Changes in fracture energy at FRP-concrete interfaces following indoor and outdoor exposure with sustained loading

被引:4
作者
Lee, Jaeha [1 ]
Artun, Kivanc [2 ,5 ]
Bakis, Charles E. [3 ]
Lopez, Maria M. [2 ,6 ]
Boothby, Thomas E. [4 ]
机构
[1] Korea Maritime & Ocean Univ, Dept Civil Engn, 609 Engn Bldg-II, Busan 49112, South Korea
[2] Penn State Univ, Dept Civil & Environm Engn, 212 Sackett Bldg, University Pk, PA 16802 USA
[3] Penn State Univ, Dept Engn Sci & Mech, 212 Earth Engn Sci Bldg, University Pk, PA 16802 USA
[4] Penn State Univ, Dept Architectural Engn, Engn Unit A 104, University Pk, PA 16802 USA
[5] Ghafari Associates, Chicago, IL 60603 USA
[6] Modjeski & Masters Inc, 100 Sterling Pkwy,Suite 302, Mechanicsburg, PA 17050 USA
基金
美国国家科学基金会; 新加坡国家研究基金会;
关键词
Concrete-FRP interface; Fracture energy; Sustained load; Environmental effects; BOND; DURABILITY; FREEZE; MODEL;
D O I
10.1016/j.conbuildmat.2023.131905
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Small-scale plain concrete precracked beams strengthened with carbon and glass fiber reinforced polymer (FRP) sheets were tested in 3-point flexure to evaluate changes in the FRP-concrete Mode II interfacial fracture energy following sustained loading for 6 and 13 years in indoor and outdoor environments. Mode II fracture energy of the interfacial region, GF, was calculated using strain profiles along the length of the FRP sheet, which were measured using digital image correlation and photoelastic techniques. In the post-conditioned experiments, larger GF values were measured as the debonded zone progressed from the sustained shear stress transfer region to the unstressed portion of the interfacial region far from the notch, particularly in beams with outdoor conditioning. In the interfacial region near the notch, the carbon FRP beams showed no reduction in GF in the indoor environment but reduction in the outdoor environment, while glass FRP showed reductions in both environments. In outdoor beams with glass FRP sheets, GF was not additionally degraded when the FRP was exposed to direct sunlight, in comparison to beams with the FRP exposed to indirect sunlight.
引用
收藏
页数:15
相关论文
共 43 条
  • [1] [Anonymous], 2008, Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures
  • [2] [Anonymous], 2003, E1359 ASTM
  • [3] [Anonymous], 2008, P US S AM WORKSH INN, DOI DOI 10.26207/GWGE-8X50
  • [4] [Anonymous], 2018, C42 ASTM
  • [5] [Anonymous], 2017, D7958 ASTM
  • [6] Artun K., 2012, DURABILITY CONCRETE
  • [7] Durability of Adhesively Bonded FRP-to-Concrete Joints
    Aydin, Hasret
    Gravina, Rebecca J.
    Visintin, Phillip
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2016, 20 (05)
  • [8] Bakis C.E., 2017, P 5 INT C DUR FIB RE
  • [9] Bakis C.E., 2016, ADV OPTICAL METHODS, V3
  • [10] Development of a simple bond-slip model for joints monitored with the DIC technique
    Biscaia, Hugo C.
    Franco, Noel
    Chastre, Carlos
    [J]. ARCHIVES OF CIVIL AND MECHANICAL ENGINEERING, 2018, 18 (04) : 1535 - 1546