Accuracy (trueness and precision) of four tablet-based applications for three-dimensional facial scanning: An in-vitro study

被引:13
作者
Kuhlman, Deise Caldas [1 ]
Almuzian, Mohammed [2 ]
Coppini, Christianne [1 ]
Alzoubi, Emad Eddin [1 ]
机构
[1] Univ Malta, Fac Dent Surg, Med Sch, Dept Child Dent Hlth & Orthodont, MSD-2080 Msida, Malta
[2] Univ Edinburgh, ASMD Coll, Edinburgh Med Sch, Dept Orthodont, Lauriston Bldg, Lauriston Pl, Edinburgh EH3 9HA, Scotland
关键词
Imaging; Structured light scanning; Face analysis; Accuracy; Precision; Three-dimensional; SYSTEM; PHOTOGRAMMETRY; VALIDATION; REPRODUCIBILITY; RELIABILITY; SURGERY;
D O I
10.1016/j.jdent.2023.104533
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study aimed to investigate the overall and regional accuracy (trueness and precision) of digital three-dimensional (3D) facial scans obtained from four tablet-based applications, which were (Bellus) the Bellus Dental Pro & REG; (Bellus3D, Inc. Campbell, CA, USA), (Capture) the Capture & REG;: 3D Scan Anything (Standard Cyborg, Inc. San Francisco, CA, USA), (Heges) the Heges & REG; (by Marek Simonik, Ostrava, North Moravia, Czech Republic), and (Scandy) the Scandy Pro 3D Scanner & REG; (Scandy LLC, New Orleans, LA, USA). Methods: A mannequin's face was marked with 63 landmarks. Subsequently, it was scanned 5 times using each scan application on an iPad Pro & REG; (Apple Inc., Cupertino, CA, USA). The digital measurements were obtained with MeshLab & REG; (CNR-ISTI, Pisa, Tuscany, Italy) and compared to the manual measurements using a digital vernier calliper (Truper Herramientas S.A., Colonia Granada, Mexico City, Mexico). The absolute mean differ-ence and the standard deviation of the dimensional discrepancies were calculated. Moreover, the data were analysed by using one-way ANOVA, Levene's test, and Bonferroni & PRIME;s correction. Results: The absolute mean trueness values were Bellus 0.41 & PLUSMN; 0.35 mm, Capture 0.38 & PLUSMN; 0.37 mm, Heges 0.39 & PLUSMN; 0.38 mm, and Scandy 0.47 & PLUSMN; 0.44 mm. Moreover, precision values were Bellus 0.46 mm, Capture 0.46 mm, Heges 0.54 mm, and Scandy 0.64 mm. Comparing the regions, Capture and Scandy showed the highest absolute mean difference, which was 0.81 mm in the Frontal and Zygomaticofacial regions, respectively. Conclusions: The trueness and precision of all four tablet-based applications were clinically acceptable for diagnosis and treatment planning. Clinical significance: The future of the three-dimensional facial scan is auspicious, and it has the potential to be affordable, accurate, and of great value for clinicians in their daily practice.
引用
收藏
页数:12
相关论文
共 45 条
[1]   Precision and error of three-dimensional phenotypic measures acquired from 3dMD photogrammetric images [J].
Aldridge, K ;
Boyadjiev, SA ;
Capone, GT ;
DeLeon, VB ;
Richtsmeier, JT .
AMERICAN JOURNAL OF MEDICAL GENETICS PART A, 2005, 138A (03) :247-253
[2]   Three-axis measurements with a novel system for 3D plantar foot scanning: iPhone X [J].
Alfaro-Santafe, Javier ;
Gomez-Bernal, Antonio ;
Lanuza-Cerzocimo, Carla ;
Victor Alfaro-Santafe, Jose ;
Perez-Morcillo, Aitor ;
Jesus Almenar-Arasanz, Alejandro .
FOOTWEAR SCIENCE, 2020, 12 (02) :123-131
[3]   The Accuracy of Digital Face Scans Obtained from 3D Scanners: An In Vitro Study [J].
Amornvit, Pokpong ;
Sanohkan, Sasiwimol .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (24)
[4]   EVALUATION OF THE LASER SCANNER AS A SURFACE MEASURING TOOL AND ITS ACCURACY COMPARED WITH DIRECT FACIAL ANTHROPOMETRIC MEASUREMENTS [J].
AUNG, SC ;
NGIM, RCK ;
LEE, ST .
BRITISH JOURNAL OF PLASTIC SURGERY, 1995, 48 (08) :551-558
[5]   Comparison of low cost 3D structured light scanners for face modeling [J].
Bakirman, Tolga ;
Gumusay, Mustafa Umit ;
Reis, Hatice Catal ;
Selbesoglu, Mahmut Oguz ;
Yosmaoglu, Serra ;
Yaras, Mehmet Cem ;
Seker, Dursun Zafer ;
Bayram, Bulent .
APPLIED OPTICS, 2017, 56 (04) :985-992
[6]   Fast, accurate, small-scale 3D scene capture using a low-cost depth sensor [J].
Carey, Nicole ;
Werfel, Justin ;
Nagpal, Radhika .
2017 IEEE WINTER CONFERENCE ON APPLICATIONS OF COMPUTER VISION (WACV 2017), 2017, :1268-1276
[7]   Frontal soft tissue analysis using a 3 dimensional camera following two-jaw rotational orthognathic surgery in skeletal class III patients [J].
Choi, Jong Woo ;
Lee, Jang Yeol ;
Oh, Tae-Suk ;
Kwon, Soon Man ;
Yang, Sung Joon ;
Koh, Kyung Suk .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2014, 42 (03) :220-226
[8]   Craniofacial applications of three-dimensional laser surface scanning [J].
Da Silveira, AC ;
Daw, JL ;
Kusnoto, B ;
Evans, C ;
Cohen, M .
JOURNAL OF CRANIOFACIAL SURGERY, 2003, 14 (04) :449-456
[9]   Three-dimensional methodology for photogrammetric acquisition of the soft tissues of the face: A new clinical-instrumental protocol [J].
Deli R. ;
Galantucci L.M. ;
Laino A. ;
D'Alessio R. ;
Di Gioia E. ;
Savastano C. ;
Lavecchia F. ;
Percoco G. .
Progress in Orthodontics, 14 (1)
[10]   Automated Landmark Extraction for Orthodontic Measurement of Faces Using the 3-Camera Photogrammetry Methodology [J].
Deli, Roberto ;
Di Gioia, Eliana ;
Galantucci, Luigi Maria ;
Percoco, Gianluca .
JOURNAL OF CRANIOFACIAL SURGERY, 2010, 21 (01) :87-93