Upconversion nanoparticle-based aptasensor for rapid and ultrasensitive detection of Staphylococcus aureus by low-speed centrifugation

被引:8
|
作者
Li, Na [1 ]
Zhang, Ying [1 ,2 ]
Wei, Tiancheng [1 ]
Yang, Tao [3 ]
Bao, Qing [3 ]
Cheng, Qichao [1 ]
Mao, Chuanbin [3 ]
Shuai, Yajun [1 ]
Yang, Mingying [1 ]
机构
[1] Zhejiang Univ, Inst Appl Bioresource Res, Coll Anim Sci, Zhejiang Prov Key Lab Utilizat & Innovat Silkworm, Hangzhou, Peoples R China
[2] Westlake Univ, Sch Life Sci, Hangzhou 310024, Zhejiang, Peoples R China
[3] Zhejiang Univ, Sch Mat Sci & Engn, Hangzhou 310058, Peoples R China
基金
美国国家科学基金会;
关键词
APTAMERS;
D O I
10.1039/d3ra01555f
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Opportunistic foodborne pathogens such as Staphylococcus aureus (S. aureus) can cause a wide variety of threats to public health. There is an urgent clinical need for a fast, simple, low-cost, and sensitive method. Here, we designed a fluorescence-based aptamer biosensor (aptasensor) for S. aureus detection using core-shell structured upconversion nanoparticles (CS-UCNPs) as a beacon. A S. aureus-specific aptamer was modified on the surface of CS-UCNPs for binding pathogens. The S. aureus bound to CS-UCNPs can then be isolated from the detection system by simple low-speed centrifugation. Thus, an aptasensor was successfully established for the detection of S. aureus. The fluorescence intensity of CS-UCNPs correlated with the concentration of S. aureus within the range of 6.36 x 10(2) to 6.36 x 10(8) CFU mL(-1), resulting in the detected limit of S. aureus being 60 CFU mL(-1). The aptasensor performed well in real food samples (milk) with a detection limit of 146 CFU mL(-1) for S. aureus. Furthermore, we applied our aptasensor in chicken muscles for S. aureus detection, and compared it with the plate count gold standard method. There was no significant difference between our aptasensor and the plate count method within the detected limit, while the time for the aptasensor (0.58 h) was shorter than that of the plate count method (3-4 d). Therefore, we succeeded in the design of a simple, sensitive and fast CS-UCNPs aptasensor for S. aureus detection. This aptasensor system would have the potential for the detection of a wide range of bacterial species by switching the corresponding aptamer.
引用
收藏
页码:20229 / 20234
页数:6
相关论文
共 50 条
  • [41] Gold nanoparticle-based immunochromatographic test for identification of Staphylococcus aureus from clinical specimens
    Huang, Su-Hua
    CLINICA CHIMICA ACTA, 2006, 373 (1-2) : 139 - 143
  • [42] A Gold Nanoparticle-Based Cortisol Aptasensor for Non-Invasive Detection of Fish Stress
    Tanaka, Yuki
    Salleh, Nur Asinah binte Mohamed
    Tan, Marie Ruoyun
    Vij, Shubha
    Wee, Caroline Lei
    Sutarlie, Laura
    Su, Xiaodi
    BIOMOLECULES, 2024, 14 (07)
  • [43] An ultrasensitive sandwich-type electrochemical aptasensor using silver nanoparticle/titanium carbide nanocomposites for the determination of Staphylococcus aureus in milk
    Hui, Yuanyuan
    Peng, Haishuai
    Zhang, Fuxin
    Zhang, Lei
    Liu, Yufang
    Jia, Rong
    Song, Yuxuan
    Wang, Bini
    MICROCHIMICA ACTA, 2022, 189 (08)
  • [44] Smartphone enabled upconversion nanoparticle-based lateral flow strip for ultra-low concentration of methamphetamine detection
    Wang, Wei
    Ye, Zihan
    Ma, Xing
    Guo, Jinhong
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 370
  • [45] Gold nanoparticle-based immunochromatographic assay for rapid detection of imazalil
    Xu, Xinxin
    Wu, Aihong
    Guo, Lingling
    Kuang, Hua
    Xu, Liguang
    Xu, Chuanlai
    Liu, Liqiang
    NANOSCALE HORIZONS, 2023, 9 (01) : 123 - 131
  • [46] A sensitive gold nanoparticle-based aptasensor for colorimetric detection of Aβ1-40 oligomers
    Zhu, Xu
    Zhang, Ningning
    Zhang, Yintang
    Liu, Baoxia
    Chang, Zhu
    Zhou, Yanli
    Hao, Yuanqiang
    Ye, Baoxian
    Xu, Maotian
    ANALYTICAL METHODS, 2018, 10 (06) : 641 - 645
  • [47] An ultrasensitive sandwich-type electrochemical aptasensor using silver nanoparticle/titanium carbide nanocomposites for the determination of Staphylococcus aureus in milk
    Yuanyuan Hui
    Haishuai Peng
    Fuxin Zhang
    Lei Zhang
    Yufang Liu
    Rong Jia
    Yuxuan Song
    Bini Wang
    Microchimica Acta, 2022, 189
  • [48] Detection of methicillin-resistant Staphylococcus aureus using a gold nanoparticle-based colourimetric polymerase chain reaction assay
    Chan, Wai-Sing
    Tang, Bone S. F.
    Boost, Maureen V.
    Chow, Chit
    Leung, Polly H. M.
    BIOSENSORS & BIOELECTRONICS, 2014, 53 : 105 - 111
  • [49] Rapid and low-cost biosensor for the detection of Staphylococcus aureus
    Suaifan, Ghadeer A. R. Y.
    Alhogail, Sahar
    Zourob, Mohammed
    BIOSENSORS & BIOELECTRONICS, 2017, 90 : 230 - 237
  • [50] Visual upconversion nanoparticle-based immunochromatographic assay for the semi-quantitative detection of sibutramine
    Shi-Wei Zhang
    Yan-Yan Sun
    Yuan-Ming Sun
    Hong Wang
    Zhen-Feng Li
    Zhen-Lin Xu
    Analytical and Bioanalytical Chemistry, 2020, 412 : 8135 - 8144