Biliary self-expandable metallic stent combined with iodine-125 seeds in the treatment of malignant biliary obstruction (Bismuth type I or II)

被引:2
作者
Chai, Jie [1 ]
Liu, Kaicai [2 ]
Xu, Beibei [1 ]
Wang, Lijun [1 ]
Yu, Huafeng [1 ]
Lv, Weifu [1 ]
Lu, Dong [1 ]
机构
[1] Univ Sci & Technol China, Affiliated Hosp USTC 1, Dept Intervent Radiol, Div Life Sci & Med, 17 Lujiang Rd, Hefei 230001, Anhui, Peoples R China
[2] Univ Sci & Technol China, Infect Hosp, Affiliated Hosp USTC 1, Div Life Sci & Med, Hefei 230022, Anhui, Peoples R China
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2023年 / 37卷 / 10期
关键词
Self-expandable metallic stent; Malignant biliary obstruction; I-125; seeds; Radioactive material; Tumor; IMPLANTATION; BRACHYTHERAPY; PLACEMENT; DRAINAGE; SAFETY; PALLIATION; EFFICACY; STRAND;
D O I
10.1007/s00464-023-10327-z
中图分类号
R61 [外科手术学];
学科分类号
摘要
BackgroundThe purpose of this research was to evaluate the safety and efficacy of a self-expandable metallic stent (SEMS) combined with iodine-125 (I-125) seeds in the treatment of Bismuth type I or II malignant biliary obstruction (MBO).MethodsThe clinical data of 74 cases of MBO treated with percutaneous SEMS combined with I-125 seeds (combination group) and 81 cases of MBO treated with SEMS implantation alone (control group) in our hospital from January 2015 to December 2019 were retrospectively analyzed. The short-term and long-term efficacy of the two groups were compared. Multivariate Cox regression analysis was used to analyze the factors affecting the surgical efficacy and survival rate.ResultsThe liver blood test results of both groups improved at one week and one month post-stent insertion. No significant difference was established in the short-term efficacy or complications between the two groups (P = NS). Improved stent patency was observed in the combined group, 9.01 & PLUSMN; 4.38 months versus 6.79 & PLUSMN; 3.13 months, respectively (P < 0.001). Improved survival was also noted in the combined group 12.08 & PLUSMN; 5.38 months and 9.10 & PLUSMN; 4.16 months, respectively (P < 0.001). Univariate and multivariate analyses showed that the type of biliary stent and liver metastasis were independent factors affecting survival.ConclusionThe implementation of SEMS combined with I-125 seeds resulted in significantly longer stent patency and survival times than that of SEMS implantation alone, which is thus worthy of clinical promotion and application.
引用
收藏
页码:7729 / 7737
页数:9
相关论文
共 30 条
  • [1] Feasibility and safety of percutaneous transhepatic endobiliary radiofrequency ablation as an adjunct to biliary stenting in malignant biliary obstruction
    Acu, B.
    Ozturk, E. Kurtulus
    [J]. DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2018, 99 (04) : 237 - 245
  • [2] Plastic vs. Self-Expandable Metal Stents for Palliation in Malignant Biliary Obstruction: A Series of Meta-Analyses
    Almadi, Majid A.
    Barkun, Alan
    Martel, Myriam
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2017, 112 (02) : 260 - 273
  • [3] Self-expandable metallic stent with 125I seed strand in malignant biliary obstruction: a self-made delivery system and novel implantation method
    An, Rui
    Zhang, Hu
    Yu, Jing
    Cao, Yunbao
    Ren, Jialiang
    Guo, Wangang
    Luo, Zhonghua
    [J]. ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (24)
  • [4] Malignant biliary obstruction: From palliation to treatment
    Boulay, Brian R.
    Birg, Aleksandr
    [J]. WORLD JOURNAL OF GASTROINTESTINAL ONCOLOGY, 2016, 8 (06) : 498 - 508
  • [5] One-channel double stent implantation for hilar biliary obstructions
    Cao, Guangshao
    Cao, Huicun
    Liu, Jian
    Wang, Yudan
    Wang, Zhenyu
    [J]. EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2013, 5 (04) : 1179 - 1183
  • [6] Endoscopic biliary stenting: indications, choice of stents, and results: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline - Updated October 2017
    Dumonceau, Jean-Marc
    Tringali, Andrea
    Papanikolaou, Ioannis S.
    Blero, Daniel
    Mangiavillano, Benedetto
    Schmidt, Arthur
    Vanbiervliet, Geoffroy
    Costamagna, Guido
    Deviere, Jacques
    Garcia-Cano, Jesus
    Gyoekeres, Tibor
    Hassan, Cesare
    Prat, Frederic
    Siersema, Peter D.
    van Hooft, Jeanin E.
    [J]. ENDOSCOPY, 2018, 50 (09) : 910 - 930
  • [7] Comparative Study of Percutaneous Transhepatic Biliary Stent Placement with or without Iodine-125 Seeds for Treating Patients with Malignant Biliary Obstruction
    Hasimu, Asihaer
    Gu, Jun-Peng
    Ji, Wei-Zheng
    Zhang, Hai-Xiao
    Zhu, Di-Wen
    Ren, Wei-Xin
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2017, 28 (04) : 583 - 593
  • [8] Effectiveness and safety of CT-guided 125I seed brachytherapy for postoperative locoregional recurrence in patients with non small cell lung cancer
    Huo, Xiaodong
    Wang, Huixing
    Yang, Jingkui
    Li, Xiaodong
    Yan, Weiliang
    Huo, Bin
    Zheng, Guangjun
    Chai, Shude
    Wang, Junjie
    Guan, Zhiyu
    Yu, Zhengtao
    [J]. BRACHYTHERAPY, 2016, 15 (03) : 370 - 380
  • [9] Percutaneous self-expandable uncovered metallic stents in malignant biliary obstruction -: Complications, follow-up and reintervention in 154 patients
    Inal, M
    Akgül, E
    Aksungur, E
    Demiryürek, H
    Yagmur, Ö
    [J]. ACTA RADIOLOGICA, 2003, 44 (02) : 139 - 146
  • [10] Clinical benefit of radiation therapy and metallic stenting for unresectable hilar cholangiocarcinoma
    Isayama, Hiroyuki
    Tsujino, Takeshi
    Nakai, Yousuke
    Sasaki, Takashi
    Nakagawa, Keiichi
    Yamashita, Hideomi
    Aoki, Taku
    Koike, Kazuhiko
    [J]. WORLD JOURNAL OF GASTROENTEROLOGY, 2012, 18 (19) : 2364 - 2370