Investigating the influence of collagen cross-linking on mechanical properties of thoracic aortic tissue

被引:2
作者
Lee, Chung Won [1 ,2 ]
Lee, Chiseung [2 ,3 ]
Baek, Seungik [4 ]
Akkoyun, Emrah [5 ]
Ryu, Dongman [6 ]
机构
[1] Pusan Natl Univ, Sch Med, Dept Thorac & Cardiovasc Surg, Busan, South Korea
[2] Pusan Natl Univ Hosp, Biomed Res Inst, Busan, South Korea
[3] Pusan Natl Univ, Sch Med, Dept Convergence Med & Biomed Engn, Busan, South Korea
[4] Michigan State Univ, Dept Mech Engn, E Lansing, MI USA
[5] Turkish Acad Network & Informat Ctr, TUBITAK ULAKBIM, Ankara, Turkiye
[6] Pusan Natl Univ, Med Res Inst, Busan, South Korea
关键词
thoracic aorta; uniaxial tensile test; cross-linking; regional difference; ultimate mechanical characteristic; HUMAN ASCENDING AORTA; BIOMECHANICAL RESPONSE; CAROTID ARTERIES; STRUCTURAL BASIS; ELASTIC-MODULUS; ANEURYSM; WALL; BEHAVIOR; AGE; MICROARCHITECTURE;
D O I
10.3389/fbioe.2024.1305128
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Vascular diseases, such as abdominal aortic aneurysms, are associated with tissue degeneration of the aortic wall, resulting in variations in mechanical properties, such as tissue ultimate stress and a high slope. Variations in the mechanical properties of tissues may be associated with an increase in the number of collagen cross-links. Understanding the effect of collagen cross-linking on tissue mechanical properties can significantly aid in predicting diseased aortic tissue rupture and improve the clarity of decisions regarding surgical procedures. Therefore, this study focused on increasing the density of the aortic tissue through cross-linking and investigating the mechanical properties of the thoracic aortic tissue in relation to density. Uniaxial tensile tests were conducted on the porcine thoracic aorta in four test regions (anterior, posterior, distal, and proximal), two loading directions (circumferential and longitudinal), and density increase rates (0%-12%). As a result, the PPC (Posterior/Proximal/Circumferential) group experienced a higher ultimate stress than the PDC (Posterior/Distal/Circumferential) group. However, this relationship reversed when the specimen density exceeded 3%. In addition, the ultimate stress of the ADC (Anterior/Distal/Circumferential) and PPC group was greater than that of the APC (Anterior/Proximal/Circumferential) group, while these findings were reversed when the specimen density exceeded 6% and 9%, respectively. Finally, the high slope of the PDL (Posterior/Distal/Longitudinal) group was lower than that of the ADL (Anterior/Distal/Longitudinal) group, but the high slope of the PDL group appeared larger due to the stabilization treatment. This highlights the potential impact of density variations on the mechanical properties of specific specimen groups.
引用
收藏
页数:13
相关论文
共 47 条
[31]   Differential Tensile Strength and Collagen Composition in Ascending Aortic Aneurysms by Aortic Valve Phenotype [J].
Pichamuthu, Joseph E. ;
Phillippi, Julie A. ;
Cleary, Deborah A. ;
Chew, Douglas W. ;
Hempel, John ;
Vorp, David A. ;
Gleason, Thomas G. .
ANNALS OF THORACIC SURGERY, 2013, 96 (06) :2147-2154
[32]   Ex vivo biomechanical behavior of abdominal aortic aneurysm: Assessment using a new mathematical model [J].
Raghavan, ML ;
Webster, MW ;
Vorp, DA .
ANNALS OF BIOMEDICAL ENGINEERING, 1996, 24 (05) :573-582
[33]   THE REASON FOR THE SHAPE OF THE DISTENSIBILITY CURVES OF ARTERIES [J].
ROACH, MR ;
BURTON, AC .
CANADIAN JOURNAL OF BIOCHEMISTRY AND PHYSIOLOGY, 1957, 35 (08) :681-690
[34]   Region-dependent mechanical characterization of porcine thoracic aorta with a one-to-many correspondence method to create virtual datasets using uniaxial tensile tests [J].
Ryu D. ;
Baek S. ;
Kim J. .
Frontiers in Bioengineering and Biotechnology, 2022, 10
[35]   Multiaxial mechanical behavior of biological materials [J].
Sacks, MS ;
Sun, W .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2003, 5 :251-284
[36]   A structural basis for the aortic stress-strain relation in uniaxial tension [J].
Sokolis, Dimitrios P. ;
Kefaloyannis, Emmanuel M. ;
Kouloukoussa, Mirsini ;
Marinos, Evangelos ;
Boudoulas, Harisios ;
Karayannacos, Panayotis E. .
JOURNAL OF BIOMECHANICS, 2006, 39 (09) :1651-1662
[37]   Biomechanical response of ascending thoracic aortic aneurysms: association with structural remodelling [J].
Sokolis, Dimitrios P. ;
Kritharis, Eleftherios P. ;
Giagini, Athina T. ;
Lampropoulos, Konstantinos M. ;
Papadodima, Stavroula A. ;
Iliopoulos, Dimitrios C. .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2012, 15 (03) :231-248
[38]   Fiber micro-architecture in the longitudinal-radial and circumferential-radial planes of ascending thoracic aortic aneurysm media [J].
Tsamis, Alkiviadis ;
Phillippi, Julie A. ;
Koch, Ryan G. ;
Pasta, Salvatore ;
D'Amore, Antonio ;
Watkins, Simon C. ;
Wagner, William R. ;
Gleason, Thomas G. ;
Vorp, David A. .
JOURNAL OF BIOMECHANICS, 2013, 46 (16) :2787-2794
[39]   Molecular structure, mechanical behavior and failure mechanism of the C-terminal cross-link domain in type I collagen [J].
Uzel, Sebastien G. M. ;
Buehler, Markus J. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2011, 4 (02) :153-161
[40]   Effects of freezing and cryopreservation on the mechanical properties of arteries [J].
Venkatasubramanian, Ramji T. ;
Grassl, Erin D. ;
Barocas, Victor H. ;
Lafontaine, Daniel ;
Bischof, John C. .
ANNALS OF BIOMEDICAL ENGINEERING, 2006, 34 (05) :823-832