Evaluation of the marginal and internal fit of CAD/CAM crowns designed using three different dental CAD programs: a 3-dimensional digital analysis study

被引:6
|
作者
Farah, Ra'fat, I [1 ]
Alresheedi, Bandar [1 ]
机构
[1] Qassim Univ, Coll Dent, Dept Prosthet Dent Sci, POB 6700, Al Mulaydah 51452, Qassim, Saudi Arabia
关键词
CAD; CAM; Computer-aided design; Internal fit; Marginal fit; Triple-scan protocol; ACCURACY; TECHNOLOGY; SYSTEMS; COPINGS; SPACE;
D O I
10.1007/s00784-022-04720-6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives The purpose of this in vitro study was to assess and compare the marginal and internal fit of machine-milled crowns designed using three different CAD software programs. Materials and methods Digital impressions of the master zirconia casts containing the prepared molar were obtained using an intraoral scanner. The obtained standard tessellation language (STL) files were imported into three CAD software programs (Multi-CAD, Blue-Sky CAD, and InLab), and crown designs were generated. Crown design digital STL files were used to mill crowns with a five-axis dental milling machine. The internal and marginal fits of the fabricated crowns over the master-prepared tooth were assessed using the triple-scan protocol and digital analysis techniques. The 3D marginal and internal fit values of the fabricated crowns from the designs generated by the three CAD programs were evaluated and statistically compared using one-way analysis of variance (ANOVA) and post hoc Tukey's tests (alpha = 0.05). Results There were no significant differences in the internal fit of the crowns designed by the three CAD programs (p > 0.05). However, there were significant differences in the mean marginal fit (p = 0.009) of the crowns. The marginal fit values for the InLab-designed crowns were significantly better than those for Multi-CAD (p = 0.03) and Blue-Sky CAD (p = 0.012) groups. Conclusions All three CAD programs can design clinically acceptable crowns in terms of internal and marginal fit. InLab crowns outperformed the Multi-CAD and Blue-Sky CAD programs in terms of marginal fit.
引用
收藏
页码:263 / 271
页数:9
相关论文
共 50 条
  • [21] Evaluation of marginal and internal fit of lithium disilicate CAD-CAM crowns with different finish lines by using a micro-CT technique
    Rizonaki, Maria
    Jacquet, Wolfgang
    Bottenberg, Peter
    Depla, Lennert
    Boone, Matthieu
    De Coster, Peter J.
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (06) : 890 - 898
  • [22] An in vitro evaluation of marginal fit zirconia crowns fabricated by a CAD-CAM dental laboratory and a milling center
    Avi Meirowitz
    Yoli Bitterman
    Sharon Levy
    Eitan Mijiritsky
    Eran Dolev
    BMC Oral Health, 19
  • [23] Marginal and internal fit of curved anterior CAD/CAM-milled zirconia fixed dental prostheses: An in-vitro study
    Buechi, Dominik L.
    Ebler, Sabine
    Haemmerle, Christoph H. F.
    Sailer, Irena
    QUINTESSENCE INTERNATIONAL, 2014, 45 (10): : 837 - 846
  • [24] Comparison of marginal adaptation and internal fit of monolithic lithium disilicate crowns produced by 4 different CAD/CAM systems
    Brunna Mota Ferrairo
    Fernanda Furtado Piras
    Feranda Ferruzzi Lima
    Heitor Marques Honório
    Marco Antonio Hungaro Duarte
    Ana Flávia Sanches Borges
    José Henrique Rubo
    Clinical Oral Investigations, 2021, 25 : 2029 - 2036
  • [25] Evaluation of Marginal and Internal Adaptation of Endocrowns Fabricated from Three Different CAD/CAM Materials
    Hasanzade, Mahya
    Moharrami, Mohammad
    Alikhasi, Marzieh
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2019, 27 (04) : 164 - 171
  • [26] Comparison of the marginal fit of lithium disilicate crowns fabricated with CAD/CAM technology by using conventional impressions and two intraoral digital scanners
    Abdel-Azim, Tamer
    Rogers, Kelly
    Elathamna, Eiad
    Zandinejad, Amirali
    Metz, Michael
    Morton, Dean
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (04) : 554 - 559
  • [27] Marginal fit of anterior 3-unit fixed partial zirconia restorations using different CAD/CAM systems
    Song, Tae-Jin
    Kwon, Taek-Ka
    Yang, Jae-Ho
    Han, Jung-Suk
    Lee, Jai-Bong
    Kim, Sung-Hun
    Yeo, In-Sung
    JOURNAL OF ADVANCED PROSTHODONTICS, 2013, 5 (03) : 219 - 225
  • [28] Comparison of marginal and internal fit of 5-unit zirconia fixed dental prostheses fabricated with CAD/CAM technology using direct and indirect digital scans
    Uluc, Irem Gokce
    Guncu, Mustafa Baris
    Aktas, Guliz
    Turkyilmaz, Ilser
    JOURNAL OF DENTAL SCIENCES, 2022, 17 (01) : 63 - 69
  • [29] Marginal and Internal Fit of Ceramic Prostheses Fabricated from Different Chairside CAD/CAM Systems: An In Vitro Study
    Son, Keunbada
    Lee, Kyu-Bok
    APPLIED SCIENCES-BASEL, 2021, 11 (02): : 1 - 13
  • [30] SEM Evaluation of the Marginal Accuracy of Zirconia, Lithium Disilicate, and Composite Single Crowns Created by CAD/CAM Method: Comparative Analysis of Different Materials
    Ferrini, Francesco
    Paolone, Gaetano
    Di Domenico, Giovanna Laura
    Pagani, Nicolo
    Gherlone, Enrico Felice
    MATERIALS, 2023, 16 (06)