Accuracy (trueness and precision) of four tablet-based applications for three-dimensional facial scanning: An in-vitro study

被引:8
|
作者
Kuhlman, Deise Caldas [1 ]
Almuzian, Mohammed [2 ]
Coppini, Christianne [1 ]
Alzoubi, Emad Eddin [1 ]
机构
[1] Univ Malta, Fac Dent Surg, Med Sch, Dept Child Dent Hlth & Orthodont, MSD-2080 Msida, Malta
[2] Univ Edinburgh, ASMD Coll, Edinburgh Med Sch, Dept Orthodont, Lauriston Bldg, Lauriston Pl, Edinburgh EH3 9HA, Scotland
关键词
Imaging; Structured light scanning; Face analysis; Accuracy; Precision; Three-dimensional; SYSTEM; PHOTOGRAMMETRY; VALIDATION; REPRODUCIBILITY; RELIABILITY; SURGERY;
D O I
10.1016/j.jdent.2023.104533
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study aimed to investigate the overall and regional accuracy (trueness and precision) of digital three-dimensional (3D) facial scans obtained from four tablet-based applications, which were (Bellus) the Bellus Dental Pro & REG; (Bellus3D, Inc. Campbell, CA, USA), (Capture) the Capture & REG;: 3D Scan Anything (Standard Cyborg, Inc. San Francisco, CA, USA), (Heges) the Heges & REG; (by Marek Simonik, Ostrava, North Moravia, Czech Republic), and (Scandy) the Scandy Pro 3D Scanner & REG; (Scandy LLC, New Orleans, LA, USA). Methods: A mannequin's face was marked with 63 landmarks. Subsequently, it was scanned 5 times using each scan application on an iPad Pro & REG; (Apple Inc., Cupertino, CA, USA). The digital measurements were obtained with MeshLab & REG; (CNR-ISTI, Pisa, Tuscany, Italy) and compared to the manual measurements using a digital vernier calliper (Truper Herramientas S.A., Colonia Granada, Mexico City, Mexico). The absolute mean differ-ence and the standard deviation of the dimensional discrepancies were calculated. Moreover, the data were analysed by using one-way ANOVA, Levene's test, and Bonferroni & PRIME;s correction. Results: The absolute mean trueness values were Bellus 0.41 & PLUSMN; 0.35 mm, Capture 0.38 & PLUSMN; 0.37 mm, Heges 0.39 & PLUSMN; 0.38 mm, and Scandy 0.47 & PLUSMN; 0.44 mm. Moreover, precision values were Bellus 0.46 mm, Capture 0.46 mm, Heges 0.54 mm, and Scandy 0.64 mm. Comparing the regions, Capture and Scandy showed the highest absolute mean difference, which was 0.81 mm in the Frontal and Zygomaticofacial regions, respectively. Conclusions: The trueness and precision of all four tablet-based applications were clinically acceptable for diagnosis and treatment planning. Clinical significance: The future of the three-dimensional facial scan is auspicious, and it has the potential to be affordable, accurate, and of great value for clinicians in their daily practice.
引用
收藏
页数:12
相关论文
共 42 条
  • [1] Trueness of One Stationary and Two Mobile Systems for Three-Dimensional Facial Scanning
    Wang, Can
    Shi, Yi-Fei
    Xiong, Qian
    Xie, Pei-Jin
    Wu, Jun-Hua
    Liu, Wei-Cai
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2022, 35 (03) : 350 - 356
  • [2] Accuracy of Smartphone-Based Three-Dimensional Facial Scanning System: A Systematic Review
    Luo, Yuna
    Zhao, Minghao
    Lu, Jianjian
    AESTHETIC PLASTIC SURGERY, 2024, 48 (21) : 4500 - 4512
  • [3] Three-Dimensional Facial Scanning at the Fingertips of Patients and Surgeons: Accuracy and Precision Testing of iPhone X Three-Dimensional Scanner
    Rudy, Hayeem L.
    Wake, Nicole
    Yee, Judy
    Garfein, Evan S.
    Tepper, Oren M.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2020, 146 (06) : 1407 - 1417
  • [4] Validation of a three-dimensional facial scanning system based on structured light techniques
    Ma, Lili
    Xu, Tianmin
    Lin, Jiuxiang
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2009, 94 (03) : 290 - 298
  • [5] Evaluation of the accuracy of a mobile and a stationary system for three-dimensional facial scanning
    Modabber, Ali
    Peters, Florian
    Kniha, Kristian
    Goloborodko, Evgeny
    Ghassemi, Alireza
    Lethaus, Bernd
    Hoelzle, Frank
    Moehlhenrich, Stephan Christian
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2016, 44 (10) : 1719 - 1724
  • [6] Three-Dimensional Static Articulation Accuracy of Virtual Models - Part I: System Trueness and Precision
    Yee, Sophia Hui Xin
    Esguerra, Roxanna Jean
    Chew, Amelia Anya Qin'An
    Wong, Keng Mun
    Tan, Keson Beng Choon
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (02): : 129 - 136
  • [7] Accuracy (trueness and precision) of 3-dimensional virtual patients: An in vitro investigation of different facial scanners and digital integration techniques
    Yang, Shengtao
    Revilla-Leon, Marta
    Wei, Chenxuan
    Yuan, Quan
    Yue, Li
    Li, Junying
    JOURNAL OF DENTISTRY, 2025, 154
  • [8] Reliability of a three-dimensional facial camera for dental and medical applications: A pilot study
    Liu, Shiming
    Srinivasan, Murali
    Moerzinger, Roland
    Lancelle, Marcel
    Beeler, Thabo
    Gross, Markus
    Solenthaler, Barbara
    Fehmer, Vincent
    Sailer, Irena
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (03) : 282 - 287
  • [9] Accuracy and precision of polyurethane dental arch models fabricated using a three-dimensional subtractive rapid prototyping method with an intraoral scanning technique
    Kim, Jae-Hong
    Kim, Ki-Baek
    Kim, Woong-Chul
    Kim, Ji-Hwan
    Kim, Hae-Young
    KOREAN JOURNAL OF ORTHODONTICS, 2014, 44 (02) : 69 - 76
  • [10] Feasibility and Accuracy of Noncontact Three-Dimensional Digitizers for Geometric Facial Defects: An In Vitro Comparison
    Aswehlee, Amel M.
    Elbashti, Mahmoud E.
    Hattori, Mariko
    Sumita, Yuka I.
    Taniguchi, Hisashi
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2018, 31 (06) : 601 - 606