Corona current and audible noise characteristics of HVDC transmission lines and their relationship at high-altitude

被引:0
|
作者
Zhao, Luxing [1 ]
Xie, Li [1 ]
Liu, Chao [2 ]
Gao, Lei [2 ]
Qu, Jia [3 ]
Zhang, Hengzhi [2 ]
Liu, Yingyi [4 ]
机构
[1] China Elect Power Res Inst Co Ltd, High Voltage Dept, Beijing, Peoples R China
[2] State Grid Tibet Elect Power Co Ltd, Elect Power Res Inst, Lhasa, Peoples R China
[3] State Grid Tibet Elect Power Co Ltd, Naqu Power Supply Co, Naqu, Peoples R China
[4] Beihang Univ, Sch Automation Sci & Elect Engn, Beijing, Peoples R China
关键词
audible noise; corona current; correlation; equivalent A-weight sound level; high-altitude; test line; DISCHARGE; CAGE;
D O I
10.1049/gtd2.12832
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The audible noise (AN) of HVDC transmission lines, as an external manifestation of the corona discharge, intensifies with the increase of altitude. In high-altitude area, the AN has been a key factor in determining the type of conductors for transmission lines. In order to study the characteristics of corona current and AN of HVDC transmission lines at high-altitude, we erected a HVDC test line at an altitude of 4300 m, and carried out AN and corona current tests under different voltages. Through the test, the basic data of AN and corona current of HVDC test line at high-altitude were obtained. Based on the corona current curve, the corona inception electric field strength of the conductor was proposed. The relationship between the equivalent A-weight sound level and the high-frequency noise component was clarified. The relational expression of the AN and corona current for the HVDC test line were suggested. The research results show that, there is a relatively fixed difference of about 7-8.3 dB between the equivalent A-weight sound level and the 8 kHz sound pressure level at altitude 4300 m, and a clear logarithmic relationship between the equivalent A-weight sound level and the average value of the corona current.
引用
收藏
页码:3399 / 3409
页数:11
相关论文
共 50 条
  • [21] Superhydrophobic and Thermally Conductive Coating for Restraining Corona Loss and Audible Noise of High-Voltage Transmission Lines
    Li, Li
    Xu, Junhuang
    Wang, Yifan
    Meng, Wei
    Fan, Shengping
    Li, Hongqiang
    COATINGS, 2023, 13 (09)
  • [22] Corona audible noise measurements in a small indoor corona cage under HVDC voltages
    Lekganyane, M. J.
    Ijumba, N. M.
    Britten, A. C.
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 2663 - +
  • [23] Audible noise analysis of 750-kV AC transmission line in high-altitude area under different weather
    Zhang, Yemao
    Xu, Jilai
    Li, Ni
    Ding, Lijian
    Wu, Xiong
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2023, 17 (11) : 2644 - 2654
  • [24] Environmental Impact Analysis and Prediction Method of Audible Noise on 750 kV Transmission Lines in High Altitude Areas
    Li, Pengfei
    Zhang, Yemao
    Lu, Yao
    Liu, Jianben
    Yin, Kaiyang
    Gaodianya Jishu/High Voltage Engineering, 2024, 50 (12): : 5648 - 5657
  • [25] Influence of Humidity on Spectrum Characteristics of Audible Noise of DC Transmission Lines
    Yi, Yong
    Chen, Zhengying
    Wang, Liming
    2016 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP), 2016, : 275 - 278
  • [26] CORONA LOSS CHARACTERISTICS OF PRACTICAL HVDC TRANSMISSION LINES .2. BIOPOLAR LINES
    SARMA, MP
    JANISCHE.W
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1971, PA90 (03): : 1055 - &
  • [27] CORONA LOSS CHARACTERISTICS OF PRACTICAL HVDC TRANSMISSION LINES .1. UNIPOLAR LINES
    SARMA, MP
    JANISCHE.W
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1970, PA89 (05): : 860 - &
  • [28] Environmental effect of high voltage AC transmission lines audible noise
    Al-Faraj, MA
    Shwehdi, MH
    Farag, AS
    IECEC-97 - PROCEEDINGS OF THE THIRTY-SECOND INTERSOCIETY ENERGY CONVERSION ENGINEERING CONFERENCE, VOLS 1-4: VOL.1: AEROSPACE POWER SYSTEMS AND TECHNOL; VOL 2: ELECTROCHEMICAL TECHNOL, CONVERSION TECHNOL, THERMAL MANAGEMENT; VOLS 3: ENERGY SYSTEMS, RENEWABLE ENERGY RESOURCES, ENVIRONMENTAL IMPACT, POLICY IMPACTS ON ENERGY; VOL 4: POST DEADLINE PAPERS, INDEX, 1997, : 2082 - 2087
  • [29] A Method for the Indirect Detection of Audible Noise From High-Voltage Direct Current Transmission Lines
    Liu, Yingyi
    Xv, Jiahuan
    Liu, Yuanqing
    Yuan, Haiwen
    Cui, Yong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (07) : 4358 - 4369
  • [30] Radio Interference of Ultra HVDC Transmission Lines in High Altitude Region
    Yu, Zhanqing
    Zeng, Rong
    Li, Min
    Li, Ruihai
    Liu, Lei
    Yang, Dawei
    Zhang, Zheng
    Zhang, Bo
    Tian, Feng
    2010 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY & TECHNICAL EXHIBITION ON EMC RF/MICROWAVE MEASUREMENTS & INSTRUMENTATION, 2010, : 1672 - 1675