Multi-echo single-shot spectroscopy combined with simultaneous 2D model fitting for fast and accurate measurement of metabolite-specific concentrations and T2 relaxation times

被引:3
作者
Rizzo, Rudy [1 ,2 ,3 ,4 ]
Kreis, Roland [1 ,2 ,3 ,5 ]
机构
[1] Univ Bern, Dept Diagnost & Intervent Neuroradiol, MR Methodol, Bern, Switzerland
[2] Univ Bern, Dept Biomed Res, Bern, Switzerland
[3] Swiss Inst Translat & Entrepreneurial Med Sitem In, Translat Imaging Ctr TIC, Bern, Switzerland
[4] Univ Bern, Grad Sch Cellular & Biomed Sci, Bern, Switzerland
[5] Univ Bern, MR Methodol, Freiburgstr 3, CH-3010 Bern, Switzerland
基金
瑞士国家科学基金会;
关键词
brain; CPMG; estimation; in vivo; metabolite concentrations; modeling; multiparametric MR; transverse (T-2) relaxation times; MAGNETIC-RESONANCE-SPECTROSCOPY; MACROMOLECULE BASE-LINE; HUMAN VISUAL-CORTEX; HUMAN BRAIN; IN-VIVO; H-1-NMR SPECTROSCOPY; NEUROCHEMICAL PROFILES; MR SPECTROSCOPY; ACQUISITION; 3T;
D O I
10.1002/nbm.5016
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The purpose of the current study was to develop a novel single-voxel MR spectroscopy acquisition scheme to simultaneously determine metabolite-specific concentrations and transverse relaxation times within realistic clinical scan times. Partly truncated multi-TE data are acquired as an echo train in a single acquisition (multi-echo single-shot [MESS]). A 2D multiparametric model fitting approach combines truncated, low-resolved short TE data with fully sampled, highly resolved, longer TE data to yield concentration and T-2 estimates for major brain metabolites simultaneously. Cramer-Rao lower bounds (CRLB) are used as a measure of performance. The novel scheme was compared with traditional multi-echo multi-shot methods. In silico, in vitro, and in vivo experiments support the findings. MESS schemes, requiring only 2 min 12 s for the acquisition of three echo times, provide valid concentration and relaxation estimates for multiple metabolites and outperform traditional methods for simultaneous determinations of metabolite-specific T(2)s and concentrations, with improvements ranging from 5% to 30% for T(2)s and from 10% to 50% for concentrations. However, substantial unsuppressed residual water signals may hamper the method's reproducibility, as observed in an initial experiment setup that prioritizes short TEs with severely truncated acquisition for the benefit of signal-to-noise ratio (SNR). Nevertheless, CRLB have been confirmed to be well suited as design criteria, and within-session repeatability approaches CRLB when residual water is removed in postprocessing by exploiting longer and less truncated data recordings. MESS MRS combined with 2D model fitting promises comparable accuracy, increased precision, or inversely shorter experimental times compared with traditional approaches. However, the optimal design must be investigated as a trade-off between SNR, the truncation factor, and TE batch selections, all of which influence the robustness of estimations.
引用
收藏
页数:20
相关论文
共 57 条
  • [1] Simultaneous determination of metabolite concentrations, T1 and T2 relaxation times
    An, Li
    Li, Shizhe
    Shen, Jun
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (06) : 2072 - 2081
  • [2] Beracha I., BIORXIV, DOI [10.1101/2022.03.16.484410, DOI 10.1101/2022.03.16.484410]
  • [3] On the use of Cramer-Rao minimum variance bounds for the design of magnetic resonance spectroscopy experiments
    Bolliger, Christine S.
    Boesch, Chris
    Kreis, Roland
    [J]. NEUROIMAGE, 2013, 83 : 1031 - 1040
  • [4] Optimal acquisition schemes for in vivo quantitative magnetization transfer MRI
    Cercignani, Mara
    Alexander, Daniel C.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (04) : 803 - 810
  • [5] Two-dimensional linear-combination model fitting of magnetic resonance spectra to define the macromolecule baseline using FiTAID, a Fitting Tool for Arrays of Interrelated Datasets
    Chong, Daniel G. Q.
    Kreis, Roland
    Bolliger, Christine S.
    Boesch, Chris
    Slotboom, Johannes
    [J]. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2011, 24 (03) : 147 - 164
  • [6] An efficient approach to optimal experimental design for magnetic resonance fingerprinting with B-splines
    Crafts, Evan Scope
    Lu, Hengfa
    Ye, Huihui
    Wald, Lawrence L.
    Zhao, Bo
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (01) : 239 - 253
  • [7] Contribution of macromolecules to brain 1H MR spectra: Experts' consensus recommendations
    Cudalbu, Cristina
    Behar, Kevin L.
    Bhattacharyya, Pallab K.
    Bogner, Wolfgang
    Borbath, Tamas
    de Graaf, Robin A.
    Gruetter, Rolf
    Henning, Anke
    Juchem, Christoph
    Kreis, Roland
    Lee, Phil
    Lei, Hongxia
    Marjanska, Malgorzata
    Mekle, Ralf
    Murali-Manohar, Saipavitra
    Povazan, Michal
    Rackayova, Veronika
    Simicic, Dunja
    Slotboom, Johannes
    Soher, Brian J.
    Starcuk, Zenon, Jr.
    Starcukova, Jana
    Tkac, Ivan
    Williams, Stephen
    Wilson, Martin
    Wright, Andrew Martin
    Xin, Lijing
    Mlynarik, Vladimir
    [J]. NMR IN BIOMEDICINE, 2021, 34 (05)
  • [8] Changes in the intracellular microenvironment in the aging human brain
    Deelchand, Dinesh K.
    McCarten, J. Riley
    Hemmy, Laura S.
    Auerbach, Edward J.
    Eberly, Lynn E.
    Marjanska, Malgorzata
    [J]. NEUROBIOLOGY OF AGING, 2020, 95 : 168 - 175
  • [9] Transverse relaxation time constants of the five major metabolites in human brain measured in vivo using LASER and PRESS at 3 T
    Deelchand, Dinesh K.
    Auerbach, Edward J.
    Kobayashi, Naoharu
    Marjanska, Malgorzata
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (03) : 1260 - 1265
  • [10] Measurement of Transverse Relaxation Times of J-Toupled Metabolites in the Human Visual Cortex at 4 T
    Deelchand, Dinesh Kumar
    Henry, Pierre-Gilles
    Ugurbil, Kamil
    Marjanska, Malgorzata
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (04) : 891 - 897