An Enhanced Parameter-Free Fault Locator for Untransposed Line With Unsynchronized Terminals

被引:1
|
作者
Kalita, Kaustav [1 ,2 ]
Anand, Shubham [3 ]
Parida, S. K. [3 ]
机构
[1] Power Grid Corp India Ltd, Gurgaon 122001, India
[2] Indian Inst Technol, Patna 801106, Bihar, India
[3] Indian Inst Technol, Dept Elect Engn, Patna 801106, Bihar, India
关键词
Fault location; untransposed configuration; two-terminal line; unsynchronized measurements; impedance and admittance matrix;
D O I
10.1109/TPWRD.2023.3295998
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This letter presents a novel fault location algorithm for single circuit untransposed line, which is independent of transmission line parameters and unsynchronized measurement. The novelty of proposed algorithm is that it considers asymmetry in untransposed line while considering unequal angles of synchronism mismatch in pre-fault and fault conditions. Thus, in contrast to existing techniques the proposed algorithm can be applied to conductor configuration other than delta/flat configuration of untransposed line. Simulation results using EMTP-RV platform along with those obtained using field data are presented. The test results verify the accuracy and validity of the proposed method.
引用
收藏
页码:3733 / 3736
页数:4
相关论文
共 20 条
  • [11] A Closed Form Solution for Line Parameter-Less Fault Location With Unsynchronized Measurements
    Kalita, Kaustav
    Anand, Shubham
    Parida, S. K.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (03) : 1997 - 2006
  • [12] Line Parameter-Free Fault Location Algorithm for Series Compensated Transmission Lines
    Padmanabhan, Shantanu
    Terzija, Vladimir
    2013 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PES), 2013,
  • [13] Parameter-Less Fault Locator for Double-Circuit Transmission Line Using Two-Terminal Unsynchronized Measurements
    Saber, Ahmed
    Zeineldin, H. H.
    El-Saadany, Ehab F.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2024, 39 (05) : 2616 - 2629
  • [14] Unsynchronized Parameter-Free Fault Location for Two or Three Terminal Double-Circuit Transmission Lines Sharing the Same Tower via Unscented Kalman Filter
    Wang, Binglin
    Liu, Yu
    Lu, Dian
    Yue, Kang
    Nie, Yuan
    IEEE TRANSACTIONS ON POWER DELIVERY, 2023, 38 (03) : 1731 - 1746
  • [15] Distributed Parameter Based Setting-Free Fault Locator for Double-Circuit Line Using Fault Data
    Kalita, Kaustav
    Anand, Shubham
    Parida, S. K.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2023, 38 (04) : 2981 - 2984
  • [16] A new parameter-free fault location approach for power distribution systems
    Hamdouche, Tarek
    Boushaki, Saida Ishak
    Bendjeghaba, Omar
    Brakta, Noureddine
    COMPUTERS & ELECTRICAL ENGINEERING, 2023, 111
  • [17] Parameter-free Fault Location Algorithm for Multi-terminal Overhead Transmission Line of Distribution Network Based on μMPMU
    Wang C.
    Yun Z.
    Zhang H.
    Shi F.
    Ling P.
    Xie B.
    Dianwang Jishu/Power System Technology, 2019, 43 (09): : 3202 - 3209
  • [18] New Parameter-Free Fault Location Algorithm for Transmission Lines in Phasor Domain
    Padmanabhan, S.
    Terzija, V.
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [19] Parameter-Free Fault Location Algorithm for Distribution Network T-Type Transmission Lines
    Wang, Chengbin
    Yun, Zhihao
    ENERGIES, 2019, 12 (08)
  • [20] Parameter-Less Fault Locator using Synchronized/Un-Synchronized Data for Overhead Transmission Line
    Keshri, Jay Prakash
    Tiwari, Harpal
    2017 INTERNATIONAL CONFERENCE ON COMPUTER, COMMUNICATIONS AND ELECTRONICS (COMPTELIX), 2017, : 260 - 264