Novel methods of continuous glucose monitoring and telehealth in the improvement of diabetes care: a narrative review

被引:3
作者
Hohendorff, Jerzy [1 ]
Czupryniak, Leszek [2 ]
Dzida, Grzegorz [3 ]
Fichna, Piotr [4 ]
Jarosz-Chobot, Przemyslawa [5 ]
Klupa, Tomasz [1 ]
Mysliwiec, Malgorzata [6 ]
Szadkowska, Agnieszka [7 ]
Zozulinska-Ziolkiewicz, Dorota A. [8 ]
Malecki, Maciej T. [1 ]
机构
[1] Jagiellonian Univ, Dept Metab Dis, Med Coll, Krakow, Poland
[2] Med Univ Warsaw, Dept Diabetol & Internal Med, Warsaw, Poland
[3] Med Univ Lublin, Dept Internal Dis, Lublin, Poland
[4] Poznan Univ Med Sci, Dept Pediat Diabet & Obes, Poznan, Poland
[5] Med Univ Silesia, Sch Med, Dept Childrens Diabetol, Katowice, Poland
[6] Med Univ Gdansk, Dept Pediat Diabetol & Endocrinol, Gdansk, Poland
[7] Med Univ Lodz, Dept Pediat Diabetol Endocrinol & Nephrol, Lodz, Poland
[8] Poznan Univ Med Sci, Dept Internal Med & Diabetol, Poznan, Poland
关键词
diabetes mellitus; telehealth; continuous glucose monitoring; QUALITY-OF-LIFE; BLOOD-GLUCOSE; GLYCEMIC CONTROL; SENSING TECHNOLOGY; COST-EFFECTIVENESS; ADULTS; FREQUENCY; RECOMMENDATIONS; ASSOCIATION; MULTICENTER;
D O I
10.5114/aoms/139025
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Standard markers of glycaemic control, such as glycated haemoglobin (HbA1c) and self-measurement of blood glucose (SMBG), have proven insuf-ficient. HbA1c is an averaged measurement that does not give information about glucose variability. SMBG provides limited, intermittent blood glu-cose (BG) values over the day and is associated with poor compliance be-cause of the invasiveness of the method and social discomfort. In contrast to glucometers, continuous glucose monitoring (CGM) devices do not re-quire finger-stick blood samples, but instead measure BG via percutaneous or subcutaneous sensors. The immediate benefits of CGM include preven-tion of hypoglycaemia or hyperglycaemia, and automated analysis of long-term glycaemic data enables reliable treatment adjustments. This review describes the principles of CGM and how CGM data have changed diabetes treatment standards by introducing new glycaemic control parameters. It also compares different CGM devices and examines how the convenience of sharing CGM data in telehealth applies to the current coronavirus-19 pandemic.
引用
收藏
页码:757 / 764
页数:8
相关论文
共 49 条
[1]   How Can We Realize the Clinical Benefits of Continuous Glucose Monitoring? [J].
Ajjan, Ramzi A. .
DIABETES TECHNOLOGY & THERAPEUTICS, 2017, 19 :S27-S36
[2]   Glycemic Targets: Standards of Medical Care in Diabetes-2020 [J].
不详 .
DIABETES CARE, 2020, 43 :S66-S76
[3]  
[Anonymous], 2016, DIABETES CARE, V39, pS1, DOI [10.2337/dc16-s003, 10.2337/dc19-sdis01, 10.2337/dc20-Sint, 10.2337/dc16-S001, 10.2337/dc19-Sint01, 10.2337/dc20-SINT, 10.2337/dc19-SINT01]
[4]  
[Anonymous], 2014, Designation D7012-13: Standard Test Method for Compressive strength and elastic moduli of intact rock core specimens under varying states of stress and temperatures, P1
[5]   Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range [J].
Battelino, Tadej ;
Danne, Thomas ;
Bergenstal, Richard M. ;
Amiel, Stephanie A. ;
Beck, Roy ;
Biester, Torben ;
Bosi, Emanuele ;
Buckingham, Bruce A. ;
Cefalu, William T. ;
Close, Kelly L. ;
Cobelli, Claudio ;
Dassau, Eyal ;
DeVries, J. Hans ;
Donaghue, Kim C. ;
Dovc, Klemen ;
Doyle, Francis J. ;
Garg, Satish ;
Grunberger, George ;
Heller, Simon ;
Heinemann, Lutz ;
Hirsch, Irl B. ;
Hovorka, Roman ;
Jia, Weiping ;
Kordonouri, Olga ;
Kovatchev, Boris ;
Kowalski, Aaron ;
Laffel, Lori ;
Levine, Brian ;
Mayorov, Alexander ;
Mathieu, Chantal ;
Murphy, Helen R. ;
Nimri, Revital ;
Norgaard, Kirsten ;
Parkin, Christopher G. ;
Renard, Eric ;
Rodbard, David ;
Saboo, Banshi ;
Schatz, Desmond ;
Stoner, Keaton ;
Urakami, Tatsuiko ;
Weinzimer, Stuart A. ;
Phillip, Moshe .
DIABETES CARE, 2019, 42 (08) :1593-1603
[6]   Advances in technology for management of type 1 diabetes [J].
Beck, Roy W. ;
Bergenstal, Richard M. ;
Laffel, Lori M. ;
Pickup, John C. .
LANCET, 2019, 394 (10205) :1265-1273
[7]   Effect of Continuous Glucose Monitoring on Glycemic Control in Adults With Type 1 Diabetes Using Insulin Injections The DIAMOND Randomized Clinical Trial [J].
Beck, Roy W. ;
Riddlesworth, Tonya ;
Ruedy, Katrina ;
Ahmann, Andrew ;
Bergenstal, Richard ;
Haller, Stacie ;
Kollman, Craig ;
Kruger, Davida ;
McGill, Janet B. ;
Polonsky, William ;
Toschi, Elena ;
Wolpert, Howard ;
Price, David .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2017, 317 (04) :371-378
[8]   Threshold-Based Insulin-Pump Interruption for Reduction of Hypoglycemia [J].
Bergenstal, Richard M. ;
Klonoff, David C. ;
Garg, Satish K. ;
Bode, Bruce W. ;
Meredith, Melissa ;
Slover, Robert H. ;
Ahmann, Andrew J. ;
Welsh, John B. ;
Lee, Scott W. ;
Kaufman, Francine R. .
NEW ENGLAND JOURNAL OF MEDICINE, 2013, 369 (03) :224-232
[9]   Recommendations for Standardizing Glucose Reporting and Analysis to Optimize Clinical Decision Making in Diabetes: The Ambulatory Glucose Profile (AGP) [J].
Bergenstal, Richard M. ;
Ahmann, Andrew J. ;
Bailey, Timothy ;
Beck, Roy W. ;
Bissen, Joan ;
Buckingham, Bruce ;
Deeb, Larry ;
Dolin, Robert H. ;
Garg, Satish K. ;
Goland, Robin ;
Hirsch, Irl B. ;
Klonoff, David C. ;
Kruger, Davida F. ;
Matfin, Glenn ;
Mazze, Roger S. ;
Olson, Beth A. ;
Parkin, Christopher ;
Peters, Anne ;
Powers, Margaret A. ;
Rodriguez, Henry ;
Southerland, Phil ;
Strock, Ellie S. ;
Tamborlane, William ;
Wesley, David M. .
DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 (03) :198-211
[10]   Novel glucose-sensing technology and hypoglycaemia in type 1 diabetes: a multicentre, non-masked, randomised controlled trial [J].
Bolinder, Jan ;
Antuna, Ramiro ;
Geelhoed-Duijvestijn, Petronella ;
Kroeger, Jens ;
Weitgasser, Raimund .
LANCET, 2016, 388 (10057) :2254-2263