Development of a nucleic acid-based screen printed electrochemical biosensor using Ti3C2Tx-MXene for the detection of SARS-CoV-2

被引:8
|
作者
Bharti, Anu [1 ]
Singh, Sonam [1 ,2 ]
Munthala, Dhanunjaya [3 ]
Roy, Souradeep [1 ,4 ]
Pojprapai, Soodkhet [3 ]
Suksaweang, Sanong [5 ]
Sain, Sourav [6 ]
Roy, Susanta Sinha [6 ]
Mohamed, Julie Juliewatty [7 ]
Avasthi, Devesh Kumar [1 ]
Mathur, Ashish [1 ]
机构
[1] UPES, Ctr Interdisciplinary Res & Innovat CIDRI, Dehra Dun, India
[2] UPES, Sch Adv Engn, Dept Chem, Dehra Dun, India
[3] Suranaree Univ Technol, Sch Ceram Engn, Nakhon Ratchasima, Thailand
[4] UPES, Sch Hlth Sci & Technol, Dehra Dun, India
[5] Suranaree Univ Technol, Inst Med, Nakhon Ratchasima, Thailand
[6] Shiv Nadar Univ Inst Eminence, Sch Nat Sci, Dept Phys, Greater Noida, India
[7] Univ Malaysia Kelantan, Fac Bioengn & Technol, Dept Mat Technol, Kota Baharu, Malaysia
关键词
SARS-CoV-2; Nucleic Acid; COVID-19; Electrochemical Biosensor; Ti 3 C 2 T x -MXene; Screen Printed Carbon Electrode;
D O I
10.1016/j.microc.2023.109521
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The SARS-CoV-2 virus poses a major risk to human health which has put a tremendous strain on already stretched healthcare resources. Despite continuous improvements in Coronavirus Disease-19 (COVID-19) detection, treatment technology and ongoing global immunization efforts, the lethal virus has undergone several mutations and is still claiming millions of lives worldwide. In this respect, the development of a hybridization based nucleic acid biosensor for SARS-CoV-2 virus is the major focus of the current effort in response to the critical demand for developing quick and accurate diagnostic methods. Herein, we employ Screen Printed Carbon Electrode (SPCE) coated with Ti3C2Tx-MXene nanosheets followed by amino-functionalized probe DNA (NH2- pDNA) as a robust surface for the sensing of SARS-CoV-2. Electrochemical impedance spectroscopy, cyclic voltammetry and differential pulse voltammetry were employed for assessing the electrochemical behavior of NH2- pDNA/Ti3C2Tx/SPCE bioelectrode. Meanwhile, the analytical sensor response for SARS-CoV-2 was studied using impedance within target DNA concentration of 0.1 pM 1 mu M. The developed biosensor displayed detection limit of 0.004 pM, showing a high degree of selectivity in the presence of non-complementary interferents with a shelf life of 40 days. Additionally, a good linearity for the detection of target sequence in spiked serum samples was established; as a result, exhibiting huge potential for use in the contemporary healthcare sector for fast, accurate and reliable diagnosis of COVID-19 in a point-of-care scenario.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Nucleic Acid-Based Diagnostic Tests for the Detection SARS-CoV-2: An Update
    Yu, Choo Yee
    Chan, Kok Gan
    Yean, Chan Yean
    Ang, Geik Yong
    DIAGNOSTICS, 2021, 11 (01)
  • [2] Rapid, multiplexed, and nucleic acid amplification-free detection of SARS-CoV-2 RNA using an electrochemical biosensor
    Kashefi-Kheyrabadi, Leila
    Nguyen, Huynh Vu
    Go, Anna
    Baek, Changyoon
    Jang, Nayoon
    Lee, Jiwon Michelle
    Cho, Nam-Hyuk
    Min, Junhong
    Lee, Min-Ho
    BIOSENSORS & BIOELECTRONICS, 2022, 195
  • [3] An Effective SARS-CoV-2 Electrochemical Biosensor with Modifiable Dual Probes Using a Modified Screen-Printed Carbon Electrode
    Pang, Sow-Neng
    Lin, Yu-Lun
    Yu, Kai-Jie
    Chiou, Yueh-Er
    Leung, Wai-Hung
    Weng, Wen-Hui
    MICROMACHINES, 2021, 12 (10)
  • [4] Recent advances of functional nucleic acid-based sensors for point-of-care detection of SARS-CoV-2
    Wenxian Zhang
    Ying He
    Zhe Feng
    Jingjing Zhang
    Microchimica Acta, 2022, 189
  • [5] Recent advances of functional nucleic acid-based sensors for point-of-care detection of SARS-CoV-2
    Zhang, Wenxian
    He, Ying
    Feng, Zhe
    Zhang, Jingjing
    MICROCHIMICA ACTA, 2022, 189 (03)
  • [6] Electrochemical Biosensor for SARS-CoV-2 cDNA Detection Using AuPs-Modified 3D-Printed Graphene Electrodes
    Silva, Luiz R. G.
    Stefano, Jessica S.
    Orzari, Luiz O.
    Brazaca, Lais C.
    Carrilho, Emanuel
    Marcolino-Junior, Luiz H.
    Bergamini, Marcio F.
    Munoz, Rodrigo A. A.
    Janegitz, Bruno C.
    BIOSENSORS-BASEL, 2022, 12 (08):
  • [7] Antisense oligonucleotide conjugated gold nanoconstructs-based electrochemical biosensor for detection of SARS-CoV-2
    Patil, Tejaswini P.
    Parkhe, Vishakha S.
    Kundale, Somnath S.
    Kamat, Rajanish K.
    Dongale, Tukaram D.
    Patil, Rajendra
    Tiwari, Arpita P.
    APPLIED SURFACE SCIENCE ADVANCES, 2024, 22
  • [8] Analysis of Nucleic Acid and Antibody Detection Results for SARS-CoV-2 Infection
    Chen, Juanjuan
    Niu, Zhili
    Li, Huan
    Tang, Dongling
    Zhang, Pingan
    ARCHIVES OF IRANIAN MEDICINE, 2021, 24 (05) : 427 - 433
  • [9] Colorimetric and electrochemical detection of SARS-CoV-2 spike antigen with a gold nanoparticle-based biosensor
    Karakus, Erman
    Erdemir, Eda
    Demirbilek, Nisa
    Liv, Lokman
    ANALYTICA CHIMICA ACTA, 2021, 1182
  • [10] "Two-step" signal amplification for ultrasensitive detection of dopamine in human serum sample using Ti3C2Tx-MXene
    Chavan, Sachin Ganpat
    Rathod, Pooja Ramrao
    Koyappayil, Aneesh
    Go, Anna
    Lee, Min-Ho
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 404