Investigation on pitting corrosion mechanism of the Fe-based amorphous alloy coating by three-dimensional X-ray imaging at micro-scale

被引:2
|
作者
Wang, Mengru [1 ]
Zhong, Yan [2 ]
Liang, Dandan [3 ]
Liu, Tao [4 ]
Wei, Xianshun [1 ]
Zhang, Yongming [1 ]
Chen, Bo [1 ]
机构
[1] Tongji Univ, Sch Mat Sci & Engn, Key Lab Adv Civil Engn Mat, Minist Educ, Shanghai 201804, Peoples R China
[2] Shanghai Highway Investment Construct & Dev Co Ltd, Shanghai 200336, Peoples R China
[3] Superhard Coating & Equipment Shanghai Inst Tech, Shanghai Engn Res Ctr Phys Vapor Deposit PVD, Shanghai, Peoples R China
[4] Tongji Univ, Coll Civil Engn, Shanghai 200092, Peoples R China
来源
JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T | 2023年 / 26卷
基金
中国国家自然科学基金;
关键词
Fe-based amorphous alloy coating; (Fe-based AAC); Corrosion behavior; X-ray micro-computed tomography; (X-ray micro-CT); Three-dimensional analysis; Pitting corrosion; BULK METALLIC-GLASS; LOCALIZED CORROSION; STAINLESS-STEEL; RESISTANCE; BEHAVIOR; MICROTOMOGRAPHY; INITIATION; ROUGHNESS; KINETICS; GROWTH;
D O I
10.1016/j.jmrt.2023.09.026
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Few work have been performed regarding the quantitative characterization of threedimensional (3D) pitting corrosion process directly, although the corrosion behaviors and the passivation film stability of metals in various solutions have been studied heavily. The reported work quantitatively characterized the 3D pitting corrosion of the Fe-based amorphous alloy coating (Fe-based AAC) via X-ray micro-computed tomography (X-ray micro-CT) and further elucidated the mechanism of its pitting corrosion. Moreover, the microstructure and electrochemical performance of the Fe-based AAC have also been explored. The results showed that the targeted thermal sprayed Fe43Cr20Mo10W4C15B6Y2 coating was prone to be corroded with the increase of the hydrogen ion concentration, i.e. higher hydrogen ion concentration leads to poorer corrosion performance of the Fe-based AAC. The X-ray micro-CT results revealed that the pits in the Fe-based AAC initially nucleated below the pitting potential, and they also generated in the over-passivation stage. Furthermore, it was found that the corrosive medium does not penetrate into the coating/substrate interface, and the deduced corrosion mechanism from the findings was also discussed.(c) 2023 The Author(s). Published by Elsevier B.V. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:6405 / 6418
页数:14
相关论文
共 14 条
  • [1] Micro-scale corrosion behaviours of the Fe-based amorphous alloy coating in alkaline solutions in three-dimensions
    Hairule, Yiliyaer
    Liang, Dandan
    Chen, Tiantian
    Zhang, Yongming
    Wei, Xianshun
    Chen, Qing
    Li, Wen
    Chen, Bo
    JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2025, 35 : 2984 - 2993
  • [2] Investigation of nano- and micro-scale structural evolution and resulting corrosion resistance in plasma sprayed Fe-based (Fe-Cr-B-C-P) amorphous coatings
    Kumar, Anil
    Nayak, Sapan Kumar
    Sarkar, Kuntal
    Banerjee, Atanu
    Mondal, Kallol
    Laha, Tapas
    SURFACE & COATINGS TECHNOLOGY, 2020, 397
  • [3] Three-dimensional microstructural investigation of high magnetization nano-micro composite fluids using x-ray microcomputed tomography
    Borbath, T.
    Borbath, I.
    Guenther, S.
    Marinica, O.
    Vekas, L.
    Odenbach, S.
    SMART MATERIALS AND STRUCTURES, 2014, 23 (05)
  • [4] In-situ three-dimensional X-ray investigation on micro ductile fracture mechanism of a high-Mn steel with delayed necking effect
    Jia, Liang-Jiu
    Zhang, Rui
    Zhou, Chang-Feng
    Gu, Tian-Yu
    Liu, Tao
    Xie, Jin-Bao
    He, Man-Chao
    Xia, Min
    Chen, Bo
    JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2023, 24 : 1076 - 1087
  • [5] Three-dimensional reconstruction of maize roots and quantitative analysis of metaxylem vessels based on X-ray micro-computed tomography
    Pan, Xiaodi
    Ma, Liming
    Zhang, Ying
    Wang, Jinglu
    Du, Jianjun
    Guo, Xinyu
    CANADIAN JOURNAL OF PLANT SCIENCE, 2018, 98 (02) : 457 - 466
  • [6] An investigation on the three-dimensional transport of chloride ions in concrete based on X-ray computed tomography technology
    Tian, Ye
    Chen, Changchang
    Jin, Nanguo
    Jin, Xianyu
    Tian, Zushi
    Yan, Dongming
    Yu, Wei
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 221 : 443 - 455
  • [7] Synchrotron X-ray microtomography (on a micron scale) provides three-dimensional imaging representation of bone ingrowth in calcium phosphate biomaterials
    Weiss, P
    Obadia, L
    Magne, D
    Bourges, X
    Rau, C
    Weitkamp, T
    Khairoun, I
    Bouler, JM
    Chappard, D
    Gauthier, O
    Daculsi, G
    BIOMATERIALS, 2003, 24 (25) : 4591 - 4601
  • [8] A three-dimensional meso-scale approach to concrete fracture based on combined DEM with X-ray CT images
    Nitka, M.
    Tejchman, J.
    CEMENT AND CONCRETE RESEARCH, 2018, 107 : 11 - 29
  • [9] Particle Coagulation in Molten Metal Based on Three-Dimensional Analysis of Cluster by X-Ray Micro-Computer Tomography (CT)
    Li, Tao
    Shimasaki, Shin-ichi
    Taniguchi, Shoji
    Uesugi, Kentaro
    Narita, Shunsuke
    ISIJ INTERNATIONAL, 2013, 53 (11) : 1958 - 1967
  • [10] Particle Coagulation in Molten Metal Based on Three-Dimensional Analysis of Cluster by X-Ray Micro-Computer Tomography (CT)
    Li, Tao
    Shimaski, Shin-ichi
    Taniguchi, Shoji
    Uesugi, Kentaro
    Narita, Shunsuke
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 2015, 101 (02): : 158 - 167