Uncertainties in the dosimetric heterogeneity correction and its potential effect on local control in lung SBRT

被引:4
作者
Erickson, Brett G. [1 ]
Cui, Yunfeng [1 ]
Ackerson, Bradley G. [1 ]
Kelsey, Christopher R. [1 ]
Yin, Fang-Fang [1 ]
Niedzwiecki, Donna [2 ]
Adamson, Justus [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC 27708 USA
[2] Duke Univ, Med Ctr, Dept Biostat & Bioinformat, Durham, NC USA
关键词
lung SBRT; local control; dose calculation; dosimetric accuracy; DOSE CALCULATION ALGORITHMS; CLINICAL-OUTCOMES; RADIATION-THERAPY; SMALL FIELDS; DISTRIBUTIONS; ACCURACY; CANCER; TUMORS; MEDIA; MODEL;
D O I
10.1088/2057-1976/acbeae
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective. Dose calculation in lung stereotactic body radiation therapy (SBRT) is challenging due to the low density of the lungs and small volumes. Here we assess uncertainties associated with tissue heterogeneities using different dose calculation algorithms and quantify potential associations with local failure for lung SBRT. Approach. 164 lung SBRT plans were used. The original plans were prepared using Pencil Beam Convolution (PBC, n = 8) or Anisotropic Analytical Algorithm (AAA, n = 156). Each plan was recalculated with AcurosXB (AXB) leaving all plan parameters unchanged. A subset (n = 89) was calculated with Monte Carlo to verify accuracy. Differences were calculated for the planning target volume (PTV) and internal target volume (ITV) Dmean[Gy], D99%[Gy], D95%[Gy], D1%[Gy], and V100%[%]. Dose metrics were converted to biologically effective doses (BED) using alpha/beta = 10Gy. Regression analysis was performed for AAA plans investigating the effects of various parameters on the extent of the dosimetric differences. Associations between the magnitude of the differences for all plans and outcome were investigated using sub-distribution hazards analysis. Main results. For AAA cases, higher energies increased the magnitude of the difference (Delta Dmean of -3.6%, -5.9%, and -9.1% for 6X, 10X, and 15X, respectively), as did lung volume (Delta D99% of -1.6% per 500cc). Regarding outcome, significant hazard ratios (HR) were observed for the change in the PTV and ITV D1% BEDs upon univariate analysis (p = 0.042, 0.023, respectively). When adjusting for PTV volume and prescription, the HRs for the change in the ITV D1% BED remained significant (p = 0.039, 0.037, respectively). Significance. Large differences in dosimetric indices for lung SBRT can occur when transitioning to advanced algorithms. The majority of the differences were not associated with local failure, although differences in PTV and ITV D1% BEDs were associated upon univariate analysis. This shows uncertainty in near maximal tumor dose to potentially be predictive of treatment outcome.
引用
收藏
页数:12
相关论文
共 32 条
[31]   A comprehensive dosimetric study on switching from a Type-B to a Type-C dose algorithm for modern lung SBRT [J].
Zhou, Christina ;
Bennion, Nathan ;
Ma, Rongtao ;
Liang, Xiaoying ;
Wang, Shuo ;
Zvolanek, Kristina ;
Hyun, Megan ;
Li, Xiaobo ;
Zhou, Sumin ;
Zhen, Weining ;
Lin, Chi ;
Wahl, Andrew ;
Zheng, Dandan .
RADIATION ONCOLOGY, 2017, 12
[32]   Dosimetric differences between local failure and local controlled non-small cell lung cancer patients treated with stereotactic body radiotherapy: A matched-pair study [J].
Zhuang, Tingliang ;
Woody, Neil M. ;
Liu, Han ;
Cherian, Sheen ;
Reddy, Chandana A. ;
Qi, Peng ;
Magnelli, Anthony ;
Djemil, Toufik ;
Stephans, Kevin L. ;
Xia, Ping ;
Videtic, Gregory M. M. .
JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2018, 62 (03) :420-424