Impact of Phantom Size on Low-Energy Virtual Monoenergetic Images of Three Dual-Energy CT Platforms

被引:5
|
作者
Greffier, Joel [1 ]
Van Ngoc Ty, Claire [2 ]
Fitton, Isabelle [2 ]
Frandon, Julien [1 ]
Beregi, Jean-Paul [1 ]
Dabli, Djamel [1 ]
机构
[1] Montpellier Univ, Nimes Univ Hosp, Dept Med Imaging, IMAGINE UR UM 103, F-30029 Nimes, France
[2] Univ Paris, Hop Europeen Georges Pompidou, AP HP, Dept Radiol, F-75015 Paris, France
关键词
dual-energy; multidetector computed tomography; task-based image quality assessment; split-filter; RECONSTRUCTION;
D O I
10.3390/diagnostics13193039
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to compare the quality of low-energy virtual monoenergetic images (VMIs) obtained with three Dual-Energy CT (DECT) platforms according to the phantom diameter. Three sections of the Mercury Phantom 4.0 were scanned on two generations of split-filter CTs (SFCT-1st and SFCT-2nd) and on one Dual-source CT (DSCT). The noise power spectrum (NPS), task-based transfer function (TTF), and detectability index (d') were assessed on VMIs from 40 to 70 keV. The highest noise magnitude values were found with SFCT-1st and noise magnitude was higher with DSCT than with SFCT-2nd for 26 cm (10.2% +/- 1.3%) and 31 cm (7.0% +/- 2.5%), and the opposite for 36 cm (-4.2% +/- 2.5%). The highest average NPS spatial frequencies and TTF values at 50% (f50) values were found with DSCT. For all energy levels, the f50 values were higher with SFCT-2nd than SFCT-1st for 26 cm (3.2% +/- 0.4%) and the opposite for 31 cm (-6.9% +/- 0.5%) and 36 cm (-5.6% +/- 0.7%). The lowest d' values were found with SFCT-1st. For all energy levels, the d' values were lower with DSCT than with SFCT-2nd for 26 cm (-6.2% +/- 0.7%), similar for 31 cm (-0.3% +/- 1.9%) and higher for 36 cm (5.4% +/- 2.7%). In conclusion, compared to SFCT-1st, SFCT-2nd exhibited a lower noise magnitude and higher detectability values. Compared with DSCT, SFCT-2nd had a lower noise magnitude and higher detectability for the 26 cm, but the opposite was true for the 36 cm.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Comparison of the spectral performance between two dual-source CT systems on low-energy virtual monoenergetic images: A phantom study
    Greffier, Joel
    Faby, Sebastian
    Pastor, Maxime
    Frandon, Julien
    Erath, Julien
    Beregi, Jean-Paul
    Dabli, Djamel
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 124
  • [2] Comparison of low-energy virtual monoenergetic images between photon-counting CT and energy-integrating detectors CT: A phantom study
    Greffier, Joel
    Faby, Sebastian
    Pastor, Maxime
    Frandon, Julien
    Erath, Julien
    Beregi, Jean Paul
    Dabli, Djamel
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2024, 105 (09) : 311 - 318
  • [3] Phantom task-based image quality assessment of three generations of rapid kV-switching dual-energy CT systems on virtual monoenergetic images
    Greffier, Joel
    Viry, Anais
    Barbotteau, Yves
    Frandon, Julien
    Loisy, Maeliss
    de Oliveira, Fabien
    Beregi, Jean Paul
    Dabli, Djamel
    MEDICAL PHYSICS, 2022, 49 (04) : 2233 - 2244
  • [4] Virtual monoenergetic dual-layer dual-energy CT images in colorectal cancer: CT diagnosis could be improved?
    Arico, Francesco Marcello
    Trimarchi, Renato
    Portaluri, Antonio
    Barilla, Claudia
    Migliaccio, Nicola
    Bucolo, Giuseppe Mauro
    Cicero, Giuseppe
    Sofia, Carmelo
    Booz, Christian
    Vogl, Thomas J. J.
    Marino, Maria Adele
    Ascenti, Velio
    D'Angelo, Tommaso
    Mazziotti, Silvio
    Ascenti, Giorgio
    RADIOLOGIA MEDICA, 2023, 128 (08): : 891 - 899
  • [5] Robustness of radiomics features of virtual unenhanced and virtual monoenergetic images in dual-energy CT among different imaging platforms and potential role of CT number variability
    Zhong, Jingyu
    Pan, Zilai
    Chen, Yong
    Wang, Lingyun
    Xia, Yihan
    Wang, Lan
    Li, Jianying
    Lu, Wei
    Shi, Xiaomeng
    Feng, Jianxing
    Yan, Fuhua
    Zhang, Huan
    Yao, Weiwu
    INSIGHTS INTO IMAGING, 2023, 14 (01)
  • [6] Robustness of radiomics features of virtual unenhanced and virtual monoenergetic images in dual-energy CT among different imaging platforms and potential role of CT number variability
    Jingyu Zhong
    Zilai Pan
    Yong Chen
    Lingyun Wang
    Yihan Xia
    Lan Wang
    Jianying Li
    Wei Lu
    Xiaomeng Shi
    Jianxing Feng
    Fuhua Yan
    Huan Zhang
    Weiwu Yao
    Insights into Imaging, 14
  • [7] Virtual monoenergetic images from dual-energy CT: systematic assessment of task-based image quality performance
    Cester, Davide
    Eberhard, Matthias
    Alkadhi, Hatem
    Euler, Andre
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (01) : 726 - +
  • [8] Deep-learning-based direct synthesis of low-energy virtual monoenergetic images with multi-energy CT
    Gong, Hao
    Marsh, Jeffrey F.
    D'Souza, Karen N.
    Huber, Nathan R.
    Rajendran, Kishore
    Fletcher, Joel G.
    McCollough, Cynthia H.
    Leng, Shuai
    JOURNAL OF MEDICAL IMAGING, 2021, 8 (05)
  • [9] Quality evaluation of monoenergetic images generated by dual-energy computed tomography for radiotherapy: A phantom study
    Pawalowski, Bartosz
    Szweda, Hubert
    Dudkowiak, Alina
    Piotrowski, Tomasz
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 63 : 48 - 55
  • [10] Image Quality on Dual-energy CTPA Virtual Monoenergetic Images: Quantitative and Qualitative Assessment
    Dane, Bari
    Patel, Hersh
    O'Donnell, Thomas
    Girvin, Francis
    Brusca-Augello, Geraldine
    Alpert, Jeffrey B.
    Niu, Bowen
    Attia, Mariam
    Babb, James
    Ko, Jane P.
    ACADEMIC RADIOLOGY, 2018, 25 (08) : 1075 - 1086