3D Digital Modeling of Dental Casts from Their 3D CT Images with Scatter and Beam-Hardening Correction

被引:0
作者
Hegazy, Mohamed A. A. [1 ]
Cho, Myung Hye [1 ]
Cho, Min Hyoung [2 ]
Lee, Soo Yeol [2 ]
机构
[1] Ray, R&D Ctr, Seongnam 13494, South Korea
[2] Kyung Hee Univ, Dept Biomed Engn, Yongin 17104, South Korea
关键词
dental 3D modeling; CBCT; dental casts; scatter artifacts; beam-hardening artifacts; X-RAY SCATTER; COMPUTED-TOMOGRAPHY; ALGORITHM; RADIATION;
D O I
10.3390/s24061995
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Dental 3D modeling plays a pivotal role in digital dentistry, offering precise tools for treatment planning, implant placement, and prosthesis customization. Traditional methods rely on physical plaster casts, which pose challenges in storage, accessibility, and accuracy, fueling interest in digitization using 3D computed tomography (CT) imaging. We introduce a method that can reduce both artifacts simultaneously. To validate the proposed method, we carried out CT scan experiments using plaster dental casts created from dental impressions. After the artifact correction, the CT image quality was greatly improved in terms of image uniformity, contrast-to-noise ratio (CNR), and edge sharpness. We examined the correction effects on the accuracy of the 3D models generated from the CT images. As referenced to the 3D models derived from the optical scan data, the root mean square (RMS) errors were reduced by 8.8 similar to 71.7% for three dental casts of different sizes and shapes. Our method offers a solution to challenges posed by artifacts in CT scanning of plaster dental casts, leading to enhanced 3D model accuracy. This advancement holds promise for dental professionals seeking precise digital modeling for diverse applications in dentistry.
引用
收藏
页数:14
相关论文
共 39 条
  • [1] A quantitative CBCT pipeline based on 2D antiscatter grid and grid-based scatter sampling for image-guided radiation therapy
    Bayat, Farhang
    Ruan, Dan
    Miften, Moyed
    Altunbas, Cem
    [J]. MEDICAL PHYSICS, 2023, 50 (12) : 7980 - 7995
  • [2] Scattering correction using continuously thickness-adapted kernels
    Bhatia, Navnina
    Tisseur, David
    Buyens, Fanny
    Letang, Jean Michel
    [J]. NDT & E INTERNATIONAL, 2016, 78 : 52 - 60
  • [3] AN ANALYTICAL MODEL OF THE SCATTERED RADIATION DISTRIBUTION IN DIAGNOSTIC-RADIOLOGY
    BOONE, JM
    SEIBERT, JA
    [J]. MEDICAL PHYSICS, 1988, 15 (05) : 721 - 725
  • [4] Efficient scatter distribution estimation and correction in CBCT using concurrent Monte Carlo fitting
    Bootsma, G. J.
    Verhaegen, F.
    Jaffray, D. A.
    [J]. MEDICAL PHYSICS, 2015, 42 (01) : 54 - 68
  • [5] Cone-Beam Angle Dependency of 3D Models Computed from Cone-Beam CT Images
    Cho, Myung Hye
    Hegazy, Mohamed A. A.
    Cho, Min Hyoung
    Lee, Soo Yeol
    [J]. SENSORS, 2022, 22 (03)
  • [6] A motion artifact reduction method for dental CT based on subpixel-resolution image registration of projection data
    Eldib, Mohamed Elsayed
    Hegazy, Mohamed A. A.
    Cho, Myung Hye
    Cho, Min Hyoung
    Lee, Soo Yeol
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2018, 103 : 232 - 243
  • [7] CAD-based x-ray CT calibration and error compensation
    Fragnaud, Cedric
    Remacha, Clement
    Betancur, Julian
    Roux, Stephane
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2022, 33 (06)
  • [8] Diagnostic Accuracy of Cone Beam Computed Tomography for Dimensional Linear Measurements in the Mandible
    Halperin-Sternfeld, Michal
    Machtei, Eli E.
    Horwitz, Jacob
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (03) : 593 - 599
  • [9] Extraction of primary signal from EPIDs using only forward convolution
    Hansen, VN
    Swindell, W
    Evans, PM
    [J]. MEDICAL PHYSICS, 1997, 24 (09) : 1477 - 1484
  • [10] Metal Artifact Reduction in Dental CBCT Images Using Direct Sinogram Correction Combined with Metal Path-Length Weighting
    Hegazy, Mohamed A. A.
    Cho, Myung Hye
    Cho, Min Hyoung
    Lee, Soo Yeol
    [J]. SENSORS, 2023, 23 (03)