Objectives The purpose of this in vitro study was to assess and compare the marginal and internal fit of machine-milled crowns designed using three different CAD software programs. Materials and methods Digital impressions of the master zirconia casts containing the prepared molar were obtained using an intraoral scanner. The obtained standard tessellation language (STL) files were imported into three CAD software programs (Multi-CAD, Blue-Sky CAD, and InLab), and crown designs were generated. Crown design digital STL files were used to mill crowns with a five-axis dental milling machine. The internal and marginal fits of the fabricated crowns over the master-prepared tooth were assessed using the triple-scan protocol and digital analysis techniques. The 3D marginal and internal fit values of the fabricated crowns from the designs generated by the three CAD programs were evaluated and statistically compared using one-way analysis of variance (ANOVA) and post hoc Tukey's tests (alpha = 0.05). Results There were no significant differences in the internal fit of the crowns designed by the three CAD programs (p > 0.05). However, there were significant differences in the mean marginal fit (p = 0.009) of the crowns. The marginal fit values for the InLab-designed crowns were significantly better than those for Multi-CAD (p = 0.03) and Blue-Sky CAD (p = 0.012) groups. Conclusions All three CAD programs can design clinically acceptable crowns in terms of internal and marginal fit. InLab crowns outperformed the Multi-CAD and Blue-Sky CAD programs in terms of marginal fit.
引用
收藏
页码:263 / 271
页数:9
相关论文
共 50 条
  • [41] In Vitro Study of Comparative Evaluation of Marginal and Internal Fit between Heat-Pressed and CAD-CAM Monolithic Glass-Ceramic Restorations after Thermal Aging
    Vasiliu, Roxana-Diana
    Porojan, Sorin Daniel
    Porojan, Liliana
    MATERIALS, 2020, 13 (19)
  • [42] Evaluation of the marginal fit of metal copings fabricated by using 3 different CAD-CAM techniques: Milling, stereolithography, and 3D wax printer
    Khaledi, Amir-Alireza
    Farzin, Mitra
    Akhlaghian, Marzieh
    Pardis, Soheil
    Mir, Negar
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (01) : 81 - 86
  • [43] Three-dimensional evaluation of marginal and internal fit of 3D-printed interim restorations fabricated on different finish line designs
    Alharbi, Nawal
    Alharbi, Saud
    Cuijpers, Vincent M. J. I.
    Osmane, Reham B.
    Wismeijer, Daniel
    JOURNAL OF PROSTHODONTIC RESEARCH, 2018, 62 (02) : 218 - 226
  • [44] Effect of Different CAD/CAM Milling and 3D Printing Digital Fabrication Techniques on the Accuracy of PMMA Working Models and Vertical Marginal Fit of PMMA Provisional Dental Prosthesis: An In Vitro Study
    Sidhom, Marina
    Zaghloul, Hanaa
    Mosleh, Ihab El-Sayed
    Eldwakhly, Elzahraa
    POLYMERS, 2022, 14 (07)
  • [45] Evaluation of the Marginal Fit of Computer-Aided Design (CAD) and Computer-Aided Manufacturing (CAM) Zirconia Bridges Fabricated With Different Firing Cycles of Veneering Porcelain: An In Vitro Study
    Chokr, Hawraa
    Alshaarani, Fendi
    Husein, Hassan A.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (02)
  • [46] Marginal fit of 3-unit CAD-CAM zirconia frameworks fabricated using cone beam computed tomography scans: an experimental study
    Belgin, Huseyin Berkay
    Kale, Ediz
    Ozcelik, Tuncer Burak
    Yilmaz, Burak
    ODONTOLOGY, 2022, 110 (02) : 339 - 348
  • [47] Evaluation of the marginal fit of lithium disilicate single crowns fabricated with the conventional (IPS e.max Press) and CAD/CAM (IPS e.max CAD) methods: a systematic review and meta-analysis
    Pachiou, Aspasia
    Zervou, Evangelia
    Tsirogiannis, Panagiotis
    Sykaras, Nikitas
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2024, 27 (04)
  • [48] Comparison of marginal and internal fit of three-unit implant-supported fixed prosthetic substructures fabricated using CAD/CAM systems
    Ozlem Kayikci
    Sabit Melih Ates
    Clinical Oral Investigations, 2022, 26 : 1283 - 1291
  • [49] The Influence of Three Different Digital Cement Spacers on the Marginal Gap Adaptation of Zirconia-Reinforced Lithium Silicate Crowns Fabricated by CAD-CAM System
    Ben-Izhack, Gil
    Shely, Asaf
    Naishlos, Sarit
    Glikman, Ari
    Frishman, Liad
    Meirowitz, Avi
    Dolev, Eran
    APPLIED SCIENCES-BASEL, 2021, 11 (22):
  • [50] Comparative evaluation of marginal fit accuracy of two different designs of endocrown manufactured through CAD-CAM system: An in vitro study
    Gupta, Khushbu Rakesh
    Gupta, Deepesh Kumar
    Jha, Anumeha
    Shukla, Shivam B.
    Dubey, Aayush Mukund
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2025, 25 (01) : 74 - 79