Impact of Phantom Size on Low-Energy Virtual Monoenergetic Images of Three Dual-Energy CT Platforms

被引:5
|
作者
Greffier, Joel [1 ]
Van Ngoc Ty, Claire [2 ]
Fitton, Isabelle [2 ]
Frandon, Julien [1 ]
Beregi, Jean-Paul [1 ]
Dabli, Djamel [1 ]
机构
[1] Montpellier Univ, Nimes Univ Hosp, Dept Med Imaging, IMAGINE UR UM 103, F-30029 Nimes, France
[2] Univ Paris, Hop Europeen Georges Pompidou, AP HP, Dept Radiol, F-75015 Paris, France
关键词
dual-energy; multidetector computed tomography; task-based image quality assessment; split-filter; RECONSTRUCTION;
D O I
10.3390/diagnostics13193039
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to compare the quality of low-energy virtual monoenergetic images (VMIs) obtained with three Dual-Energy CT (DECT) platforms according to the phantom diameter. Three sections of the Mercury Phantom 4.0 were scanned on two generations of split-filter CTs (SFCT-1st and SFCT-2nd) and on one Dual-source CT (DSCT). The noise power spectrum (NPS), task-based transfer function (TTF), and detectability index (d') were assessed on VMIs from 40 to 70 keV. The highest noise magnitude values were found with SFCT-1st and noise magnitude was higher with DSCT than with SFCT-2nd for 26 cm (10.2% +/- 1.3%) and 31 cm (7.0% +/- 2.5%), and the opposite for 36 cm (-4.2% +/- 2.5%). The highest average NPS spatial frequencies and TTF values at 50% (f50) values were found with DSCT. For all energy levels, the f50 values were higher with SFCT-2nd than SFCT-1st for 26 cm (3.2% +/- 0.4%) and the opposite for 31 cm (-6.9% +/- 0.5%) and 36 cm (-5.6% +/- 0.7%). The lowest d' values were found with SFCT-1st. For all energy levels, the d' values were lower with DSCT than with SFCT-2nd for 26 cm (-6.2% +/- 0.7%), similar for 31 cm (-0.3% +/- 1.9%) and higher for 36 cm (5.4% +/- 2.7%). In conclusion, compared to SFCT-1st, SFCT-2nd exhibited a lower noise magnitude and higher detectability values. Compared with DSCT, SFCT-2nd had a lower noise magnitude and higher detectability for the 26 cm, but the opposite was true for the 36 cm.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Noise-optimised virtual monoenergetic imaging of dual-energy CT: effect on metal artefact reduction in patients with lumbar internal fixation
    Zeng, Yanwei
    Deng, Kai
    Yang, Haitao
    Tan, Yi
    Liu, Jun
    Geng, Daoying
    Zhang, Jun
    EUROPEAN SPINE JOURNAL, 2019, 28 (08) : 1783 - 1792
  • [32] Dual-energy CT of the brain: Comparison between DECT angiography-derived virtual unenhanced images and true unenhanced images in the detection of intracranial haemorrhage
    Bonatti, Matteo
    Lombardo, Fabio
    Zamboni, Giulia A.
    Pernter, Patrizia
    Mucelli, Roberto Pozzi
    Bonatti, Giampietro
    EUROPEAN RADIOLOGY, 2017, 27 (07) : 2690 - 2697
  • [33] PHYSICALLY MEANINGFUL VIRTUAL UNENHANCED IMAGE RECONSTRUCTION FROM DUAL-ENERGY CT
    Maddah, Mahnaz
    Mendonca, Paulo R. S.
    Bhotika, Rahul
    2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 808 - 811
  • [34] Impact of covariance modeling in dual-energy spectral CT image reconstruction
    Liu, Yan
    Yu, Zhou
    Zou, Yu
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [35] Virtual Monoenergetic Images (VMI plus ) in Dual-Source Dual-Energy CT Venography (DSDE-CTV) of the Lower Extremity Prior to Coronary Artery Bypass Graft (CABG): A Feasibility Study
    Schmoee, Jonas
    Dirrichs, Timm
    Fehrenbacher, Kerstin
    Tietz, Eric
    Hardt, Felix
    Schmid, Michael
    Gohmann, Robin Fabian
    Reinartz, Sebastian Daniel
    ACADEMIC RADIOLOGY, 2020, 27 (09) : 1249 - 1254
  • [36] Performance of dual layer dual energy CT virtual monoenergetic images to identify early ischemic changes in patients with anterior circulation large vessel occlusion
    Stahl, Fredrik
    Gontu, Vamsi
    Almqvist, Hakan
    Mazya, Michael, V
    Delgado, Anna Falk
    JOURNAL OF NEURORADIOLOGY, 2021, 48 (02) : 75 - 81
  • [37] Carotid and cerebrovascular dual-energy computed tomography angiography: Optimization of window settings for virtual monoenergetic imaging reconstruction
    D'Angelo, Tommaso
    Lenga, Lukas
    Arendt, Christophe T.
    Bucher, Andreas M.
    Peterke, Julia L.
    Caruso, Damiano
    Mazziotti, Silvio
    Ascenti, Giorgio
    Blandino, Alfredo
    Othman, Ahmed E.
    Martin, Simon S.
    Albrecht, Moritz H.
    Bodelle, Boris
    Vogl, Thomas J.
    Wichmann, Julian L.
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 130
  • [38] Low-Energy Virtual Monochromatic Dual-Energy Computed Tomography Images for the Evaluation of Head and Neck Squamous Cell Carcinoma: A Study of Tumor Visibility Compared With Single-Energy Computed Tomography and User Acceptance
    Forghani, Reza
    Kelly, Hillary
    Yu, Eugene
    Belair, Manon
    Letourneau-Guillon, Laurent
    Le, Huy
    Proulx, Francesca
    Ong, Thomas
    Tan, Xianming
    Curtin, Hugh D.
    Levental, Mark
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (04) : 565 - 571
  • [39] Dual-Energy Low-keV or Single-Energy Low-kV CT for Endoleak Detection? A 6-Reader Study in an Aortic Aneurysm Phantom
    Skawran, Stephan
    Angst, Florian
    Bluthgen, Christian
    Eberhard, Matthias
    Kalin, Pascal
    Kobe, Adrian
    Nagy, Daniel
    Szucs-Farkas, Zsolt
    Alkadhi, Hatem
    Euler, Andre
    INVESTIGATIVE RADIOLOGY, 2020, 55 (01) : 45 - 52
  • [40] Impact of iterative reconstructions on image quality and detectability of focal liver lesions in low-energy monochromatic images
    Greffier, J.
    Frandon, J.
    Hamard, A.
    Teissier, J. M.
    Pasquier, H.
    Beregi, J. P.
    Dabli, D.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 77 : 36 - 42