Non-enzymatic glucose sensing using a nickel hydroxide/chitosan modified screen-printed electrode incorporated into a flow injection analysis system

被引:3
作者
McCormick, Wesley J. [1 ]
Mcloughlin, Eva [1 ]
Mccrudden, Denis [1 ]
机构
[1] Atlantic Technol Univ, Dept Life & Phys Sci, Letterkenny F92 FC93, Donegal, Ireland
关键词
SENSORS; NANOCOMPOSITE; FOAM; FILM;
D O I
10.1039/d3ay01145c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This works presents a novel screen-printed carbon electrode modified with nickel hydroxide nanoparticles and chitosan (Ni(OH)2/CS/SPCE) for the non-enzymatic flow injection amperometric detection of glucose. The electrode was modified by drop-casting a suspension of the synthesised nanocomposite onto the screen-printed electrode and dried for 1 hour at room temperature. EDX analysis was used to investigate the chemical composition of the electrode before and after modifying. The electrochemical response of the unmodified SPCE and modified electrode was initially investigated by cyclic voltammetry (CV) using 0.1 M NaOH as the supporting electrolyte. CVs showed catalytic activity for glucose oxidation using the Ni(OH)2/CS/SPCE at 0.55 V. During flow injection analysis (FIA), 0.60 V and 1.5 mL min-1 were identified as the optimal potential and flow rate, respectively. A wide linear range of detection was observed (0.2 to 10.0 mM) with a sensitivity and limit of detection of 913 mu A mM-1 cm-2 and 0.0174 mM, respectively. The modified electrode also displayed excellent repeatability (RSD = 0.47%, n = 20) and good reproducibility (RSD = 2.52%, n = 6). The modified electrode was shown to be very selectivity for glucose over other interferences commonly found in human blood samples. The practicality of the developed flow injection-amperometric system (FIA-Amp) was validated by the quantification of glucose in real serum samples, where results were in close agreement with those obtained from the local hospital. This works presents a novel screen-printed carbon electrode modified with nickel hydroxide nanoparticles and chitosan (Ni(OH)2/CS/SPCE) for the non-enzymatic flow injection amperometric detection of glucose.
引用
收藏
页码:5071 / 5077
页数:7
相关论文
共 44 条
  • [1] Recent development in chitosan-based electrochemical sensors and its sensing application
    Annu
    Raja, Antony Nitin
    [J]. INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2020, 164 : 4231 - 4244
  • [2] Flow-Injection Amperometric Determination of Glucose Using Nickel Oxide-Cobalt (II,III) Oxide and Nickel Oxide-Copper Nanoparticle Modified Pencil Graphite Electrodes
    Ayaz, Selen
    Karakaya, Serkan
    Emir, Gamze
    Usakligil, Nihan
    Dilgin, Didem Giray
    Dilgin, Yusuf
    [J]. ANALYTICAL LETTERS, 2022, 55 (13) : 2046 - 2057
  • [3] Flow injection amperometric determination of hydrazine at a cupric-neocuproine complex/anionic surfactant modified disposable electrode
    Ayaz, Selen
    Dilgin, Yusuf
    Apak, Resat
    [J]. MICROCHEMICAL JOURNAL, 2020, 159
  • [4] A novel enzyme-free FI-amperometric glucose biosensor at Cu nanoparticles modified graphite pencil electrode
    Ayaz, Selen
    Karakaya, Serkan
    Emir, Gamze
    Dilgin, Didem Giray
    Dilgin, Yusuf
    [J]. MICROCHEMICAL JOURNAL, 2020, 154
  • [5] A simple and flexible enzymatic glucose biosensor using chitosan entrapped mesoporous carbon nanocomposite
    Barathi, Palani
    Thirumalraj, Balamurugan
    Chen, Shen-Ming
    Angaiah, Subramania
    [J]. MICROCHEMICAL JOURNAL, 2019, 147 : 848 - 856
  • [6] Glycemic Control for Type 2 Diabetes Mellitus Patients: A Systematic Review
    Bin Rakhis, Saud A., Sr.
    AlDuwayhis, Nawaf Mohammed
    Aleid, Naif
    AlBarrak, Abdullah Nasser
    Aloraini, Abdullah Ahmed
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (06)
  • [7] The electrochemical glucose sensing based on the chitosan-carbon nanotube hybrid
    Choi, Young-Bong
    Kim, Han-Sem
    Jeon, Won-Yong
    Lee, Bo-Hee
    Shin, Ueon Sang
    Kim, Hyug-Han
    [J]. BIOCHEMICAL ENGINEERING JOURNAL, 2019, 144 : 227 - 234
  • [8] An electrochemical sensor based on chitosan capped with gold nanoparticles combined with a voltammetric electronic tongue for quantitative aspirin detection in human physiological fluids and tablets
    Diouf, Alassane
    Moufid, Mohammed
    Bouyahya, Driss
    Osterlund, Lars
    El Bari, Nezha
    Bouchikhi, Benachir
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2020, 110
  • [9] Metal oxide based non-enzymatic electrochemical sensors for glucose detection
    Dong, Qiuchen
    Ryu, Heejeong
    Lei, Yu
    [J]. ELECTROCHIMICA ACTA, 2021, 370
  • [10] A simple method to fabricate a chitosan-gold nanoparticles film and its application in glucose biosensor
    Du, Ying
    Luo, Xi-Liang
    Xu, Jing-Juan
    Chen, Hong-Yuan
    [J]. BIOELECTROCHEMISTRY, 2007, 70 (02) : 342 - 347