Design and application of potentiometric sensors for the determination of mefenamic and phenylanthranilic acids

被引:1
|
作者
Kormosh, Zholt [1 ]
Khalavka, Yuriy [2 ]
Mittal, Susheel K. [3 ]
机构
[1] Lesya Ukrainka Volyn Natl Univ, Dept Chem & Technol, Voli Av 13, UA-43021 Lutsk, Ukraine
[2] Yuriy Fedkovych Chernivtsi Natl Univ, Dept Inorgan Chem Solids & Nanoparticles, Kotsiubynsky Str 2, UA-58012 Chernovtsy, Ukraine
[3] Thapar Univ, Sch Chem & Biochem, Patiala 147004, Punjab, India
关键词
NONSTEROIDAL ANTIINFLAMMATORY DRUGS; ION-SELECTIVE ELECTRODES; SIMULTANEOUS SPECTROPHOTOMETRIC DETERMINATION; MEMBRANE SENSOR; PHARMACEUTICAL FORMULATIONS; COMPLEX; INDOMETHACIN; PARACETAMOL; CONSTANTS; STATE;
D O I
10.1039/d2ay02092k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Characteristics, performance and applications of potentiometric membrane sensors are described for the determination of mefenamic and phenylanthranilic ions. Ion associates of mefenamic, ClO4-, and phenylanthranilic ions with crystal violet (counter-cation) as ion exchange sites have been used as ionophores in the plasticized one- and two-layer membrane ion-selective electrodes. The LOD is reported to be 8.4 x 10(-5) M for mefenamic acid, and 5.1 x 10(-5) M for phenylanthranilic acid. The cations of basic dyes (crystal violet) are characterized by significant delocalization of the positive charge and polarizability. This may explain the better selectivity of the developed sensors. These sensors were used for the direct assay of mefenamic and N-phenylanthranilic acids in model solutions and applications studied in commercial pharmaceutical preparations.
引用
收藏
页码:1903 / 1914
页数:12
相关论文
共 50 条
  • [1] Sensors Based on Single- and Double-Layer Plasticized Membranes for the Potentiometric Determination of Mefenamic and Phenylanthranylic Acids
    Kormosh, Zh A.
    Matviichuk, O. Yu
    Antal, I. P.
    Bazel, Ya R.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 75 (06) : 820 - 828
  • [2] Potentiometric determination of mefenamic acid in pharmaceutical formulation by membrane sensor based on ion-pair with basic dye
    Kormosh, Zholt
    Matviychuk, Oksana
    CHINESE CHEMICAL LETTERS, 2013, 24 (04) : 315 - 317
  • [3] Flow-Through Potentiometric Sensors for Alizarin Red S Dye and Their Application for Aluminum Determination
    Hassan, Saad S. M.
    Kamel, Ayman H.
    Abd El-Naby, Heba
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2014, 61 (02) : 295 - 302
  • [4] Potentiometric sensors for the determination of pharmaceutical drugs
    Mostafa, Islam M.
    Meng, Chengda
    Dong, Zixuan
    Lou, Baohua
    Xu, Guobao
    ANALYTICAL SCIENCES, 2022, 38 (01) : 23 - 37
  • [5] Novel potentiometric sensors for the selective determination of domperidone
    K. Girish Kumar
    Pearl Augustine
    Sareena John
    Journal of Applied Electrochemistry, 2010, 40 : 65 - 71
  • [6] Potentiometric Sensors for the Determination of Anionic Surfactants - A Review
    Jozanovic, Marija
    Sakac, Nikola
    Karnas, Maja
    Medvidovic-Kosanovic, Martina
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2021, 51 (02) : 115 - 137
  • [7] Fabrication of potentiometric sensors for the selective determination of ketoconazole
    Kumar, K. Girish
    Augustine, Pearl
    John, Sareena
    Radecki, Jerzi
    Radecka, Hanna
    ANALYTICAL LETTERS, 2008, 41 (07) : 1144 - 1157
  • [8] Potentiometric Sensors and Multisensor Systems for the Determination of Lanthanides
    I. S. Yaroshenko
    M. Yu. Alyapyshev
    V. A. Babain
    A. V. Legin
    D. O. Kirsanov
    Journal of Analytical Chemistry, 2019, 74 : 1003 - 1018
  • [9] Potentiometric Sensors for Iron(III) Cations Determination
    Paut, Andrea
    Prkic, Ante
    Mitar, Ivana
    Guc, Lucija
    KEMIJA U INDUSTRIJI-JOURNAL OF CHEMISTS AND CHEMICAL ENGINEERS, 2023, 72 (5-6): : 359 - 368
  • [10] Potentiometric Sensors and Multisensor Systems for the Determination of Lanthanides
    Yaroshenko, I. S.
    Alyapyshev, M. Yu.
    Babain, V. A.
    Legin, A. V.
    Kirsanov, D. O.