Accuracy (trueness and precision) of four tablet-based applications for three-dimensional facial scanning: An in-vitro study

被引:8
作者
Kuhlman, Deise Caldas [1 ]
Almuzian, Mohammed [2 ]
Coppini, Christianne [1 ]
Alzoubi, Emad Eddin [1 ]
机构
[1] Univ Malta, Fac Dent Surg, Med Sch, Dept Child Dent Hlth & Orthodont, MSD-2080 Msida, Malta
[2] Univ Edinburgh, ASMD Coll, Edinburgh Med Sch, Dept Orthodont, Lauriston Bldg, Lauriston Pl, Edinburgh EH3 9HA, Scotland
关键词
Imaging; Structured light scanning; Face analysis; Accuracy; Precision; Three-dimensional; SYSTEM; PHOTOGRAMMETRY; VALIDATION; REPRODUCIBILITY; RELIABILITY; SURGERY;
D O I
10.1016/j.jdent.2023.104533
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study aimed to investigate the overall and regional accuracy (trueness and precision) of digital three-dimensional (3D) facial scans obtained from four tablet-based applications, which were (Bellus) the Bellus Dental Pro & REG; (Bellus3D, Inc. Campbell, CA, USA), (Capture) the Capture & REG;: 3D Scan Anything (Standard Cyborg, Inc. San Francisco, CA, USA), (Heges) the Heges & REG; (by Marek Simonik, Ostrava, North Moravia, Czech Republic), and (Scandy) the Scandy Pro 3D Scanner & REG; (Scandy LLC, New Orleans, LA, USA). Methods: A mannequin's face was marked with 63 landmarks. Subsequently, it was scanned 5 times using each scan application on an iPad Pro & REG; (Apple Inc., Cupertino, CA, USA). The digital measurements were obtained with MeshLab & REG; (CNR-ISTI, Pisa, Tuscany, Italy) and compared to the manual measurements using a digital vernier calliper (Truper Herramientas S.A., Colonia Granada, Mexico City, Mexico). The absolute mean differ-ence and the standard deviation of the dimensional discrepancies were calculated. Moreover, the data were analysed by using one-way ANOVA, Levene's test, and Bonferroni & PRIME;s correction. Results: The absolute mean trueness values were Bellus 0.41 & PLUSMN; 0.35 mm, Capture 0.38 & PLUSMN; 0.37 mm, Heges 0.39 & PLUSMN; 0.38 mm, and Scandy 0.47 & PLUSMN; 0.44 mm. Moreover, precision values were Bellus 0.46 mm, Capture 0.46 mm, Heges 0.54 mm, and Scandy 0.64 mm. Comparing the regions, Capture and Scandy showed the highest absolute mean difference, which was 0.81 mm in the Frontal and Zygomaticofacial regions, respectively. Conclusions: The trueness and precision of all four tablet-based applications were clinically acceptable for diagnosis and treatment planning. Clinical significance: The future of the three-dimensional facial scan is auspicious, and it has the potential to be affordable, accurate, and of great value for clinicians in their daily practice.
引用
收藏
页数:12
相关论文
共 42 条
  • [31] Extra-Oral Three-Dimensional (3D) Scanning Evaluation of Three Different Impression Materials-An In Vitro Study
    Bud, Eugen S.
    Bocanet, Vlad, I
    Muntean, Mircea H.
    Vlasa, Alexandru
    Pacurar, Mariana
    Zetu, Irina Nicoleta
    Soporan, Bianca, I
    Bud, Anamaria
    [J]. POLYMERS, 2022, 14 (17)
  • [32] Validity and intraobserver reliability of three-dimensional scanning compared with conventional anthropometry for children and adolescents from a population-based cohort study
    Glock, Fabian
    Vogel, Mandy
    Naumann, Stephanie
    Kuehnapfel, Andreas
    Scholz, Markus
    Hiemisch, Andreas
    Kirsten, Toralf
    Rieger, Kristin
    Koerner, Antje
    Loeffler, Markus
    Kiess, Wieland
    [J]. PEDIATRIC RESEARCH, 2017, 81 (05) : 736 - 744
  • [33] Three-Dimensional Virtual Model for Robot-Assisted Partial Nephrectomy (RAPN) : Development of Study Protocol for Evaluation of the Learning Curve to Optimize the Precision and Accuracy of the 3D Imaging
    Traverso, Paolo
    Mantica, Guglielmo
    Giasotto, Veronica
    Terrone, Carlo
    [J]. RESEARCH AND REPORTS IN UROLOGY, 2025, 17 : 27 - 30
  • [34] Three-Dimensional SIP Design of the Four-Channel RF Transceiver Based on Silicon and ALN for X-Band Radar Applications
    Lu, Xilong
    Zhou, Shigang
    Wei, Bin
    Zhou, Liguo
    [J]. IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY, 2023, 13 (07): : 1030 - 1044
  • [35] Three-dimensional evaluation of the transfer accuracy of a bracket jig fabricated using computer-aided design and manufacturing to the anterior dentition: An in vitro study
    Park, Jae-Hyun
    Choi, Jin-Young
    Kim, Seong-Hun
    Kim, Su-Jung
    Lee, Kee-Joon
    Nelson, Gerald
    [J]. KOREAN JOURNAL OF ORTHODONTICS, 2021, 51 (06) : 375 - 386
  • [36] Three-Dimensional (3D) Stereolithographic Tooth Replicas Accuracy Evaluation: In Vitro Pilot Study for Dental Auto-Transplant Surgical Procedures
    Mastrangelo, Filiberto
    Battaglia, Rossella
    Natale, Dario
    Quaresima, Raimondo
    [J]. MATERIALS, 2022, 15 (07)
  • [37] Accuracy Assessment of Three-Dimensional Surface Imaging-Based Distance Measurements of the Face Comparison of a Handheld Facial Scanner and a Stationary Whole-Body Surface Imaging Device
    Koban, Konstantin Christoph
    Xu, Ya
    Moellhoff, Nicholas
    Ehrl, Denis
    Alfertshofer, Michael G.
    Cotofana, Sebastian
    Giunta, Riccardo E.
    Woodward, Julie
    Voropai, Daria
    Frank, Konstantin
    [J]. FACIAL PLASTIC SURGERY CLINICS OF NORTH AMERICA, 2022, 30 (02) : 159 - 166
  • [38] Proposal and Validation of a New Nonradiological Method for Postoperative Three-Dimensional Implant Position Analysis Based on the Dynamic Navigation System: An In Vitro Study
    Ma, Feifei
    Liu, Mingyue
    Liu, Xiaoqiang
    Wei, Tai
    Liu, Lilan
    Sun, Feng
    [J]. JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (02):
  • [39] Three-dimensional corrective osteotomy using a patient-specific osteotomy guide and bone plate based on a computer simulation system: accuracy analysis in a cadaver study
    Omori, Shinsuke
    Murase, Tsuyoshi
    Kataoka, Toshiyuki
    Kawanishi, Yohei
    Oura, Keiichiro
    Miyake, Junichi
    Tanaka, Hiroyuki
    Yoshikawa, Hideki
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2014, 10 (02) : 196 - 202
  • [40] Bone age assessment based on three-dimensional ultrasound and artificial intelligence compared with paediatrician-read radiographic bone age: protocol for a prospective, diagnostic accuracy study
    Chen, Li
    Zeng, Bolun
    Shen, Jian
    Xu, Jiangchang
    Cai, Zehang
    Su, Shudian
    Chen, Jie
    Cai, Xiaojun
    Ying, Tao
    Hu, Bing
    Wu, Min
    Chen, Xiaojun
    Zheng, Yuanyi
    [J]. BMJ OPEN, 2024, 14 (02):