Follow-up studies of the classical landmark studies in Glaucoma

被引:1
作者
Meier-Gibbons, Frances [1 ]
Toteberg-Harms, Marc [2 ]
机构
[1] Eye Ctr Rapperswil, St Gallen, Switzerland
[2] Augusta Univ, Med Coll Georgia, Dept Ophthalmol, Augusta, GA USA
关键词
glaucoma; landmark study; landmark trial; randomized controlled trial; OCULAR HYPERTENSION TREATMENT; BASE-LINE CHARACTERISTICS; LASER TRABECULOPLASTY; A-MULTICENTER; PRIMARY TUBE; DESIGN; TRIAL; TRABECULECTOMY; OUTCOMES; AGIS;
D O I
10.1097/ICU.0000000000000926
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose of reviewIt was not until the nineteen nineties that there was scientific evidence for the primary treatment concept of glaucoma, lowering intraocular pressure. The treatment concept of lowering intraocular pressure is now proven by randomized controlled clinical trials (landmark studies). This review provides an overview of the follow-up studies to these landmark studies from the last 18 months.Recent findingsThe 20-year data of the ocular hypertension treatment study showed a 49% incidence of primary open-angle glaucoma. The data of this landmark study was used for developing different machine learning algorithms. Bilateral disease, disc hemorrhages, and higher intraocular pressure (IOP) were risk factors for visual field deterioration in the United Kingdom Glaucoma Treatment Study. The Advanced Glaucoma Intervention Trial and the Collaborative Initial Glaucoma Treatment Study identified demographic factors, comorbidity, and clinical variables associated with visual field damage. Analysis was performed on Chinese subsets from the Laser in Glaucoma and Ocular Hypertension Study (LiGHT). Looking at all the follow-up studies to the tube shunt landmark studies, preoperative IOP, neovascular glaucoma, Ahmed implantation, and younger age were predictors of failure. A follow-up study to the Effectiveness in Angle-Closure Glaucoma in Lens Extraction Study showed that patients were ten times more likely to maintain a drop-free target IOP after lens extraction than after laser iridotomy. A superior location for iridotomy results in significantly more significant angle widening than temporal or nasal locations, as shown by a follow-up study to the Zhongshan Angle Closure Prevention Trial using OCT and gonioscopy.The number of published follow-up studies to the landmark studies in glaucoma show the ongoing development of clinical questions in management of glaucoma.
引用
收藏
页码:116 / 122
页数:7
相关论文
共 50 条
[21]   Optimal selection of individuals for repeated covariate measurements in follow-up studies [J].
Reinikainen, Jaakko ;
Karvanen, Juha ;
Tolonen, Hanna .
STATISTICAL METHODS IN MEDICAL RESEARCH, 2016, 25 (06) :2420-2433
[22]   The Relationship Between the Mean Deviation Slope and Follow-up Intraocular Pressure in Open-angle Glaucoma Patients [J].
Fukuchi, Takeo ;
Yoshino, Takaiko ;
Sawada, Hideko ;
Seki, Masaaki ;
Togano, Tetsuya ;
Tanaka, Takayuki ;
Ueda, Jun ;
Abe, Haruki .
JOURNAL OF GLAUCOMA, 2013, 22 (09) :689-697
[23]   The potential of annexin-labelling for the diagnosis and follow-up of glaucoma [J].
Normando, Eduardo M. ;
Turner, Lisa A. ;
Cordeiro, M. Francesca .
CELL AND TISSUE RESEARCH, 2013, 353 (02) :279-285
[24]   Construction of an Ophthalmological Calendar for the Therapeutic Follow-Up of Glaucoma in the Elderly [J].
de Abreu, Margarida da Silva Neves ;
Galdino, Maria Clara Palitot ;
Matos, Suellen Duarte de Oliveira ;
Cavalcanti, Carla Christina de Lima Pereira Bezerra ;
Trigueiro, Debora Raquel Soares Guedes .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2023, 20 (02)
[25]   THE FOLLOW-UP OF PATIENTS SCREENED FOR GLAUCOMA WITH NONMYDRIATIC FUNDUS PHOTOGRAPHY [J].
KOMULAINEN, R ;
TUULONEN, A ;
AIRAKSINEN, PJ .
INTERNATIONAL OPHTHALMOLOGY, 1992, 16 (06) :465-469
[26]   The potential of annexin-labelling for the diagnosis and follow-up of glaucoma [J].
Eduardo M. Normando ;
Lisa A. Turner ;
M. Francesca Cordeiro .
Cell and Tissue Research, 2013, 353 :279-285
[27]   Baerveldt Glaucoma Implant in the Ciliary Sulcus Midterm Follow-up [J].
Prata, Tiago Santos ;
Mehta, Anish ;
De Moraes, Carlas Gustavo V. ;
Tello, Celso ;
Liebmann, Jeffrey ;
Ritch, Robert .
JOURNAL OF GLAUCOMA, 2010, 19 (01) :15-18
[28]   The PAUL Glaucoma Implant in the management of uveitic glaucoma-3-year follow-up [J].
Richardson, Jay ;
Tacea, Filofteia ;
Yu, Jonathan ;
Yau, Kenneth ;
Fenerty, Cecilia ;
Au, Leon .
EYE, 2024, :931-937
[29]   Knowledge about glaucoma and barriers to follow-up care in a community glaucoma screening program [J].
Altangerel, Undraa ;
Nallamshetty, Hema S. ;
Uhler, Tara ;
Fontanarosa, Joann ;
Steinmann, William C. ;
Almodin, Juliana M. ;
Chen, Brian H. ;
Henderer, Jeffrey D. .
CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2009, 44 (01) :66-69
[30]   Canaloplasty in Open-Angle Glaucoma Surgery: A Four-Year Follow-Up [J].
Brusini, Paolo .
SCIENTIFIC WORLD JOURNAL, 2014,