm, the emitted relative fluorescence intensity (RFI) was measured at 483 nm. The key experimental parameters were carefully examined and optimized by adopting an analytical quality-by-design approach. The method used a two-level full factorial design (2(4) FFD) to obtain the optimum RFI of the reaction product. The calibration curve was linear at the range of 0.10-1.0 mu g/mL of BEN-HCl with sensitivity down to 0.015 mu g/mL. The method was applied for analyzing the BEN-HCl eye drops and could also assess its spiked levels in artificial aqueous humour with high % recoveries (98.74-101.37%) and low SD values (<= 1.11). To investigate the green profile of the proposed method, a greenness assessment was performed with the aid of the Analytical Eco-Scale Assessment (ESA) and GAPI. The developed method obtained a very high ESA rating score in addition to being sensitive, affordable, and environmentally sustainable. The proposed method was validated according to ICH guidelines.
引用
收藏
页数:12
相关论文
共 44 条
[1]  
ABDELGAWAD FM, 1995, ANAL LETT, V28, P1437
[2]   Green Chemistry: Principles and Practice [J].
Anastas, Paul ;
Eghbali, Nicolas .
CHEMICAL SOCIETY REVIEWS, 2010, 39 (01) :301-312
[3]   Origins, current status, and future challenges of green chemistry [J].
Anastas, PT ;
Kirchhoff, MM .
ACCOUNTS OF CHEMICAL RESEARCH, 2002, 35 (09) :686-694
[4]  
[Anonymous], 2016, JAPANESE PHARM PHARM
[5]  
[Anonymous], 2013, Recovery Plan for the Black-Footed Ferret (Mustela nigripes), P1
[6]  
[Anonymous], 2008, US PHARMACOPEIAL CON
[7]  
[Anonymous], 2005, ICH HARMONISED TRIPA, VQ2, P1
[8]   Simple and Sensitive Spectrofluorimetric Method for the Determination of Oseltamivir Phosphate in Capsules Through Derivatization with Fluorescamine [J].
Aydogmus, Zeynep .
JOURNAL OF FLUORESCENCE, 2009, 19 (04) :673-679
[9]   Spectrofluorimetric determination of vigabatrin and gabapentin in urine and dosage forms through derivatization with fluorescamine [J].
Belal, F ;
Abdine, H ;
Al-Majed, A ;
Khalil, NY .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 27 (1-2) :253-260
[10]  
Brayfield A., 2013, Martindale: The Complete Drug Reference