Prospective validation of a risk score to predict pacemaker implantation after transcatheter aortic valve replacement

被引:0
作者
Black, George B. [1 ]
Kim, Joshua H. [2 ]
Vitter, Sophie [2 ]
Ibrahim, Rand [1 ]
Lisko, John C. [1 ]
Perdoncin, Emily [1 ]
Shekiladze, Nikoloz [1 ]
Gleason, Patrick T. [1 ]
Grubb, Kendra J. [3 ]
Greenbaum, Adam B. [1 ]
Devireddy, Chandan M. [1 ]
Guyton, Robert A. [3 ]
Leshnower, Bradley [3 ]
Merchant, Faisal M. [1 ]
El-Chami, Mikhael [1 ]
Westerman, Stacy B. [1 ]
Shah, Anand D. [1 ]
Leon, Angel R. [1 ]
Lloyd, Michael S. [1 ]
Babaliaros, Vasilis C. [1 ]
Kiani, Soroosh [4 ,5 ]
机构
[1] Emory Univ, Sch Med, Dept Med, Div Cardiol, Atlanta, GA USA
[2] Emory Univ, Sch Med, Dept Med, Atlanta, GA USA
[3] Emory Univ, Sch Med, Dept Surg, Div Cardiothorac Surg, Atlanta, GA 30308 USA
[4] UMass Chan Med Sch, Dept Med, Div Rheumatol, Worcester, MA USA
[5] UMass Chan Med Sch, Dept Cardiol, Div Cardiovasc Dis, Sect Electrophysiol, 55 Lake Ave North, Worcester, MA 01655 USA
关键词
heart block; pacemaker; TAVR; CONDUCTION DISTURBANCES; ATRIAL-FIBRILLATION; SAPIEN XT; OUTCOMES; STRATIFICATION; PERFORMANCE; MORTALITY; EUROSCORE; STENOSIS; SOCIETY;
D O I
10.1111/jce.16061
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction The need for pacemaker is a common complication after transcatheter aortic valve replacement (TAVR). We previously described the Emory Risk Score (ERS) to predict the need for new pacemaker implant (PPM) after TAVR. Metrics included in the score are a history of syncope, pre-existing RBBB, QRS duration= 140 ms, and prosthesis oversizing= 16%. To prospectively validate the previously described risk score.Methods We prospectively evaluated all patients without pre-existing pacemakers, ICD, or pre-existing indications for pacing undergoing TAVR with the Edwards SAPIEN 3 prosthesis at our institution from March 2019 to December 2020 (n = 661). Patients were scored prospectively; however, results were blinded from clinical decision-making. The primary endpoint was PPM at 30 days after TAVR. Performance of the ERS was evaluated using logistic regression, a calibration curve to prior performance, and receiver operating characteristic (ROC) analysis.Results A total of 48 patients (7.3%) had PPM after TAVR. A higher ERS predicted an increased likelihood of PPM (OR 2.61, 95% CI: 2.05-3.25 per point, p < 0.001). There was good correlation between observed and expected values on the calibration curve (slope = 1.04, calibration at large = 0.001). The area under the ROC curve was 0.81 (95% CI [0.74-0.88], p < 0.001).Conclusions The ERS prospectively predicted the need for PPM in a serial, real-world cohort of patients undergoing TAVR with a balloon-expandable prosthesis, confirming findings previously described in retrospective cohorts. Notably, the prospective performance of the score was comparable with that of the initial cohorts. The risk score could serve as a framework for preprocedural risk stratification for PPM after TAVR.
引用
收藏
页码:2225 / 2232
页数:8
相关论文
共 32 条
[1]  
Altman DG, 2000, STAT MED, V19, P453, DOI 10.1002/(SICI)1097-0258(20000229)19:4<453::AID-SIM350>3.3.CO
[2]  
2-X
[3]   Reducing Ventricular Pacing Frequency in Patients With Atrioventricular Block: Is It Time to Change the Current Pacing Paradigm? [J].
Auricchio, Angelo ;
Ellenbogen, Kenneth A. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2016, 9 (09)
[4]   Comparison of Transfemoral Transcatheter Aortic Valve Replacement Performed in the Catheterization Laboratory (Minimalist Approach) Versus Hybrid Operating Room (Standard Approach) Outcomes and Cost Analysis [J].
Babaliaros, Vasilis ;
Devireddy, Chandan ;
Lerakis, Stamatios ;
Leonardi, Robert ;
Iturra, Sebastian A. ;
Mavromatis, Kreton ;
Leshnower, Bradley G. ;
Guyton, Robert A. ;
Kanitkar, Mihir ;
Keegan, Patricia ;
Simone, Amy ;
Stewart, James P. ;
Ghasemzadeh, Nima ;
Block, Peter ;
Thourani, Vinod H. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (08) :898-904
[5]   Procedural Results and Clinical Outcomes of Transcatheter Aortic Valve Implantation in Switzerland An Observational Cohort Study of Sapien 3 Versus Sapien XT Transcatheter Heart Valves [J].
Binder, Ronald K. ;
Stortecky, Stefan ;
Heg, Dik ;
Tueller, David ;
Jeger, Raban ;
Toggweiler, Stefan ;
Pedrazzini, Giovanni ;
Amann, Franz W. ;
Ferrari, Enrico ;
Noble, Stephane ;
Nietlispach, Fabian ;
Maisano, Francesco ;
Raber, Lorenz ;
Roffi, Marco ;
Grunenfelder, Jurg ;
Juni, Peter ;
Huber, Christoph ;
Windecker, Stephan ;
Wenaweser, Peter .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (10)
[6]   Impact of Post-Implant SAPIEN XT Geometry and Position on Conduction Disturbances, Hemodynamic Performance, and Paravalvular Regurgitation [J].
Binder, Ronald K. ;
Webb, John G. ;
Toggweiler, Stefan ;
Freeman, Melanie ;
Barbanti, Marco ;
Willson, Alexander B. ;
Alhassan, Donya ;
Hague, Cameron J. ;
Wood, David A. ;
Leipsic, Jonathon .
JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (05) :462-468
[7]   Computed Tomography-Based Oversizing Degrees and Incidence of Paravalvular Regurgitation of a New Generation Transcatheter Heart Valve [J].
Blanke, Philipp ;
Pibarot, Philippe ;
Hahn, Rebecca ;
Weissman, Neil ;
Kodali, Susheel ;
Thourani, Vinod ;
Parvataneni, Rupa ;
Dvir, Danny ;
Naoum, Christopher ;
Norgaard, Bjarne L. ;
Douglas, Pamela ;
Jaber, Wael ;
Khalique, Omar K. ;
Jilaihawi, Hasan ;
Mack, Michael ;
Smith, Craig ;
Leon, Martin ;
Webb, John ;
Leipsic, Jonathon .
JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (08) :810-820
[8]   CHADS2 versus CHA2DS2-VASc score in assessing the stroke and thromboembolism risk stratification in patients with atrial fibrillation: a systematic review and meta-analysis [J].
Chen, Jia-Yuan ;
Zhang, Ai-Dong ;
Lu, Hong-Yan ;
Guo, Jun ;
Wang, Fei-Fei ;
Li, Zi-Cheng .
JOURNAL OF GERIATRIC CARDIOLOGY, 2013, 10 (03) :258-266
[9]   Anatomical risk models for paravalvular leak and landing zone complications for balloon-expandable transcatheter aortic valve replacement [J].
Condado, Jose F. ;
Corrigan, Frank E., III ;
Lerakis, Stamatios ;
Parastatidis, Ioannis ;
Stillman, Arthur E. ;
Binongo, Jose N. ;
Stewart, James ;
Mavromatis, Kreton ;
Devireddy, Chandan ;
Leshnower, Bradley ;
Guyton, Robert ;
Forcillo, Jessica ;
Patel, Ateet ;
Thourani, Vinod H. ;
Block, Peter C. ;
Babaliaros, Vasilis .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (04) :690-700
[10]   Changes in the Pacemaker Rate After Transition From Edwards SAPIEN XT to SAPIEN 3 Transcatheter Aortic Valve Implantation The Critical Role of Valve Implantation Height [J].
De Torres-Alba, Fernando ;
Kaleschke, Gerrit ;
Diller, Gerhard Paul ;
Vormbrock, Julia ;
Orwat, Stefan ;
Radke, Robert ;
Reinke, Florian ;
Fischer, Dieter ;
Reinecke, Holger ;
Baumgartner, Helmut .
JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (08) :805-813