Development of a nucleic acid-based screen printed electrochemical biosensor using Ti3C2Tx-MXene for the detection of SARS-CoV-2

被引:8
|
作者
Bharti, Anu [1 ]
Singh, Sonam [1 ,2 ]
Munthala, Dhanunjaya [3 ]
Roy, Souradeep [1 ,4 ]
Pojprapai, Soodkhet [3 ]
Suksaweang, Sanong [5 ]
Sain, Sourav [6 ]
Roy, Susanta Sinha [6 ]
Mohamed, Julie Juliewatty [7 ]
Avasthi, Devesh Kumar [1 ]
Mathur, Ashish [1 ]
机构
[1] UPES, Ctr Interdisciplinary Res & Innovat CIDRI, Dehra Dun, India
[2] UPES, Sch Adv Engn, Dept Chem, Dehra Dun, India
[3] Suranaree Univ Technol, Sch Ceram Engn, Nakhon Ratchasima, Thailand
[4] UPES, Sch Hlth Sci & Technol, Dehra Dun, India
[5] Suranaree Univ Technol, Inst Med, Nakhon Ratchasima, Thailand
[6] Shiv Nadar Univ Inst Eminence, Sch Nat Sci, Dept Phys, Greater Noida, India
[7] Univ Malaysia Kelantan, Fac Bioengn & Technol, Dept Mat Technol, Kota Baharu, Malaysia
关键词
SARS-CoV-2; Nucleic Acid; COVID-19; Electrochemical Biosensor; Ti 3 C 2 T x -MXene; Screen Printed Carbon Electrode;
D O I
10.1016/j.microc.2023.109521
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The SARS-CoV-2 virus poses a major risk to human health which has put a tremendous strain on already stretched healthcare resources. Despite continuous improvements in Coronavirus Disease-19 (COVID-19) detection, treatment technology and ongoing global immunization efforts, the lethal virus has undergone several mutations and is still claiming millions of lives worldwide. In this respect, the development of a hybridization based nucleic acid biosensor for SARS-CoV-2 virus is the major focus of the current effort in response to the critical demand for developing quick and accurate diagnostic methods. Herein, we employ Screen Printed Carbon Electrode (SPCE) coated with Ti3C2Tx-MXene nanosheets followed by amino-functionalized probe DNA (NH2- pDNA) as a robust surface for the sensing of SARS-CoV-2. Electrochemical impedance spectroscopy, cyclic voltammetry and differential pulse voltammetry were employed for assessing the electrochemical behavior of NH2- pDNA/Ti3C2Tx/SPCE bioelectrode. Meanwhile, the analytical sensor response for SARS-CoV-2 was studied using impedance within target DNA concentration of 0.1 pM 1 mu M. The developed biosensor displayed detection limit of 0.004 pM, showing a high degree of selectivity in the presence of non-complementary interferents with a shelf life of 40 days. Additionally, a good linearity for the detection of target sequence in spiked serum samples was established; as a result, exhibiting huge potential for use in the contemporary healthcare sector for fast, accurate and reliable diagnosis of COVID-19 in a point-of-care scenario.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Sensitive Detection of SARS-CoV-2 Spike Protein Using an Aptamer Sandwich Assay-Based Electrochemical Biosensor
    Kim, Hyoung-Mi
    Park, Junghun
    BIOCHIP JOURNAL, 2024, 18 (04) : 622 - 632
  • [22] Low Dose of Ti3C2 MXene Quantum Dots Mitigate SARS-CoV-2 Infection
    Yilmazer, Acelya
    Alagarsamy, Keshav Narayan
    Gokce, Cemile
    Summak, Gokce Yagmur
    Rafieerad, Alireza
    Bayrakdar, Fatma
    Ozturk, Berfin Ilayda
    Aktuna, Suleyman
    Delogu, Lucia Gemma
    Unal, Mehmet Altay
    Dhingra, Sanjiv
    SMALL METHODS, 2023, 7 (08)
  • [23] Electrochemical Biosensor for the Detection of SARS-CoV-2 Main Protease and Its Inhibitor Ebselen
    Zhang, Qiongyu
    Liu, Gang
    Ou, Lingbin
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (04):
  • [24] Ultrasensitive SARS-CoV-2 diagnosis by CRISPR-based screen-printed carbon electrode
    Wu, Lina
    Wang, Xinjie
    Wu, Chengyuan
    Cao, Xizhong
    Tang, Taishan
    Huang, He
    Huang, Xingxu
    ANALYTICA CHIMICA ACTA, 2022, 1221
  • [25] Combined Diagnosis of SARS-CoV-2: Rapid Antigen Detection as an Adjunct to Nucleic Acid Detection
    Li, Xuewen
    Wang, Yiting
    Pan, Junqi
    Xu, Jiancheng
    Zhou, Qi
    LABORATORY MEDICINE, 2023, 54 (02) : E37 - E43
  • [26] ViPER: A visual bipolar electrochemical biosensor based on isothermal addition of a universal tag for detection of SARS-CoV-2
    Shadman, Seyedeh Malahat
    Tavakoli-Koopaei, Reyhaneh
    Mehrgardi, Masoud A.
    Javadi-Zarnaghi, Fatemeh
    BIOSENSORS & BIOELECTRONICS, 2025, 275
  • [27] Effects of Storage Temperature and Media/Buffer for SARS-CoV-2 Nucleic Acid Detection
    Kim, Namhee
    Kwon, Ahrin
    Roh, Eun Youn
    Yoon, Jong Hyun
    Han, Mi Seon
    Park, Sang-Won
    Park, Hyunwoong
    Shin, Sue
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2021, 155 (02) : 280 - 285
  • [28] Rapid, Ultrasensitive, and Quantitative Detection of SARS-CoV-2 Using Antisense Oligonucleotides Directed Electrochemical Biosensor Chip
    Alafeef, Maha
    Dighe, Ketan
    Moitra, Parikshit
    Pan, Dipanjan
    ACS NANO, 2020, 14 (12) : 17028 - 17045
  • [29] G-quadruplex based biosensor: A potential tool for SARS-CoV-2 detection
    Xi, Hui
    Juhas, Mario
    Zhang, Yang
    BIOSENSORS & BIOELECTRONICS, 2020, 167 (167)
  • [30] Portable Electrochemical Immunosensor Based on a Gold Microblobs-Optimized Screen-Printed Electrode for SARS-CoV-2 Diagnosis
    Giacomet, Melissa M.
    Buzzetti, Paulo H. M.
    Junior, Oscar O. S.
    Martins, Alessandro F.
    Bonafe, Elton G.
    Monteiro, Johny P.
    INORGANICS, 2024, 12 (09)