Advancement in the Cuffless and Noninvasive Measurement of Blood Pressure: A Review of the Literature and Open Challenges

被引:12
作者
Mamun, Mohammad Mahbubur Rahman Khan [1 ]
Sherif, Ahmed [2 ]
机构
[1] Tennessee Technol Univ, Dept Elect & Comp Engn, Cookeville, TN 38505 USA
[2] Univ Southern Mississippi, Sch Comp Sci & Comp Engn, Hattiesburg, MS 39406 USA
来源
BIOENGINEERING-BASEL | 2023年 / 10卷 / 01期
关键词
cuffless blood pressure; hypertension; photoplethysmography; electrocardiogram; machine learning; deep learning;
D O I
10.3390/bioengineering10010027
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Hypertension is a chronic condition that is one of the prominent reasons behind cardiovascular disease, brain stroke, and organ failure. Left unnoticed and untreated, the deterioration in a health condition could even result in mortality. If it can be detected early, with proper treatment, undesirable outcomes can be avoided. Until now, the gold standard is the invasive way of measuring blood pressure (BP) using a catheter. Additionally, the cuff-based and noninvasive methods are too cumbersome or inconvenient for frequent measurement of BP. With the advancement of sensor technology, signal processing techniques, and machine learning algorithms, researchers are trying to find the perfect relationships between biomedical signals and changes in BP. This paper is a literature review of the studies conducted on the cuffless noninvasive measurement of BP using biomedical signals. Relevant articles were selected using specific criteria, then traditional techniques for BP measurement were discussed along with a motivation for cuffless measurement use of biomedical signals and machine learning algorithms. The review focused on the progression of different noninvasive cuffless techniques rather than comparing performance among different studies. The literature survey concluded that the use of deep learning proved to be the most accurate among all the cuffless measurement techniques. On the other side, this accuracy has several disadvantages, such as lack of interpretability, computationally extensive, standard validation protocol, and lack of collaboration with health professionals. Additionally, the continuing work by researchers is progressing with a potential solution for these challenges. Finally, future research directions have been provided to encounter the challenges.
引用
收藏
页数:28
相关论文
共 236 条
  • [1] Acciaroli G, 2018, IEEE ENG MED BIO, P3630, DOI 10.1109/EMBC.2018.8512944
  • [2] Age-related changes in peripheral pulse timing characteristics at the ears, fingers and toes
    Allen, J
    Murray, A
    [J]. JOURNAL OF HUMAN HYPERTENSION, 2002, 16 (10) : 711 - 717
  • [3] Photoplethysmography and its application in clinical physiological measurement
    Allen, John
    [J]. PHYSIOLOGICAL MEASUREMENT, 2007, 28 (03) : R1 - R39
  • [5] A Review of Noninvasive Methodologies to Estimate the Blood Pressure Waveform
    Athaya, Tasbiraha
    Choi, Sunwoong
    [J]. SENSORS, 2022, 22 (10)
  • [6] An Estimation Method of Continuous Non-Invasive Arterial Blood Pressure Waveform Using Photoplethysmography: A U-Net Architecture-Based Approach
    Athaya, Tasbiraha
    Choi, Sunwoong
    [J]. SENSORS, 2021, 21 (05) : 1 - 18
  • [7] Availability and affordability of blood pressure-lowering medicines and the effect on blood pressure control in high-income, middle-income, and low-income countries: an analysis of the PURE study data
    Attaei, Marjan W.
    Khatib, Rasha
    McKee, Martin
    Lear, Scott
    Dagenais, Gilles
    Igumbor, Ehimario U.
    AlHabib, Khalid F.
    Kaur, Manmeet
    Kruger, Lanthe
    Teo, Koon
    Lanas, Fernando
    Yusoff, Khalid
    Oguz, Aytekin
    Gupta, Rajeev
    Yusufali, Afzalhussein M.
    Bahonar, Ahmad
    Kutty, Raman
    Rosengren, Annika
    Mohan, Viswanathan
    Avezum, Alvaro
    Yusuf, Rita
    Szuba, Andrzej
    Rangarajan, Sumathy
    Chow, Clara
    Yusuf, Salim
    [J]. LANCET PUBLIC HEALTH, 2017, 2 (09) : E411 - E419
  • [8] Oscillometric measurement of systolic and diastolic blood pressures validated in a physiologic mathematical model
    Babbs, Charles F.
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2012, 11
  • [9] Detecting Pulse from Head Motions in Video
    Balakrishnan, Guha
    Durand, Fredo
    Guttag, John
    [J]. 2013 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2013, : 3430 - 3437
  • [10] Bera Tushar Kanti, 2014, J Med Eng, V2014, P381251, DOI 10.1155/2014/381251