Lacrimal and meibomian gland evaluation in dry eye disease: A mini-review

被引:10
作者
Singh, Swati [1 ,4 ,7 ]
Donthineni, Pragnya Rao [2 ]
Srivastav, Saumya [3 ]
Jacobi, Christina [5 ,6 ]
Basu, Sayan [2 ]
Paulsen, Friedrich [4 ]
机构
[1] LV Prasad Eye Inst, Ophthalm Plast Surg Serv, KAR Campus, Hyderabad, Telangana, India
[2] LV Prasad Eye Inst, Cornea Inst, KAR Campus, Hyderabad, Telangana, India
[3] LV Prasad Eye Inst, Brien Holden Eye Res Ctr, Hyderabad, Telangana, Pakistan
[4] Friedrich Alexander Univ Erlangen Nuremberg, Inst Funct & Clin Anat, Erlangen, Germany
[5] AUGEN & HAUT Zentrum Praxis Dr Jacobi, Erlangen, Germany
[6] Friedrich Alexander Univ Erlangen Nuremberg, Erlangen, Germany
[7] LV Prasad Eye Inst, Ophthalm Plast Surg Serv, Hyderabad, Telangana, India
关键词
Dry eye disease; lacrimal gland; lipid layer thickness; meibomian glands; tear break-up time; tear meniscus height; OPTICAL COHERENCE TOMOGRAPHY; LIPID LAYER THICKNESS; TEAR MENISCUS HEIGHT; SCHIRMER TEST; FILM; REPEATABILITY; DYSFUNCTION; DIAGNOSIS; MEIBOGRAPHY; DEFICIENCY;
D O I
10.4103/IJO.IJO_2622_22
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Lacrimal and meibomian glands contribute to the aqueous and lipid components of tear film, respectively. Their evaluation remains central to diagnosing and managing dry eye disease (DED). The review discusses the differences and reliability of various diagnostic tests and commercially available devices used for DED diagnosis. Slit-lamp-based techniques are direct palpebral lobe and tear flow assessment, Schirmer test, meibum quality and expressibility, and evaluation of tear meniscus height. Non-invasive tear meniscus height (TMH), tear break-up time (TBUT), lipid layer thickness (LLT), and meibography are machine-based diagnostic tests. The structure-function correlation of the tear-producing glands gives more comprehensive details than either information alone. Many devices are available in the market, which make DED diagnosis an easy feat, but the tests should be interpreted keeping in mind the intra-observer and inter-observer repeatability. Also, the tear film displays a huge variability as per the environmental conditions and impact of blinking. Hence, the examiner should be well versed with the techniques and repeat the test two to three times to obtain an average reading, which is more reliable. The recommended sequence of tests for diagnosing DED is a dry eye questionnaire, TMH, LLT, NIBUT (FBUT if non-invasive test is unavailable but should be performed after osmolarity), tear osmolarity, meibography, and ocular surface staining. Invasive tests such as Schirmer should be performed after the non-invasive tear film diagnostic testing.
引用
收藏
页码:1090 / 1098
页数:9
相关论文
共 61 条
  • [1] Meibomian Gland Morphology Is a Sensitive Early Indicator of Meibomian Gland Dysfunction
    Adil, Mohammed Yasin
    Xiao, Jiaxin
    Olafsson, Jonatan
    Chen, Xiangjun
    Lagali, Neil S.
    Raeder, Sten
    Utheim, Oygunn A.
    Dartt, Darlene A.
    Utheim, Tor P.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 200 : 16 - 25
  • [2] Diagnosis of Dry Eye by Tear Meniscus Measurements Using Anterior Segment Swept Source Optical Coherence Tomography
    Akiyama, Reina
    Usui, Tomohiko
    Yamagami, Satoru
    [J]. CORNEA, 2015, 34 : S115 - S120
  • [3] Proposed Diagnostic Criteria for Obstructive Meibomian Gland Dysfunction
    Arita, Reiko
    Itoh, Kouzo
    Maeda, Syuji
    Maeda, Koshi
    Furuta, Ayumu
    Fukuoka, Shima
    Tomidokoro, Atsuo
    Amano, Shiro
    [J]. OPHTHALMOLOGY, 2009, 116 (11) : 2058 - 2063
  • [4] Morphological Evaluation of Meibomian Glands Using Noncontact Infrared Meibography
    Ban, Yumiko
    Shimazaki-Den, Seika
    Tsubota, Kazuo
    Shimazaki, Jun
    [J]. OCULAR SURFACE, 2013, 11 (01) : 47 - 53
  • [5] Clinical evaluation of the Oculus Keratograph
    Best, N.
    Drury, L.
    Wolffsohn, J. S.
    [J]. CONTACT LENS & ANTERIOR EYE, 2012, 35 (04) : 171 - 174
  • [7] Interexaminer Reproducibility of Optical Coherence Tomography for Measuring the Tear Film Meniscus
    Canan, Handan
    Altan-Yaycioglu, Rana
    Ulas, Burak
    Sizmaz, Selcuk
    Coban-Karatas, Muge
    [J]. CURRENT EYE RESEARCH, 2014, 39 (12) : 1145 - 1150
  • [8] Repeatability of tear meniscus evaluation using spectral-domain Cirrus® HD-OCT and time-domain Visante® OCT
    Chan, Hiok Hong
    Zhao, Yang
    Tun, Tin A.
    Tong, Louis
    [J]. CONTACT LENS & ANTERIOR EYE, 2015, 38 (05) : 368 - 372
  • [9] Advances in dry eye imaging: the present and beyond
    Chan, Tommy C. Y.
    Wan, Kelvin H.
    Shih, Kendrick C.
    Jhanji, Vishal
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2018, 102 (03) : 295 - 301
  • [10] Agreement between Automated and Traditional Measures of Tear Film Breakup
    Cox, Stephanie M.
    Nichols, Kelly K.
    Nichols, Jason J.
    [J]. OPTOMETRY AND VISION SCIENCE, 2015, 92 (09) : E257 - E263