Analysis of a Hybrid System Solar Chimney-Air Soil Heat Exchanger for Natural Ventilation

被引:0
作者
Belfegas, Billal [1 ,2 ]
Tayebi, Tahar [2 ]
Larbi, Salah [1 ]
机构
[1] Natl Polytech Sch, Mech Engn & Dev Lab, Algiers 1,10 Ave Hassen Badi, Algiers 16200, Algeria
[2] Univ Mohamed El Bachir El Ibrahimi Bordj Bou Arrer, Fac Sci & Technol, Dept Mech Engn, El Anasser 34030, Algeria
关键词
Natural ventilation; Solar chimney; Heat exchanger; PERFORMANCE; BUILDINGS;
D O I
10.4028/p-3elgVg
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The current study looks at a hybrid passive cooling system that combines a solar chimney with an earth-to-air heat exchanger (EAHE) usually called Canadian Well. Numerous experimental and numerical examinations with various applied radiation heat fluxes were carried out to evaluate its ability to cool a room. Glass temperature, wall temperature, air flow mean temperature, hourly rate of air exchange (ACH), outlet airflow velocity, and rate of air mass flow were determined experimentally and numerically, and validated against previously published experimental and analytical works. It was found that the chimney's operation is dependent on the radiation intensity. The EAHE has reduced the room's temperature by improving exchanges with the solar chimney. The comparison of experimental and numerical data for different radiation intensities reveals that the best diameter of the tube of the underground heat exchanger for the proper operation of our system is 0.04 m. The efficiency of our system increases as the radiation increases, causing an increase in the temperature of the absorber, which influences the air temperature in the chimney.
引用
收藏
页码:91 / 110
页数:20
相关论文
共 16 条
[1]   Improving night ventilation into low-rise buildings in hot-arid climates exploring a combined wall-roof solar chimney [J].
AboulNaga, MM ;
Abdrabboh, SN .
RENEWABLE ENERGY, 2000, 19 (1-2) :47-54
[2]   Performance investigation of an original hybrid solar facade system used for HDH desalination and building natural ventilation [J].
Alimi, Sonia ;
Nciri, Rached ;
Nasri, Faouzi ;
Rothan, Yahya Ali ;
Ali, Chaouki .
JOURNAL OF BUILDING ENGINEERING, 2021, 42
[3]   SOLAR CHIMNEY FOR ENHANCED STACK VENTILATION [J].
BANSAL, NK ;
MATHUR, R ;
BHANDARI, MS .
BUILDING AND ENVIRONMENT, 1993, 28 (03) :373-377
[4]   Innovative integration of solar chimney ventilator, solar panel and phase change material; under real transient weather condition of Hong Kong through different months [J].
Cao, Yan ;
Sinaga, Nazaruddin ;
Pourhedayat, Samira ;
Dizaji, Hamed Sadighi .
RENEWABLE ENERGY, 2021, 174 :865-878
[5]   An experimental work on the impact of new combinations of solar chimney, photovoltaic and geothermal air tube on building cooling and ventilation [J].
Elghamry, Rania ;
Hassan, Hamdy .
SOLAR ENERGY, 2020, 205 :142-153
[6]   Solar ventilation and heating of buildings in sunny winter days using solar chimney [J].
Haghighi, A. P. ;
Maerefat, M. .
SUSTAINABLE CITIES AND SOCIETY, 2014, 10 :72-79
[7]   Effects of the geometrical and operational parameters and alternative outer cover materials on the performance of solar chimney used for natural ventilation [J].
Hosien, M. A. ;
Selim, S. M. .
ENERGY AND BUILDINGS, 2017, 138 :355-367
[8]   A CFD based approach for determining the optimum inclination angle of a roof-top solar chimney for building ventilation [J].
Kong, Jing ;
Niu, Jianlei ;
Lei, Chengwang .
SOLAR ENERGY, 2020, 198 :555-569
[9]   Experimental investigations on solar chimney for room ventilation [J].
Mathur, Jyotirmay ;
Bansal, N. K. ;
Mathur, Sanjay ;
Jain, Meenakshi ;
Anupma .
SOLAR ENERGY, 2006, 80 (08) :927-935
[10]   Summer-performance of inclined roof solar chimney for natural ventilation [J].
Mathur, Jyotirmay ;
Mathur, Sanjay ;
Anupma .
ENERGY AND BUILDINGS, 2006, 38 (10) :1156-1163