High-Accuracy Wave Plate Measurement Based on Dual- Frequency Laser Interferometry and Phase Detection

被引:3
作者
Chen Qianghua [1 ]
Guan Yu [1 ]
Zhou Sheng [1 ]
Ding Jinhong [1 ]
Lii Hongbo [1 ]
Sun Qiguo [1 ]
Luo Huifu [2 ]
机构
[1] North China Univ Technol, Sch Mech & Mat Engn, Beijing 100144, Peoples R China
[2] Beijing Inst Technol, Sch Mech Engn, Beijing 100081, Peoples R China
关键词
measurement; wave plate measurement; phase retardation; fast axis azimuth; dual-frequency laser interference; phase detection; FAST AXIS; RETARDATION;
D O I
10.3788/AOS221237
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Objective The accuracy of wave plates has a significant influence on the performance of polarized optical systems, and thus the high-accuracy measurement of their phase retardation and fast axis azimuths is required. Many wave plate measurement methods at present are based on the principle of light intensity measurement. The measurement accuracy is easily affected by light intensity fluctuations, and the requirements for light source and stability of light path are high. Quite a few methods among them cannot measure the fast axis azimuth of the wave plate at the same time. Therefore, many researchers have also studied other measurement methods, such as laser feedback method, to improve the performance of wave plate measurement. In this study, a high-accuracy wave plate measurement method based on dual frequency laser interferometry and phase detection is proposed. It has good advantages of wave plate measurement. Methods A dual-frequency laser heterodyne interference optical path is constructed by using a rotatable half-wave plate and a corner prism in this study (Fig. 1). The relationship between the phase retardation of the wave plate to be measured and the phase difference between the measured signal and the reference signal is obtained by Jones matrix method. During the measurement, the phase retardation and the fast axis azimuth of the measured wave plate can be obtained by rotating the half wave plate, monitoring the change of phase difference between the measured signal and the reference signal through a phase meter, and recording the maximum value and minimum value as well as the corresponding fast axis azimuth of the half wave plate. Results and Discussions Error analysis shows that the measurement uncertainty of the phase retardation is about 3.9', and that of the fast axis azimuth is about 5'' under the experimental conditions. The experimental comparison results indicate that the result of the proposed method is in good agreement with that of other methods. The repeated experiments show that the measurement standard deviation is about 2'. The measurement is not affected by the azimuth accuracy of birefringent devices such as wave plates and polarizers in principle. The common optical path structure is one of the advantages of the proposed measurement system, so the measurement is highly stable. The signal processing adopts the phase detection means which has higher accuracy than intensity detection means. In addition, the proposed method has the advantages of few components, a simple structure and a quick measurement process. Conclusions Wave plates are important optical components, whose accuracy has a significant influence on the performance of polarized optical systems. Therefore, the high-precision measurement of the phase retardation and fast axis azimuth of the wave plate is required. A high-accuracy wave plate measurement method based on dual-frequency laser interferometry and phase detection is proposed in this paper. A dual-frequency laser heterodyne interference optical path is constructed by using a rotatable half- wave plate and a corner prism. It can accurately measure the phase retardation and the fast axis azimuth of an arbitrary wave plate. The measurement is not affected by the azimuth accuracy of birefringent devices such as wave plates and polarizers in principle. The common optical path structure is one of the advantages of the measurement system, so the measurement stability is good. The signal processing adopts the phase detection means which has higher accuracy than intensity detection means. The measurement formulae are deduced and the measurement system is built. Error analysis reveals that the measurement uncertainty of the phase retardation is about 3.9', and that of the fast axis azimuth is about 5'' under the experimental conditions. The experimental comparison results indicate that the result of the proposed method is in good agreement with that of other methods. The repeated experiments demonstrate that the measurement standard deviation is about 2'. In addition, the presented method has the advantages of few components, a simple structure and a quick measurement process.
引用
收藏
页数:7
相关论文
共 22 条
[1]   Novel method for determining the fast axis and phase retardation of a wave plate using Fresnel Rhomb [J].
Bakhouche, B. ;
Beniaiche, A. ;
Guessas, H. .
JOURNAL OF MODERN OPTICS, 2017, 64 (03) :238-243
[2]   An interferometric method for simultaneously determination the phase retardation and fast-axis azimuth angle of a wave plate [J].
Chen, Kun-Huang ;
Lin, Chih-Hsiung ;
Liu, Po-Cheng .
JOURNAL OF MODERN OPTICS, 2020, 67 (11) :992-997
[3]   Alternative method for measuring the phase retardation and fast axis of a wave plate [J].
Chen, Kun-Huang ;
Tseng, Jen-Te ;
Yeh, Chien-Hung ;
Chen, Jing-Heng .
OPTICAL REVIEW, 2019, 26 (06) :652-658
[4]   Three-Dimensional Temperature Field Measurement Based on Multi-Step Phase Shift Method and Polarization Interference Optical Tomography Optical Path [J].
Chen Qianghua ;
Zhou Sheng ;
Ding Jinhong ;
Han Wenyuan ;
Kong Xiangyue ;
Luo Huifu .
ACTA OPTICA SINICA, 2022, 42 (07)
[5]   Phase retardation measurement of an arbitrary wave plate based on magneto-optical modulating and residue detecting of the base frequency component of the signal [J].
Chen, Qianghua ;
Liu, Binchao ;
He, Yongxi ;
Luo, Huifu ;
Lv, Weiwei .
OPTICS LETTERS, 2018, 43 (18) :4514-4517
[6]   Waveplate analyzer using binary magneto-optic rotators [J].
Chen, Xiaojun ;
Yan, Lianshan ;
Yao, X. Steve .
OPTICS EXPRESS, 2007, 15 (20) :12989-12994
[7]   Study of the retardance of a birefringent waveplate at tilt incidence by Mueller matrix ellipsometer [J].
Gu, Honggang ;
Chen, Xiuguo ;
Zhang, Chuanwei ;
Jiang, Hao ;
Liu, Shiyuan .
JOURNAL OF OPTICS, 2018, 20 (01)
[8]   Accurate alignment of optical axes of a biplate using a spectroscopic Mueller matrix ellipsometer [J].
Gu, Honggang ;
Chen, Xiuguo ;
Jiang, Hao ;
Zhang, Chuanwei ;
Li, Weiqi ;
Liu, Shiyuan .
APPLIED OPTICS, 2016, 55 (15) :3935-3941
[9]   Phase retardation measurement of wave plates based on the self-calibration method [J].
Hou, Junfeng ;
Yu, Jia ;
Wang, Dongguang ;
Deng, Yuanyong ;
Zhang, Zhiyong ;
Sun, Yingzi .
Zhongguo Jiguang/Chinese Journal of Lasers, 2012, 39 (04) :1
[10]  
Liang Q T, 1988, OPTICAL INSTRUMENTS, V10, P1