Basal osteotomy of the first metacarpal using patient-specific guides and instrumentation: biomechanical and 3D CT-based analysis

被引:2
|
作者
Nuesch, Clea [1 ]
Schweizer, Andreas [1 ]
Weber, Andreas [1 ]
Reissner, Lisa [1 ]
机构
[1] Balgrist Univ, Hosp Zurich, Div Hand Surg, Forch str 340, CH-8008 Zurich, Switzerland
关键词
Trapeziometacarpal osteoarthritis; Extension osteotomy; Three-dimensional patient-specific planning and instrumentation; Peak load zone; Joint; Articular surface; THUMB CARPOMETACARPAL JOINT; TRAPEZIOMETACARPAL OSTEOARTHRITIS; ARTICULAR-CARTILAGE; EXTENSION OSTEOTOMY; RECONSTRUCTION; ARTHRITIS; OUTCOMES;
D O I
10.1007/s00402-023-05122-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionThe aim of this study was to investigate the radiological outcomes of proximal closing metacarpal extension osteotomies using patient-specific guides and instruments (PSI) in early-stage trapeziometacarpal osteoarthritis to gain further insight into the joint loading surface and the benefits of the procedure.MethodsIn a prospective observational study, nine patients were included between 11/2020 and 12/2021, undergoing a total of ten proximal metacarpal extension osteotomies for basal thumb osteoarthritis. Computer-assisted surgical planning was performed using computed tomography (CT) and three-dimensional (3D) segmentation, allowing the fabrication of 3D-printed PSIs for surgical treatment. Inclusion criteria were a 1-year follow-up by CT to assess postoperative correction of the positional shift of the first metacarpal (MC1) and the location of peak loads compared with the preoperative situation.ResultsRadiographic analysis of the peak loading zone revealed a mean displacement on the articular surface of the trapezius of 0.4 mm +/- 1.4 mm to radial and 0.1 mm +/- 1.2 mm to palmar, and on the articular surface of the MC1 of 0.4 mm +/- 1.4 mm to radial and 0.1 mm +/- 1.2 mm to dorsal.ConclusionThere were trends indicating that a flatter pressure distribution and a dorsal shift of the peak loading zone may contribute to an improvement in subjective pain and patient satisfaction associated with this surgical procedure. The non-significant radiological results and the minor dorsal-radial shifts in our small study group limit a firm conclusion.Level of evidenceIII.
引用
收藏
页码:551 / 558
页数:8
相关论文
共 30 条
  • [21] Design of a Metal 3D Printing Patient-Specific Repairing Thin Implant for Zygomaticomaxillary Complex Bone Fracture Based on Buttress Theory Using Finite Element Analysis
    Wang, Yu-Tzu
    Chen, Chih-Hao
    Wang, Po-Fang
    Chen, Chien-Tzung
    Lin, Chun-Li
    APPLIED SCIENCES-BASEL, 2020, 10 (14):
  • [22] Augmented patient-specific facial prosthesis production using medical imaging modelling and 3D printing technologies for improved patient outcomes
    Mohammed, Mazher I.
    Cadd, Brenton
    Peart, Greg
    Gibson, Ian
    VIRTUAL AND PHYSICAL PROTOTYPING, 2018, 13 (03) : 164 - 176
  • [23] Rehearsals using patient-specific 3D-printed aneurysm models for simulation of endovascular embolization of complex intracranial aneurysms: 3D SIM study
    Le Bras, Anthony
    Boustia, Fakhreddine
    Janot, Kevin
    Le Pabic, Estelle
    Ouvrard, Mathilde
    Fougerou-Leurent, Claire
    Ferre, Jean-Christophe
    Gauvrit, Jean-Yves
    Eugene, Francois
    JOURNAL OF NEURORADIOLOGY, 2023, 50 (01) : 86 - 92
  • [24] A novel 3D-printed patient-specific instrument based on "H-point" for medial opening wedge high tibial osteotomy: a cadaver study
    Liu, Guo-Bin
    Liu, Sen
    Zhu, Chao-Hua
    Li, Jia
    Li, Jun
    Jia, Guo-Xing
    Dong, Wei
    Zhao, Feng
    Huang, Ye
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [25] A 2D/3D correspondence building method for reconstruction of a patient-specific 3D bone surface model using point distribution models and calibrated X-ray images
    Zheng, Guoyan
    Gollmer, Sebastian
    Schumann, Steffen
    Dong, Xiao
    Feilkas, Thomas
    Gonzalez Ballester, Miguel A.
    MEDICAL IMAGE ANALYSIS, 2009, 13 (06) : 883 - 899
  • [26] Limb-Sparing Surgery and Stifle Arthrodesis Using Patient-Specific 3D-Printed Guides and Endoprosthesis for Distal Femoral Chondrosarcoma in a Dog: A Case Report
    Panichi, Enrico
    Tabbi, Marco
    Principato, Gaetano
    Dal Magro, Valentina
    Valentini, Fabio
    Currenti, Marco
    Macri, Francesco
    ANIMALS, 2025, 15 (05):
  • [27] HIGHLY ACCURATE AUTOMATED PATIENT-SPECIFIC 3D BONE POSE AND SCALE ESTIMATION USING BI-PLANAR POSE-INVARIANT PATCHES IN A CNN-BASED 3D/2D REGISTRATION FRAMEWORK
    Khameneh, Nahid Babazadeh
    Vazquez, Carlos
    Cresson, Thierry
    Lavoie, Frederic
    de Guise, Jacques
    2021 IEEE 18TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2021, : 681 - 684
  • [28] Improved Accuracy of Coronal Alignment Can Be Attained Using 3D-Printed Patient-Specific Instrumentation for Knee Osteotomies: A Systematic Review of Level III and IV Studies
    Aman, Zachary S.
    DePhillipo, Nicholas N.
    Peebles, Liam A.
    Familiari, Filippo
    LaPrade, Robert F.
    Dekker, Travis J.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2022, 38 (09) : 2741 - 2758
  • [29] Patient-specific registration of 3D CT angiography (CTA) with X-ray fluoroscopy for image fusion during transcatheter aortic valve implantation (TAVI) increases performance of the procedure
    Vernikouskaya, I.
    Rottbauer, W.
    Seeger, J.
    Gonska, B.
    Rasche, V.
    Woehrle, Jochen
    CLINICAL RESEARCH IN CARDIOLOGY, 2018, 107 (06) : 507 - 516
  • [30] Does Viewing the ACL Femoral Footprint End on Using a High Medial Portal Produce Better Tunnel Placement as Compared to Viewing it from a Lateral Portal while Drilling: A 3D CT-based Pilot Study
    Mhaskar, Vikram A.
    Singh, Ajay K.
    Soni, Pankaj
    Maheshwari, Jitendra
    INDIAN JOURNAL OF ORTHOPAEDICS, 2021, 55 (02) : 368 - 374