Metal release and cytotoxicity of different orthodontic bracket-wire combinations: An in vitro study

被引:2
|
作者
Aiswareya, Gunaseelan [1 ]
Verma, Sanjeev K. [1 ]
Khan, Saba [1 ,5 ]
Owais, Mohammad [2 ]
Farooqi, Izharul H. [3 ]
Naseem, Sufia [4 ]
机构
[1] Dr ZA Dent Coll, Dept Orthodont & Dent Anat, Aligarh, India
[2] Aligarh Muslim Univ, Dept Interdisciplinary Biotechnol Unit, Aligarh, India
[3] Aligarh Muslim Univ, Dept Civil Engn, Aligarh, India
[4] Aligarh Muslim Univ, Dept Biochem, Aligarh, India
[5] Aligarh Muslim Univ, Dr ZA Dent Coll, Dept Orthodont & Dent Anat, Aligarh 202001, India
关键词
Ceramic; cytotoxicity; nickel titanium; stainless steel; titanium molybdenum alloy; ORAL-MUCOSA CELLS; APPLIANCES; BIODEGRADATION; CORROSION; VIVO;
D O I
10.4103/jispcd.JISPCD_65_23
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: To quantify and compare the metal ions released from different bracket-wire combinations and to assess their cytotoxicity. Materials and Methods: A total of 360 fabricated sectional fixed orthodontic appliances were divided into 6 groups. The first three groups consisted of stainless-steel brackets with stainless-steel, snickel-titanium (NiTi), and titanium-molybdenum alloy (TMA) archwires, and the other three groups were fabricated using ceramic brackets (polycrystalline alumina) with stainless-steel, NiTi, and TMA archwires. These appliances were immersed in artificial saliva (pH 6.5 +/- 0.5, 37 degrees C), for 1 week, 2 weeks, and 1 month. The nickel and chromium ions released in the artificial saliva were quantified using a flame atomic absorption spectrometer, and cytotoxicity assessment was performed using a 3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyl tetrazolium bromide (MTT) assay on human cervical cancer cell line. Results: The stainless-steel bracket groups displayed a significantly greater release of nickel and chromium ions compared to the ceramic bracket groups (P < 0.05). However, no significant differences were identified when comparing the three archwire types within the stainless-steel/ceramic bracket groups. At the end of 1 month, the % cell viability demonstrated by the appliances was in the decreasing order of stainless-steelTMA > ceramic-stainless steel > stainless-steel-NiTi > ceramic-NiTi > stainless steel-stainless steel > ceramic-TMA. Conclusion: Considerably greater release of nickel and chromium ions was observed from the appliances utilizing stainless steel brackets compared to those employing ceramic brackets. However, no remarkable difference in the levels of nickel and chromium ions was observed when comparing the three archwires: stainless steel, NiTi, and TMA. In the cytotoxicity assessment, the ceramic-TMA combination displayed the highest level of cytotoxicity, while the stainless-steel-TMA combination displayed the least cytotoxicity.
引用
收藏
页码:469 / 476
页数:8
相关论文
共 50 条
  • [21] An in vitro assessment of the influences of different wire materials and bracket systems when correcting dental crowding
    Raphaelli Nahas-Scocate, Ana Carla
    Neves, Marcos Bitencourt
    de Souza, Lucas Torres
    Kasaz, Alline de Cerqueira
    Listik, Eduardo
    Pereira da Silva, Helio Doyle
    Cattaneo, Paolo Maria
    Scocate, Marcos Coral
    Bordin, Dimorvan
    Matias, Murilo
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2020, 31 (11)
  • [22] Cytotoxicity and genotoxicity of orthodontic bands after aging: an in-vitro study
    Karandish, Maryam
    Khademi, Bahar
    Ziaei, Golnaz
    Erfani, Nasrollah
    Moezi, Leila
    Faghih, Zahra
    BMC ORAL HEALTH, 2025, 25 (01):
  • [23] A comparative evaluation of ion release from different commercially-available orthodontic mini-implants - an in-vitro study
    Ananthanarayanan, Venkateswaran
    Padmanabhan, Sridevi
    Chitharanjan, Arun B.
    AUSTRALIAN ORTHODONTIC JOURNAL, 2016, 32 (02) : 165 - 174
  • [24] Cytotoxicity Assessment of Metal and 3D Printed Resin Orthodontic Attachments An in vitro cell culture behavior study
    Nagib, Riham
    Zogorean, Roxana
    Gavriliuc, Oana Isabella
    Szuhanek, Camelia
    Moldoveanu, Bogdan
    Negrutiu, Meda Lavinia
    Sinescu, Cosmin
    Paunescu, Virgil
    Brad, Silviu
    REVISTA DE CHIMIE, 2018, 69 (06): : 1515 - 1518
  • [25] Metal Ion Release from Orthodontic Archwires: A Comparative Study of Biocompatibility and Corrosion Resistance
    Mikulewicz, Marcin
    Suski, Piotr
    Tokarczuk, Oskar
    Warzynska-Maciejewska, Magdalena
    Pohl, Pawel
    Tokarczuk, Beata
    MOLECULES, 2024, 29 (23):
  • [26] Exposure to the oral environment enhances the corrosion of metal orthodontic appliances caused by fluoride-containing products: Cytotoxicity, metal ion release, and surface roughness
    Chantarawaratit, Pintu-on
    Yanisarapan, Tipanan
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2021, 160 (01) : 101 - 112
  • [27] In vitro release of theophylline and cytotoxicity of two new metal-drug complexes
    Hao, Xue-Min
    Zhao, Shuai
    Wang, Hao
    Wu, Yi-Bo
    Yang, Dan
    Zhang, Xiao-Feng
    Xu, Zi-Li
    POLYHEDRON, 2018, 142 : 38 - 42
  • [28] Release of Metal Ions from Orthodontic Appliances by In Vitro Studies: A Systematic Literature Review
    Marcin Mikulewicz
    Katarzyna Chojnacka
    Biological Trace Element Research, 2011, 139 : 241 - 256
  • [29] IN-VITRO RELEASE OF NICKEL AND CHROMIUM FROM DIFFERENT TYPES OF SIMULATED ORTHODONTIC APPLIANCES
    KEROSUO, H
    ODONT, D
    MOE, G
    KLEVEN, E
    ANGLE ORTHODONTIST, 1995, 65 (02) : 111 - 116
  • [30] Comparing Torque Transmission of Different Bracket Systems in Combination with Various Archwires Considering Play in the Bracket Slot: An In Vitro Study
    Wichelhaus, Andrea
    Guggenbuehl, Simon
    Hoetzel, Linus
    Seidel, Corinna L.
    Sabbagh, Hisham
    Hoffmann, Lea
    MATERIALS, 2024, 17 (03)