Single-time-point estimation of absorbed doses in PRRT using a non-linear mixed-effects model

被引:11
|
作者
Hardiansyah, Deni [1 ]
Riana, Ade [1 ]
Beer, Ambros J. [2 ]
Glatting, Gerhard [2 ,3 ,4 ]
机构
[1] Univ Indonesia, Fac Math & Nat Sci, Phys Dept, Med Phys & Biophys, Depok, Indonesia
[2] Ulm Univ, Dept Nucl Med, Ulm, Germany
[3] Ulm Univ, Dept Nucl Med, Med Radiat Phys, Ulm, Germany
[4] Klin Nuklearmed Med Strahlenphys, Albert Einstein Allee 23, D-89081 Ulm, Germany
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2023年 / 33卷 / 01期
关键词
NLME; PBPK; PRRT; Single-time Point Imaging Dosimetry; HUMAN PHARMACOKINETICS; DOSIMETRY; RADIOIMMUNOTHERAPY; PREDICTIONS; SOFTWARE;
D O I
10.1016/j.zemedi.2022.06.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Estimation of accurate time-integrated activity coefficients (TIACs) and radiation absorbed doses (ADs) is desirable for treatment planning in peptide-receptor radionuclide therapy (PRRT). This study aimed to investigate the accuracy of a simplified dosimetry using a physiologically-based pharmacokinetic (PBPK) model, a nonlinear mixed effect (NLME) model, and single-time-point imaging to calculate the TIACs and ADs of Y-90-DOTATATE in various organs of dosimetric interest and tumors. Materials & Methods: Biokinetic data of In-111-DOTATATE in tumors, kidneys, liver, spleen, and whole body were obtained from eight patients using planar scintigraphic imaging at T1 = (2.9 +/- 0.6), T2 = (4.6 +/- 0.4), T3 = (22.8 +/- 1.6), T4 = (46.7 +/- 1.7) and T5 = (70.9 +/- 1.0) h post injection. Serum activity concentration was measured at 5 and 15 min; 0.5, 1, 2, and 4 h; and 1, 2, and 3 d p.i.. A published PBPK model for PRRT, NLME, and a single-time-point imaging datum at different time points were used to calculate TIACs in tumors, kidneys, liver, spleen, whole body, and serum. Relative deviations (RDs) (median [min, max]) between the calculated TIACs from single-time-point imaging were compared to the TIACs calculated from the all-time-points fit. The root mean square error (RMSE) of the difference between the computed ADs from the single-time-point imaging and reference ADs from the all-time point fittings were analyzed. A joint root mean square error RMSEjoint of the ADs was calculated with the RSME from both the tumor and kidneys to sort the time points concerning accurate results for the kidneys and tumor dosimetry. The calculations of TIACs and ADs from the single-time-point dosimetry were repeated using the sum of exponentials (SOE) approach introduced in the literature. The RDs and the RSME of the PBPK approach in our study were compared to the SOE approach. Results: Using the PBPK and NLME models and the biokinetic measurements resulted in a good fit based on visual inspection of the fitted curves and the coefficient of variation CV of the fitted parameters (<50%). T4 was identified being the time point with a relatively low median and range of TIACs RDs, i.e., 5 [1, 21]% and 2 [-15, 21]% for kidneys and tumors, respectively. T4 was found to be the time point with the lowest joint root mean square error RMSEjoint of the ADs. Based on the RD and RMSE, our results show a similar performance as the SOE and NLME model approach. Summary: In this study, we introduced a simplified calculation of TIACs/ADs using a PBPK model, an NLME model, and a single-time-point measurement. Our results suggest a single measurement might be used to calculate TIACs/ADs in the kidneys and tumors during PRRT.
引用
收藏
页码:70 / 81
页数:12
相关论文
共 50 条
  • [31] Bayesian high-dimensional covariate selection in non-linear mixed-effects models using the SAEM algorithm
    Marion Naveau
    Guillaume Kon Kam King
    Renaud Rincent
    Laure Sansonnet
    Maud Delattre
    Statistics and Computing, 2024, 34
  • [32] Optimal Model Averaging Estimation for Generalized Linear Models and Generalized Linear Mixed-Effects Models
    Zhang, Xinyu
    Yu, Dalei
    Zou, Guohua
    Liang, Hua
    JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 2016, 111 (516) : 1775 - 1790
  • [33] Bayesian high-dimensional covariate selection in non-linear mixed-effects models using the SAEM algorithm
    Naveau, Marion
    King, Guillaume Kon Kam
    Rincent, Renaud
    Sansonnet, Laure
    Delattre, Maud
    STATISTICS AND COMPUTING, 2024, 34 (01)
  • [34] Estimation of daily soil CO2 flux using a single-time-point measurement
    Wang, H.
    McConkey, B.
    Curtin, D.
    Cutforth, H.
    CANADIAN JOURNAL OF SOIL SCIENCE, 2010, 90 (03) : 517 - 522
  • [35] Validation of a single time-point estimates of 177Lu-PRRT absorbed doses and impact on patient management for 192 therapies
    Chicheportiche, A.
    Krausz, Y.
    Godefroy, J.
    Gross, D. J.
    Grozinsky-Glasberg, S.
    Ben-Haim, S.
    JOURNAL OF NEUROENDOCRINOLOGY, 2023, 35 : 180 - 180
  • [36] Determination of mathematical model through a model selection for accurate kidney dosimetry of 177Lu-PSMA-617 using a non-linear mixed-effects model
    Hardiansyah, Deni
    Yousefzadeh-Nowshahr, Elham
    Kind, Felix
    Beer, Ambros
    Ruf, Juri
    Glatting, Gerhard
    Mix, Michael
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [37] Identification of significant host factors for HIV dynamics modelled by non-linear mixed-effects models
    Wu, HL
    Wu, L
    STATISTICS IN MEDICINE, 2002, 21 (05) : 753 - 771
  • [38] The study of long-term HIV dynamics using semi-parametric non-linear mixed-effects models
    Wu, HL
    Zhang, JT
    STATISTICS IN MEDICINE, 2002, 21 (23) : 3655 - 3675
  • [39] Single-time-point dosimetry using model selection and the Bayesian fitting method: A proof of concept
    Patrianesha, Bisma B.
    Peters, Steffie M. B.
    Hardiansyah, Deni
    Ritawidya, Rien
    Prive, Bastiaan M.
    Nagarajah, James
    Konijnenberg, Mark W.
    Glatting, Gerhard
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2025, 129
  • [40] Analysis of Field Test Data using Robust Linear Mixed-Effects Model
    Hong, Eun Hee
    Lee, Youngjo
    Ok, You Jin
    Na, Myung Hwan
    Noh, Maengseok
    Ha, Il Do
    KOREAN JOURNAL OF APPLIED STATISTICS, 2015, 28 (02) : 361 - 369