Simplifying biometry in oil-filled eyes: A novel formula for axial length calculation in eyes with 1000 cSt silicone oil

被引:1
作者
Kapoor, Monika [1 ,3 ]
Venkatesh, Pradeep [2 ]
Chawla, Rohan [2 ]
Temkar, Shreyas [2 ]
Aggarwal, Esha [2 ]
机构
[1] Nethradhama Super Special Eye Hosp, Bengaluru, Karnataka, India
[2] AIIMS, Rajendra Prasad Ctr Ophthalm Sci, New Delhi, India
[3] 658-1 5th Block, 11th A Main Rd, Bengaluru 560041, Karnataka, India
关键词
Axial length in oil-filled eye; axial length in silicone oil; biometry in oil-filled eyes; biometry in silicone oil; cataract in oil-filled eyes; postvitrectomy cataract; INTRAOPERATIVE BIOMETRY; LENS IMPLANTATION; CATARACT; REMOVAL; PHACOEMULSIFICATION; RELIABILITY; VITRECTOMY;
D O I
10.4103/ijo.IJO_2187_22
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To derive a formula for accurate axial length (AL) assessment using routine ultrasound in silicone oil-filled eyes, where optical biometry is unavailable or not possible. Methods: This was a prospective, consecutive, nonrandomized study of 50 eyes of 50 patients conducted in a tertiary care hospital in North India. AL measurements were taken using both manual A-scan and IOL master, both in silicone oil-filled status and 3 weeks after silicone oil removal. A correction factor of 0.7 was used for AL adjustment in oil-filled eyes. The corrected AL (cAL) was compared with IOL master values in oil-filled eyes. Agreement analysis was carried out using Bland Altman plot. Linear regression analysis was done using uncorrected manual AL to find a new equation. Data was analyzed using Stata 14. A P value <0.05 was taken as significant. Results: The study included 40 males and 10 females, with an age range of 6-83 years (mean 41.9 years). The mean AL of the oil-filled eye as measured by manual A-scan was 31.76 mm +/- 3.09 and by IOL master was 24.7 mm +/- 1.74. Linear regression analysis was performed in randomly selected 35 eyes of the observed data to obtain a new equation: predicted AL (PAL) = 14 + 0.3 x manual AL. The mean difference between PAL and optically measured AL with silicone oil in situ was 0.98 +/- 1.67. Conclusion: We propose a new formula for better prediction of the correct AL in silicone oil-filled eyes using ultrasound-based AL measurement.
引用
收藏
页码:2466 / 2468
页数:3
相关论文
共 19 条
[1]   Phacoemulsification with transpupillary silicone oil removal and lens implantation through a corneal incision using topical anesthesia [J].
Boscia, F ;
Recchimurzo, N ;
Cardascia, N ;
Sborgia, L ;
Ferrari, TM ;
Sborgia, C .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (06) :1113-1119
[2]   Duration of vitrectomy and postoperative cataract in the vitrectomy for macular hole study [J].
Cheng, LY ;
Azen, SP ;
El-Bradey, MH ;
Scholz, BM ;
Chaidhawangul, S ;
Toyoguchi, M ;
Freeman, WR .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2001, 132 (06) :881-887
[3]   Phacoemulsification combined with silicone oil removal through a posterior capsulorhexis [J].
Dada, VK ;
Talwar, D ;
Sharma, N ;
Dada, T ;
Sudan, R ;
Azad, RV .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (08) :1243-1247
[4]   COMPARISON OF REFRACTIVE OUTCOME USING INTRAOPERATIVE BIOMETRY AND PARTIAL COHERENCE INTERFEROMETRY IN SILICONE OIL-FILLED EYES [J].
El-Baha, Samir Mohamed ;
Hemeida, Tarek Samir .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2009, 29 (01) :64-68
[5]   Intraoperative biometry for intraocular lens (IOL) power calculation at silicone oil removal [J].
El-Baha, SM ;
El-Samadoni, A ;
Idris, HF ;
Rashad, KM .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2003, 13 (07) :622-626
[6]  
Findl O, 2002, DEV OPHTHALMOL, V34, P131
[7]   The acoustic lighthouse effect - An ultrasonic response met in eyes after vitreoretinal surgery with silicone oil [J].
Fledelius, HC ;
Scherfig, E .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2000, 78 (01) :89-92
[8]   The problems of biometry in combined silicone oil removal and cataract extraction - A clinical trial [J].
Ghoraba, HH ;
El-Dorghamy, AA ;
Atia, AF ;
Yassin, ABDEAI .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2002, 22 (05) :589-596
[9]   Refractive outcome of silicone oil removal and intraocular lens implantation using her interferometry [J].
Habibabadi, HF ;
Hashemi, H ;
Jalali, KH ;
Amini, A ;
Esfahani, MR .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2005, 25 (02) :162-166
[10]  
Haigis W, 2002, DEV OPHTHALMOL, V34, P119