Thermal Mapping of Power Modules Using Optical Fibers during AC Power Cycling Tests

被引:0
作者
Zhang, Kaichen [1 ]
Iarmuzzo, Francesco [1 ]
机构
[1] Aalborg Univ, Dept Energy, Ctr Reliable Power Elect CORPE, DK-9220 Aalborg, Denmark
来源
2023 IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, APEC | 2023年
关键词
junction temperature measurement; accelerated power cycling test; reliability; on-line monitoring; JUNCTION-TEMPERATURE-MEASUREMENT; IGBT MODULE;
D O I
10.1109/APEC43580.2023.10131209
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The power cycling withstand capability of power semiconductors is of great interest in determining the component's qualification and reliability performance. Compared to the traditional DC Power cycling test, the AC power cycling test can accelerate the component to fail under more realistic operating conditions. The wear process in the AC power cycling test depends on many parameters, among which the maximum junction temperature T-j, and temperature swing Delta T-j are crucial to be determined. The traditional way in DC power cycling test is to measure the T-j indirectly using the temperature-sensitive electrical parameter (TSEP) method, which is not very applicable during the AC power cycling test as it will increase the circuit complicity and may interrupt the PWM operation. The purpose of this paper is to evaluate a direct junction temperature measurement in an IGBT power module through silicone gel using optical fibers, which enables a fast and accurate T-j determination during AC power cycling. For this purpose, junction temperatures have been measured for both gel-filled modules and gel-removed modules under different experimental conditions. The experimental results presented concern about: the presence of silicone gel's impact on the T-j measurement accuracy, the temperature difference inside the silicone gel while the optical fiber is being instrumented at different positions, and the spatial temperature distributions of the IGBT chip. Future work will also include the comparison of the T-j measurements of a gel-filled power module between using the optical fibers and the well-established TSEP method.
引用
收藏
页码:2630 / 2633
页数:4
相关论文
共 19 条
[1]  
[Anonymous], 2010, 60749342010 IEC
[2]  
Automotive Electronic Council, 2021, AEC Q101 REV E
[3]   Monitoring of Fallow Land in Southern Palatinate Forest Using High Resolution Satellite and LIDAR Data [J].
Bachofer, Felix ;
Hochschild, Volker ;
Schuler, Helmut .
PHOTOGRAMMETRIE FERNERKUNDUNG GEOINFORMATION, 2010, (05) :355-361
[4]   Improved Reliability of Power Modules A Review of Online Junction Temperature Measurement Methods [J].
Baker, Nick ;
Liserre, Marco ;
Dupont, Laurent ;
Avenas, Yvan .
IEEE INDUSTRIAL ELECTRONICS MAGAZINE, 2014, 8 (03) :17-27
[5]  
Brandelero J., 2016, 2016 28 INT S POW SE
[6]   Power cycling test of transfer molded IGBT modules by advanced power cycler under different junction temperature swings [J].
Choi, U. M. ;
Jorgensen, S. ;
Iannuzzo, F. ;
Blaabjerg, F. .
MICROELECTRONICS RELIABILITY, 2018, 88-90 :788-794
[7]   Junction temperature estimation method for a 600 V, 30A IGBT module during converter operation [J].
Choi, U. M. ;
Blaabjerg, F. ;
Iannuzzo, F. ;
Jorgensen, S. .
MICROELECTRONICS RELIABILITY, 2015, 55 (9-10) :2022-2026
[8]   Study on Effect of Junction Temperature Swing Duration on Lifetime of Transfer Molded Power IGBT Modules [J].
Choi, Ui-Min ;
Blaabjerg, Frede ;
Jorgensen, Soren .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (08) :6434-6443
[9]   Power Cycle Testing of Power Switches: A Literature Survey [J].
GopiReddy, Lakshmi Reddy ;
Tolbert, Leon M. ;
Ozpineci, Burak .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (05) :2465-2473
[10]   Requirements in power cycling for precise lifetime estimation [J].
Herold, Christian ;
Franke, Joerg ;
Bhojani, Riteshkumar ;
Schleicher, Andre ;
Lutz, Josef .
MICROELECTRONICS RELIABILITY, 2016, 58 :82-89