Prospective evaluation of liver shearwave elastography measurements with 3 different technologies and same day liver biopsy in patients with chronic liver disease

被引:8
作者
Atzori, Sebastiana M. [1 ,2 ,6 ]
Pasha, Yasmin [1 ]
Maurice, James B. [1 ,3 ]
Taylor-Robinson, Simon D. [1 ]
Campbell, Louise [1 ,4 ]
Lim, Adrian K. P. [5 ]
机构
[1] Imperial Coll London, Dept Surg & Canc, St Mary Hosp, Liver Unit, QEQM Wing,St Marys Campus, London W2 1NY, England
[2] Sassari Univ Hosp, Dept Med, Via Enrico de Nicola, I-07100 Sassari, Italy
[3] UCL Inst Liver & Digest Hlth, Royal Free Hosp Campus,Rowland Hill St, London NW3 2QG, England
[4] Tawazun Hlth, Off Clin Director, London W1G 9QN, England
[5] Imperial Coll Healthcare NHS Trust, Charing Cross Hosp, Imaging Dept, Fulham Palace Rd, London W6 8RF, England
[6] Univ Hosp, Dept Med, Via Enrico de Nicola, I-07100 Sassari, Italy
基金
英国惠康基金;
关键词
Fibroscan; Liver biopsy; Liver fibrosis; Liver stiffness measurements; Shear wave elastography; RADIATION FORCE IMPULSE; CHRONIC HEPATITIS-C; TRANSIENT ELASTOGRAPHY; STIFFNESS MEASUREMENT; WAVE ELASTOGRAPHY; ARFI ELASTOGRAPHY; FIBROSIS SOCIETY; XL PROBES; CONSENSUS; REPRODUCIBILITY;
D O I
10.1016/j.dld.2023.10.020
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Most ultrasound-based methods for assessing liver fibrosis still need further validation with liver biopsy used as gold standard to assess their accuracy. Aims: To assess accuracy of three shear wave elastography (SWE) methods: 1) Philips Elast Point Quantification (ElastPQ (TM) ), 2) Siemens Virtual Touch (TM) Quantification (VTQ) acoustic radiation force impulse (ARFI), and 3) transient elastography (TE) measured by Echosens Fibroscan (TM) . Methods: 160 patients underwent liver stiffness measurements (LSM) with three SWE methods immediately prior to liver biopsy. Results: The number of LSM required for reliable studies could be reduced to 6 for ElastPQ and to 7 for VTQ from standard recommendations of 10. Significant fibrosis and interquartile range/median (IQR/M) > 30 were independent predictors for lower reliability for detection of liver fibrosis. Ordinal logistic regression corrected for age showed that there was a significant interaction between steatosis ( p = 0.008) and lobular inflammation ( p = 0.04) and VTQ (ARFI) and between lobular inflammation and TE ( p = 0.006). Conclusions: We showed variations in SWE measurements using different ARFI technologies. TE and ElastPQ achieved good diagnostic performance, whereas VTQ showed lower diagnostic accuracy. The number of measurements required for reliable studies can be reduced to 6 for ElastPQ and to 7 for VTQ, which have important clinical implications. (c) 2023 The Author(s). Published by Elsevier Ltd on behalf of Editrice Gastroenterologica Italiana S.r.l. This is an open access article under the CC BY license ( http://creativecommons.org/licenses/by/4.0/ )
引用
收藏
页码:484 / 494
页数:11
相关论文
共 53 条
[1]   Evaluation of liver fibrosis: A concise review [J].
Afdhal, NH ;
Nunes, D .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2004, 99 (06) :1160-1174
[2]   Reliability of transient elastography for the diagnosis of advanced fibrosis in chronic hepatitis C [J].
Arena, U. ;
Vizzutti, F. ;
Abraldes, J. G. ;
Corti, G. ;
Stasi, C. ;
Moscarella, S. ;
Milani, S. ;
Lorefice, E. ;
Petrarca, A. ;
Romanelli, R. G. ;
Laffi, G. ;
Bosch, J. ;
Marra, F. ;
Pinzani, M. .
GUT, 2008, 57 (09) :1288-1293
[3]   The Accuracy of Ultrasound Controlled Attenuation Parameter in Diagnosing Hepatic Fat Content [J].
Atzori, Sebastiana ;
Pasha, Yasmin ;
Maurice, James B. ;
Taylor-Robinson, Simon ;
Campbell, Louise ;
Lim, Adrian K. P. .
HEPATIC MEDICINE-EVIDENCE AND RESEARCH, 2023, 15 :51-61
[4]   Expanding the Baveno VI Criteria for the Screening of Varices in Patients With CompensatedAdvancedChronicLiverDisease [J].
Augustin, Salvador ;
Pons, Monica ;
Maurice, James B. ;
Bureau, Christophe ;
Stefanescu, Horia ;
Ney, Michel ;
Blasco, Helene ;
Procopet, Bogdan ;
Tsochatzis, Emmanuel ;
Westbrook, Rachel H. ;
Bosch, Jaime ;
Berzigotti, Annalisa ;
Abraldes, Juan G. ;
Genesca, Joan .
HEPATOLOGY, 2017, 66 (06) :1980-1988
[5]   Elastography Assessment of Liver Fibrosis: Society of Radiologists in Ultrasound Consensus Conference Statement (Reprinted) [J].
Barr, Richard G. ;
Ferraioli, Giovanna ;
Palmeri, Mark L. ;
Goodman, Zachary D. ;
Garcia-Tsao, Guadalupe ;
Rubin, Jonathan ;
Garra, Brian ;
Myers, Robert P. ;
Wilson, Stephanie R. ;
Rubens, Deborah ;
Levine, Deborah .
ULTRASOUND QUARTERLY, 2016, 32 (02) :94-107
[6]   Elastography Assessment of Liver Fibrosis: Society of Radiologists in Ultrasound Consensus Conference Statement [J].
Barr, Richard G. ;
Ferraioli, Giovanna ;
Palmeri, Mark L. ;
Goodman, Zachary D. ;
Garcia-Tsao, Guadalupe ;
Rubin, Jonathan ;
Garra, Brian ;
Myers, Robert P. ;
Wilson, Stephanie R. ;
Rubens, Deborah ;
Levine, Deborah .
RADIOLOGY, 2015, 276 (03) :845-861
[7]   Liver fibrosis [J].
Bataller, R ;
Brenner, DA .
JOURNAL OF CLINICAL INVESTIGATION, 2005, 115 (02) :209-218
[8]   An algorithm for the grading of activity in chronic hepatitis C [J].
Bedossa, P ;
Poynard, T .
HEPATOLOGY, 1996, 24 (02) :289-293
[9]   EASL Clinical Practice Guidelines on non-invasive tests for evaluation of liver disease severity and prognosis-2021 update [J].
Berzigotti, Annalisa ;
Tsochatzis, Emmanouil ;
Boursier, Jerome ;
Castera, Laurent ;
Cazzagon, Nora ;
Friedrich-Rust, Mireen ;
Petta, Salvatore ;
Thiele, Maja .
JOURNAL OF HEPATOLOGY, 2021, 75 (03) :659-689
[10]   HIV Mono-infection Is Associated With FIB-4-A Noninvasive Index of Liver Fibrosis - in Women [J].
Blackard, Jason T. ;
Welge, Jeffrey A. ;
Taylor, Lynn E. ;
Mayer, Kenneth H. ;
Klein, Robert S. ;
Celentano, David D. ;
Jamieson, Denise J. ;
Gardner, Lytt ;
Sherman, Kenneth E. .
CLINICAL INFECTIOUS DISEASES, 2011, 52 (05) :674-680