Single Source-Detector Separation Approach to Calculate Tissue Oxygen Saturation Using Continuous Wave Near-Infrared Spectroscopy

被引:1
|
作者
Nguyen, Thien [1 ]
Park, Soongho [1 ]
Hill, Brian [1 ]
Gandjbakhche, Amir H. H. [1 ]
机构
[1] NIH, Eunice Kennedy Shriver Natl Inst Child Hlth & Huma, Bethesda, MD 20892 USA
来源
IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY | 2023年 / 4卷
关键词
Near-infrared spectroscopy; StO(2); multiwavelength; wearable; in-vivo; OXIMETRY;
D O I
10.1109/OJEMB.2023.3246929
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Currently, common optical techniques to measure tissue oxygen saturation (StO(2)) include time domain (TD), frequency domain (FD), and continuous wave (CW) near-infrared spectroscopy (NIRS). While TD-and FD-NIRS can provide absolute hemoglobin concentration, these systems are often complex and expensive. CW-NIRS, such as diffuse reflectance spectroscopy and spatially resolved spectroscopy (SRS), are simpler and more affordable, but they still require at least two source-detector separations. Here, we propose a single source-detector separation (SSDS) approach to measure StO(2) using reflected intensities from three wavelengths. The accuracy of the SSDS-based StO(2) measurement was verified using an optical simulation and an in-vivo experiment. Simulated spatially dependent reflectance was generated using the Virtual Tissue Simulator on a 1-layer model, which has StO(2) ranging from 0% to 100%. SSDS calculation yielded an equivalent StO(2) to the actual value (average error = 0.3% +/- 0.5%). We then performed StO(2) measurements on seven healthy volunteers in the prefrontal cortex during a simulated hypercapnia test using a CW-NIRS device. This device consists of a light source and two photodetectors, which are 30 mm and 40 mm away from the light source. The cerebral oxygen saturation was calculated using both the SRS approach, which uses the reflected intensities at both separations, and the SSDS approach, which employs the reflected intensities at either 30 mm or 40 mm separation. The SRS-based StO(2) calculation was similar to the value calculated from the SSDS method (average difference = 5.0% +/- 1.1%). This proposed method will help to advance the development of miniaturized technologies to monitor StO(2) continuously.
引用
收藏
页码:79 / 84
页数:6
相关论文
共 50 条
  • [1] A broadband multi-distance approach to measure tissue oxygen saturation with continuous wave near-infrared spectroscopy
    Kovacsova, Zuzana
    Bale, Gemma
    Veesa, Joshua Deepak
    Dehghani, Hamid
    Tachtsidis, Ilias
    DIFFUSE OPTICAL SPECTROSCOPY AND IMAGING VII, 2019, 11074
  • [2] Short-channel functional near-infrared spectroscopy regressions improve when source-detector separation is reduced
    Goodwin, James R.
    Gaudet, Chantel R.
    Berger, Andrew J.
    NEUROPHOTONICS, 2014, 1 (01)
  • [3] Reference Range for Tissue Oxygen Saturation in Pregnancy Using Near-Infrared Spectroscopy
    Stager, Robert D.
    Fakih, Mona A.
    Churley-Strom, Ruth
    Singal, Bonita
    Purtill, Mary-Anne
    JOURNAL OF REPRODUCTIVE MEDICINE, 2015, 60 (3-4) : 149 - 154
  • [4] Continuous-wave near-infrared spectroscopy is not related to brain tissue oxygen tension
    Kerz, Thomas
    Beyer, Christian
    Huthmann, Alexandra
    Kalasauskas, Darius
    Amr, Amr Nimer
    Boor, Stephan
    Welschehold, Stefan
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2016, 30 (05) : 641 - 647
  • [5] Continuous-wave near-infrared spectroscopy is not related to brain tissue oxygen tension
    Thomas Kerz
    Christian Beyer
    Alexandra Huthmann
    Darius Kalasauskas
    Amr Nimer Amr
    Stephan Boor
    Stefan Welschehold
    Journal of Clinical Monitoring and Computing, 2016, 30 : 641 - 647
  • [6] In-vivo quantitative measurement of tissue oxygen saturation of human webbing using a transmission type continuous-wave near-infrared spectroscopy
    Aizimu, Tuerxun
    Adachi, Makoto
    Nakano, Kazuya
    Ohnishi, Takashi
    Nakaguchi, Toshiya
    Takahashi, Nozomi
    Nakada, Taka-aki
    Oda, Shigeto
    Haneishi, Hideaki
    OPTICAL DIAGNOSTICS AND SENSING XVIII: TOWARD POINT-OF-CARE DIAGNOSTICS, 2018, 10501
  • [7] Multivariate calibration modeling of liver oxygen saturation using near-infrared spectroscopy
    Cingo, NA
    Soller, BR
    Puyana, JC
    BIOMEDICAL DIAGNOSTIC, GUIDANCE, AND SURGICAL-ASSIST SYSTEMS II, 2000, 3911 : 230 - 236
  • [8] Measurement of brain tissue oxygen saturation in term infants using a new portable near-infrared spectroscopy device
    Watanabe, Takaaki
    Ito, Masato
    Miyake, Fuyu
    Ogawa, Ryo
    Tamura, Masanori
    Namba, Fumihiko
    PEDIATRICS INTERNATIONAL, 2017, 59 (02) : 167 - 170
  • [9] Reference values for triceps surae tissue oxygen saturation by near-infrared spectroscopy
    Faria, Valeria C.
    Lemos de Oliveira, Luciano Fonseca
    Ferreira, Ana Paula
    Cunha, Tulio E. O.
    Fernandes, Juliana S. A.
    Pussieldi, Guilherme A.
    Pereira, Danielle A. G.
    PHYSIOLOGICAL MEASUREMENT, 2022, 43 (10)
  • [10] A validation method for near-infrared spectroscopy based tissue oximeters for cerebral and somatic tissue oxygen saturation measurements
    Benni, Paul B.
    MacLeod, David
    Ikeda, Keita
    Lin, Hung-Mo
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2018, 32 (02) : 269 - 284