Oxovanadium(IV) heteromacrocyclic complexes as ionophores for iodide-selective electrodes

被引:0
作者
Moriuchi-Kawakami, Takayo [1 ]
Higashikado, Akihisa [1 ]
Hirahara, Masanari [1 ]
Fujimori, Keiichi [1 ]
Moriuchi, Toshiyuki [2 ]
机构
[1] Osaka Inst Technol, Fac Engn, Dept Appl Chem, 5-16-1 Omiya, Asahi, Osaka 5358585, Japan
[2] Osaka Metropolitan Univ, Grad Sch Sci, Dept Chem, 3-3-138 Sugimoto,Sumiyoshi Ku, Osaka 5588585, Japan
关键词
iodide ions; ion-selective electrodes; oxovanadium(IV) complexes; MEMBRANE ELECTRODES; POTENTIOMETRIC SELECTIVITY; MOLECULAR-STRUCTURE; BULK OPTODES; PORPHYRINS; THIOCYANATE; DERIVATIVES;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Highly selective poly(vinyl chloride) (PVC) membrane electrodes, based on oxovanadium(IV) complexes of heteromacrocyclic compounds as new iodide-selective ionophores for ion-selective electrodes (ISEs), were fabricated with a composition of PVC (28.1 wt%), plasticizers (69.3 wt%), ionophores (2.6 wt%), and cation excluders (15 mol% relative to the ionophore). The electrode prepared from oxovanadium(IV) tetraphenyl porphyrin with 2-nitrophenyl octyl ether (o-NPOE) as the membrane solvent and tetradodecylammonium chloride (TDDACl) as the cation excluder was found to exhibit the best sensitivity over a wide concentration range from 5.0 x 10-7 to 2.1 x 10-2 M with a Nernstian response of -59.02 mV per decade and the highest ion-selectivity toward I- ions over perchlorate ions (I-/ClO4- = 91). Graphical Abstract Heteromacrocyclic complexes of vanadium(IV) oxide were developed as ionophores for ionselective electrodes (ISEs). The ISE based on oxovanadium(IV) tetraphenyl porphyrin using o-NPOE as the membrane solvent and TDDACl as the cation excluders was found to exhibit the best sensitivity toward the I- ions over a wide concentration range with a Nernstian response and the highest ion-selectivity toward the I- ions over perchlorate ions.
引用
收藏
页数:5
相关论文
共 46 条
[1]  
Akinori J., 1974, Bull. Chem. Soc. Jpn, V47, P2862
[2]  
Ales H., 1989, Anal. Chem, V61, P1169
[3]   A generalized model for apparently "non-Nernstian" equilibrium responses of ionophore-based ion-selective electrodes.: 1.: Independent complexation of the ionophore with primary and secondary ions [J].
Amemiya, S ;
Bühlmann, P ;
Odashima, K .
ANALYTICAL CHEMISTRY, 2003, 75 (14) :3329-3339
[4]  
[Anonymous], 1888, Pathol. Pharmakol
[5]   ROLE OF SOLVENT-EXTRACTION PARAMETERS IN GOVERNING POTENTIAL SELECTIVITY OF LIQUID MEMBRANE ELECTRODES [J].
BACK, S ;
SANDBLOM, J .
ANALYTICAL CHEMISTRY, 1973, 45 (09) :1680-1684
[6]   Fluoride-selective optical sensor based on aluminum(III) - Octaethylporphyrin in thin polymeric film: Further characterization and practical application [J].
Badr, IHA ;
Meyerhoff, ME .
ANALYTICAL CHEMISTRY, 2005, 77 (20) :6719-6728
[7]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[8]   MN(III) PORPHYRIN-BASED THIOCYANATE-SELECTIVE MEMBRANE ELECTRODES - CHARACTERIZATION AND APPLICATION IN FLOW-INJECTION DETERMINATION OF THIOCYANATE IN SALIVA [J].
BROWN, DV ;
CHANIOTAKIS, NA ;
LEE, IH ;
MA, SC ;
PARK, SB ;
MEYERHOFF, ME ;
NICK, RJ ;
GROVES, JT .
ELECTROANALYSIS, 1989, 1 (06) :477-484
[9]   Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors [J].
Buhlmann, P ;
Pretsch, E ;
Bakker, E .
CHEMICAL REVIEWS, 1998, 98 (04) :1593-1687
[10]  
Cattrall R. W., 1997, Chemical Sensors (Oxford Chemistry Primers, 52)