Influence of cathode air supply mode on the performance of an open cathode air-cooled proton exchange membrane fuel cell stack

被引:4
|
作者
Chen, Jie [1 ]
Sun, Liangbo [1 ]
Zhu, Wenli [1 ]
Pei, Houchang [1 ]
Xing, Lu [2 ]
Tu, Zhengkai [3 ]
机构
[1] Wuhan Polytech Univ, Sch Mech Engn, Wuhan 430048, Peoples R China
[2] Northumbria Univ, Mech & Construct Engn, Newcastle Upon Tyne NE1 8ST, England
[3] Huazhong Univ Sci & Technol, Sch Energy & Power Engn, Wuhan 430074, Peoples R China
关键词
Air-cooled PEMFC stack; Temperature distribution; Cathode air intake mode; Ambient temperature; OPERATING CHARACTERISTICS; VOLTAGE UNIFORMITY; PEMFC STACK; DESIGN; SYSTEM; GAS;
D O I
10.1016/j.applthermaleng.2024.122709
中图分类号
O414.1 [热力学];
学科分类号
摘要
Open-cathode air-cooled proton exchange membrane fuel cells (PEMFCs) simplify conventional cell stacks' cooling and air supply systems, effectively reducing additional energy consumption and improving portability and reliability. As an air fan provides the cathode reaction gas, different air supply conditions significantly influence the output performance of the air-cooled PEMFC stack. This study used a cathode air supply with exhaust and blow modes to investigate the stack performance under different operating conditions. Compared with the exhaust air supply mode, the stack output voltage in the blow-flow mode increased by 5.5 %, and both voltage and temperature uniformities were improved, with 43.0 % and 23.9 % reductions in standard deviation, respectively, when the current density was 300 mA/cm2. In addition, the effect of ambient temperature on stack performance was investigated. Comparing the stack's performance at 15 degrees C and 30 degrees C ambient temperatures, the higher ambient temperature increased the stack's voltage, but led to worsening non-uniform temperature distribution. In the air-cooled PEMFC stack, the influence of the heat generated by the fan on the air-cooled stack temperature could not be ignored. The air supply in the blow-flow mode transfers heat to the stack. At a lower ambient temperature, the temperature increase in the stack was more evident under the exhaust air supply mode.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Performance improvement and numerical study on cathode channel for air-cooled open-cathode proton exchange membrane fuel cells
    Zhang, Lu
    Wu, Xiaoyu
    Deng, Zhijun
    Zhao, Chen
    ENGINEERING APPLICATIONS OF COMPUTATIONAL FLUID MECHANICS, 2024, 18 (01)
  • [2] Effects of cathode gas channel design on air-cooled proton exchange membrane fuel cell performance
    Peng, Ming
    Chen, Li
    Gong, Kunying
    Tao, Wen-quan
    APPLIED THERMAL ENGINEERING, 2024, 236
  • [3] Experimental study on the endplate effect on the cold-start performance of an open-cathode air-cooled proton exchange membrane fuel cell stack
    Chang, Huawei
    Cai, Fengyang
    Yang, Zhengbo
    Duan, Chen
    Tu, Zhengkai
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2023, 48 (40) : 15215 - 15228
  • [4] Barrel effect in an air-cooled proton exchange membrane fuel cell stack
    Yu, Xianxian
    Cai, Shanshan
    Luo, Xiaobing
    Tu, Zhengkai
    ENERGY, 2024, 286
  • [5] Novel optimal structure design and testing of air-cooled open-cathode proton exchange membrane fuel cell
    Zhao, Chen
    Li, Baozhu
    Zhang, Lu
    Han, Yaru
    Wu, Xiaoyu
    RENEWABLE ENERGY, 2023, 215
  • [6] Dynamic response study of air-cooled proton exchange membrane fuel cell stack
    Houchang Pei
    Zhangda Liu
    Jibing Chen
    Liangbo Sun
    Beihai Wang
    Lu Xing
    Shanshan Cai
    Zhengkai Tu
    Progress in Natural Science:Materials International, 2024, 34 (06) : 1318 - 1326
  • [7] Experimental study on the dynamic response of voltage and temperature of an open-cathode air-cooled proton exchange membrane fuel cell
    Guo, Ziyang
    Tian, Chenqi
    Gong, Kunying
    Xu, Weiqiang
    Chen, Li
    Tao, Wen-Quan
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 57 : 601 - 615
  • [8] Experimental Investigation on the Anode Flow Field Design for an Air-Cooled Open-Cathode Proton Exchange Membrane Fuel Cell
    Deng, Zhijun
    Li, Baozhu
    Xing, Shuang
    Zhao, Chen
    Wang, Haijiang
    MEMBRANES, 2022, 12 (11)
  • [9] Dynamic performance for a kW-grade air-cooled proton exchange membrane fuel cell stack
    Zhu, Kai-Qi
    Ding, Quan
    Xu, Jiang-Hai
    Yang, Chen
    Zhang, Jing
    Zhang, Yan
    Huang, Tai-Ming
    Wan, Zhong-Min
    Wang, Xiao-Dong
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2022, 47 (83) : 35398 - 35411
  • [10] Performance improvement for air-cooled open-cathode proton exchange membrane fuel cell with different design parameters of the gas diffusion layer
    Chen Zhao
    Shuang Xing
    Wei Liu
    Ming Chen
    Haijiang Wang
    Progress in Natural Science:Materials International, 2020, 30 (06) : 825 - 831