Posterior capsule dynamics during femtosecond laser lens fragmentation

被引:1
作者
Bellucci, Carlo [1 ]
Mora, Paolo [1 ]
Tedesco, Salvatore Antonio [1 ]
Bellucci, Roberto [2 ]
Gandolfi, Stefano [1 ]
机构
[1] Univ Parma, Dept Med & Surg, Ophthalmol Unit, Via Gramsci 14, I-43126 Parma, Italy
[2] Vista Vis Surg Ctr, Verona, Italy
关键词
Cataract surgery; Femtosecond laser; Posterior capsule rupture; Posterior capsule dynamics; ASSISTED CATARACT-SURGERY;
D O I
10.1007/s10792-023-02739-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeThe dynamics of the posterior capsule during femtosecond laser lens fragmentation has received little attention in the literature. We analysed the movements of the posterior capsule to identify the rupture risk factors, if any, and to suggest possible modification of the laser spot energy pattern during fragmentation.Materials and methodsPosterior capsule ruptures during fragmentation were identified over a 10-year period of femtosecond laser use. In addition, the dynamics of the posterior capsule were identified through the real-time swept-source OCT lateral view available during the surgeries.ResultsOut of the 1465 laser cataract procedures performed, we recorded 1 case of posterior capsule rupture during lens fragmentation, which was caused by eye movement that was detected but ignored by the surgeon. Three types of posterior capsule dynamics were identified, all related to a gas bubble formation during the first part of the lens fragmentation. In eyes with a hard nucleus, the concussion of the posterior capsule was evident, however, with no capsule rupture.DiscussionMaintaining good docking throughout the whole procedure seems important in avoiding a posterior capsule cut by the femtosecond laser. In addition, a Gaussian pattern of spot energy is suggested when fragmenting hard cataracts.
引用
收藏
页码:3339 / 3343
页数:5
相关论文
共 50 条
  • [31] Analysis of micro lens fabrication via femtosecond laser
    Xiao, SZ
    Guo, R
    Huang, WH
    Xia, AD
    [J]. 2ND INTERNATIONAL CONFERENCE ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: ADVANCED OPTICAL MANUFACTURING TECHNOLOGIES, 2006, 6149
  • [32] Dynamics of femtosecond laser interactions with dielectrics
    S.S. Mao
    F. Quéré
    S. Guizard
    X. Mao
    R.E. Russo
    G. Petite
    P. Martin
    [J]. Applied Physics A, 2004, 79 : 1695 - 1709
  • [33] Impact of lens density and lens thickness on cumulative dissipated energy in femtosecond laser-assisted cataract surgery
    Shajari, Mehdi
    Rusev, Vladimir
    Mayer, Wolfgang
    Diakonis, Vasilios
    Petermann, Kerstin
    Kohnen, Thomas
    [J]. LASERS IN MEDICAL SCIENCE, 2019, 34 (06) : 1229 - 1234
  • [34] Fixation of an intraocular lens using reverse optic capture with haptic tuck for intraoperative posterior capsule rupture
    Khoramnia, Ramin
    Wallek, Hannah
    Gungor, Helin
    Yildirim, Timur M.
    Auffarth, Gerd U.
    Mayer, Christian S.
    [J]. OPHTHALMOLOGE, 2021, 118 (09): : 960 - 964
  • [35] Photostimulation by femtosecond laser triggers restorable fragmentation in single mitochondrion
    Wang, Yintao
    He, Hao
    Wang, Shaoyang
    Liu, Yaohui
    Hu, Minglie
    Cao, Youjia
    Kong, Siukai
    Wei, Xunbin
    Wang, Chingyue
    [J]. JOURNAL OF BIOPHOTONICS, 2017, 10 (02) : 286 - 293
  • [36] Randomized intraindividual comparison of posterior capsule opacification between a microincision intraocular lens and a conventional intraocular lens
    Cleary, Georgia
    Spalton, David J.
    Hancox, Joanne
    Boyce, James
    Marshall, John
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (02) : 265 - 272
  • [37] Glued intraocular lens scaffolding to create an artificial posterior capsule for nucleus removal in eyes with posterior capsule tear and insufficient iris and sulcus support
    Agarwal, Amar
    Jacob, Soosan
    Agarwal, Ashvin
    Narasimhan, Smita
    Kumar, Dhivya Ashok
    Agarwal, Athiya
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (03) : 326 - 333
  • [38] Influence on posterior capsule opacification and visual function of Intraocular lens optic material
    Hayashi, Ken
    Hayashi, Hideyuki
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (02) : 195 - 202
  • [39] Cytoskeletal drugs prevent posterior capsular opacification in human lens capsule in vitro
    Sureshkumar, Jeyalakshmi
    Haripriya, Aravind
    Muthukkaruppan, Veerappan
    Kaufman, Paul L.
    Tian, Baohe
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 250 (04) : 507 - 514
  • [40] Accuracy of 10 MHz ultrasonography for evaluation of posterior lens capsule in traumatic cataract
    Ke, Xixuan
    Li, Cuilian
    Lin, Liyu
    Huang, Yuqiang
    Xia, Honghe
    Jin, Chuang
    Shi, Tingkun
    Zhang, Qi
    Liao, Xulong
    Chen, Haoyu
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (11) : 3629 - 3634