Implementation of electrical impedance tomography

被引:0
|
作者
Levin, A. I. [1 ]
Pecherskaya, E. A. [1 ]
Varenik, Yu. A. [2 ]
Shepeleva, J. V. [1 ]
机构
[1] Penza State Univ, Penza, Russia
[2] Penza State Univ Architecture & Construct, Penza, Russia
关键词
EIT; ADC; biological object; impedance;
D O I
10.18721/JPM.163.250
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The method of electrical impedance tomography, which calculates images of the electrical conductivity inside the body based on surface measurements is considered. The basis of the method is an alternating electric current, which is supplied to various configurations of injecting and detecting electrodes located on the body surface and the potential field that arises in its volume is measured. It is shown that each link of the hardware that implements the electrical impedance tomography method has an impact on the final visualization. The implementation essence of the software part of the method based on the Laplace equation is stated. It is advisable to use the results of the work when monitoring the respiratory and cardiovascular systems using a chest belt with electrodes.
引用
收藏
页码:288 / 293
页数:6
相关论文
共 50 条
  • [21] THE SENSITIVITY IN ELECTRICAL IMPEDANCE TOMOGRAPHY
    Rybin, A. I.
    Gaydayenko, E. V.
    Sushko, I. O.
    Gamanenko, A. I.
    VISNYK NTUU KPI SERIIA-RADIOTEKHNIKA RADIOAPARATOBUDUVANNIA, 2013, (55): : 107 - 117
  • [22] Electrical impedance tomography - Preface
    Barber, DC
    PHYSIOLOGICAL MEASUREMENT, 1996, 17 : U5 - U5
  • [23] Chest electrical impedance tomography
    Grigoriadis, K.
    Armaganidis, A.
    ARCHIVES OF HELLENIC MEDICINE, 2019, 36 (05): : 589 - 596
  • [24] A phantom for electrical impedance tomography
    Griffiths, H.
    Clinical Physics and Physiological Measurement, 1988, 9 (SUPPL. A): : 15 - 20
  • [25] An electrical impedance tomography microscope
    Griffiths, H.
    Tucker, M.G.
    Sage, J.
    Herrenden-Harker, W.G.
    1996, Institute of Physics Publishing (17)
  • [26] An electrical impedance tomography microscope
    Griffiths, H
    Tucker, MG
    Sage, J
    HerrendenHarker, WG
    PHYSIOLOGICAL MEASUREMENT, 1996, 17 : A15 - A24
  • [27] Rotational electrical impedance tomography
    Huang, Cheng-Ning
    Yu, Fang-Ming
    Chung, Hung-Yuan
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2007, 18 (09) : 2958 - 2966
  • [28] A electrical impedance tomography system
    Peng, Y
    Mo, YL
    IEEE EMBS APBME 2003, 2003, : 280 - 281
  • [29] Electrical Impedance Tomography of Electrolysis
    Meir, Arie
    Rubinsky, Boris
    PLOS ONE, 2015, 10 (06):
  • [30] ELECTRICAL-IMPEDANCE TOMOGRAPHY
    不详
    SEMAINE DES HOPITAUX, 1993, 69 (28): : 855 - 855