Outcomes of rotating versus pure hinge knee arthroplasty in the setting of one-stage exchange for periprosthetic joint infection

被引:2
作者
Liechti, Emanuel F. [1 ,2 ]
Linke, Philip [1 ]
Gehrke, Thorsten [1 ]
Citak, Mustafa [1 ]
Lausmann, Christian [1 ]
机构
[1] Helios ENDO Klin Hamburg, Dept Orthopaed Surg, Holstenstr 2, D-22767 Hamburg, Germany
[2] Univ Bern, Bern Univ Hosp, Dept Orthopaed Surg & Traumatol, Inselspital, Bern, Switzerland
关键词
Knee arthroplasty; Revision arthroplasty; One-stage septic exchange; Periprosthetic joint infection; Hinge knee prosthesis; DISLOCATION; PROSTHESES; SALVAGE; FAILURE; REPLACEMENT; IMPLANTS; DESIGN;
D O I
10.1007/s00264-024-06139-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeRotating or pure hinge knee prostheses are often used in case of periprosthetic joint infection (PJI). Five-year survival data of rotating hinge implants ranging from 52 to 90%, whereas pure hinge data are sparse. This study describes the results of both hinge knee prostheses after one-stage septic exchange.MethodsOne hundred sixty-seven one-stage septic exchanges of a primary unconstrained total knee arthroplasty (TKA) to a cemented hinge prosthesis (117 rotating and 50 pure hinge TKAs) performed between 2008 and 2017 were retrospectively reviewed. Exclusion criteria were stem extensions or augments used in primary TKA, history of extensor mechanism reconstruction, and a follow-up less than two years after surgery. Rates of reinfection, mechanical failures, and all-cause revision-free survival data were documented.ResultsAt five years, the all-cause revision-free survival was 77% (95% CI 69 to 82). Thirty-one patients (19%) had further revision for aseptic reasons. In the rotating hinge group, the mechanical failure rate was more than twice as high as in the pure hinge group (13% vs 6%), significantly influenced by higher body weight. At a mean follow-up of 6.7 years, 21 (13%) patients had a reinfection and underwent a further surgery. Reinfection rates did not differ between the two groups.ConclusionThe use of hinge TKA in the revision of PJI shows favourable five year infection-free and all-cause revision-free survival rates of 91% and 77%, respectively. Our study showed poorer results of the rotating hinge design. These results may help surgeons to choose proper implants in case of septic knee revision.
引用
收藏
页码:1689 / 1690
页数:2
相关论文
共 31 条
  • [1] Results With 98 Endo-Modell Rotating Hinge Prostheses for Primary Knee Arthroplasty
    Bistolfi, Alessandro
    Lustig, Sebabastien
    Rosso, Federica
    Dalmasso, Paola
    Crova, Maurizio
    Massazza, Giuseppe
    [J]. ORTHOPEDICS, 2013, 36 (06) : E746 - E752
  • [2] Case Report: Failure of Rotating-hinge Total Knee Prosthesis by Disengagement of the Hinge-post Extension
    Biswas, Debdut
    Haughom, Bryan
    Mayle, Robert E., Jr.
    Della Valle, Craig J.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (04) : 1389 - 1392
  • [3] Rotating Hinge Knee Arthroplasty for Revision Prosthetic-Knee Infection: Good Functional Outcomes but a Crucial Need for Superinfection Prevention
    Bourbotte-Salmon, Florian
    Ferry, Tristan
    Cardinale, Mickael
    Servien, Elvire
    Rongieras, Frederic
    Fessy, Michel-Henry
    Bertani, Antoine
    Laurent, Frederic
    Buffe-Lidove, Margaux
    Batailler, Cecile
    Lustig, Sebastien
    [J]. FRONTIERS IN SURGERY, 2021, 8
  • [4] Total knee arthroplasty using hinge joints: Indications and results
    Carlos Rodriguez-Merchan, E.
    [J]. EFORT OPEN REVIEWS, 2019, 4 (04): : 121 - 132
  • [5] A novel radiological classification system of the distal femur
    Citak, Mustafa
    Levent, Ali
    Suero, Eduardo M.
    Rademacher, Kristof
    Busch, Sophia-Marlene
    Gehrke, Thorsten
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (02) : 315 - 322
  • [6] Long-Term Results After Total Knee Arthroplasty with Contemporary Rotating-Hinge Prostheses
    Cottino, Umberto
    Abdel, Matthew P.
    Perry, Kevin I.
    Mara, Kristin C.
    Lewallen, David G.
    Hanssen, Arlen D.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2017, 99 (04) : 324 - 330
  • [7] The role of the rotating hinge prosthesis in the salvage arthroplasty setting
    Deehan, David John
    Murray, James
    Birdsall, Paul D.
    Holland, James P.
    Pinder, Ian M.
    [J]. JOURNAL OF ARTHROPLASTY, 2008, 23 (05) : 683 - 688
  • [8] Dislocation of rotating-hinge total knee arthroplasty
    Encinas-Ullan, Carlos A.
    Gomez-Cardero, Primitivo
    Ruiz-Perez, Juan S.
    Carlos Rodriguez-Merchan, E.
    [J]. EFORT OPEN REVIEWS, 2021, 6 (02) : 107 - 112
  • [9] Intermediate-Term Results of 142 Single-Design, Rotating-Hinge Implants: Frequent Complications May Not Preclude Salvage of Severely Affected Knees
    Farid, Yasser R.
    Thakral, Rishi
    Finn, Henry A.
    [J]. JOURNAL OF ARTHROPLASTY, 2015, 30 (12) : 2173 - 2180
  • [10] FINN HA, 1991, CLIN ORTHOP RELAT R, P108