Effect of an Ultrahigh b Value of 3000 s/mm2 and the Minimal Echo-time on Image Quality and the T2 Shine-through Effect in Diffusion-weighted Imaging of the Liver at 3T: Phantom and Clinical Pilot Studies

被引:1
|
作者
Fukushima, Keita [1 ]
Sano, Katsuhiro [2 ,3 ]
Machida, Haruhiko [2 ,4 ,6 ]
Kariyasu, Toshiya [2 ,4 ]
Yoshioka, Tatsuya [1 ]
Takahashi, Sanae [1 ]
Nakanishi, Akihito [1 ]
Kusahara, Hiroshi [5 ]
Yokoyama, Kenichi [2 ]
机构
[1] Kyorin Univ Hosp, Dept Radiol, Mitaka, Tokyo, Japan
[2] Kyorin Univ, Fac Med, Dept Radiol, Mitaka, Tokyo, Japan
[3] Juntendo Univ, Dept Radiol, Tokyo, Japan
[4] Tokyo Womens Med Univ, Dept Radiol, Adachi Med Ctr, Tokyo, Japan
[5] Canon Med Syst Corp, MRI Syst Div, Otawara, Tochigi, Japan
[6] Kyorin Univ, Fac Med, Dept Radiol, 6-20-2 Shinkawa, Otawara, Tokyo 1818611, Japan
关键词
diffusion-weighted imaging; hepatic hemangioma; high-gradient magnetic field; T2 shine-through effect; ultrahigh b value; MRI; UTILITY; BENIGN;
D O I
10.2463/mrms.mp.2021-0077
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the effect of an ultrahigh b value of 3000 s/mm2 and the minimal TE of 53 ms on image quality and T2 shine-through effect in liver diffusion-weighted imaging (DWI) using a 3-Tesla MRI scanner with a peak gradient of 100 mT/m.Methods: At b values of 1000 and 3000 s/mm2 and at the minimal (44-53 ms) and routine TEs (70 ms), DWI of our original phantom and liver DWI in 10 healthy volunteers and 26 patients with 35 hepatic hemangiomas were acquired with this scanner, and the quantified SNR of the phantom and the hepatic parenchyma in the volunteers and the contrast-to-noise ratio (CNR) of the hepatic hemangiomas were calculated; two independent readers qualitatively graded the overall image quality in the volunteers and determined the presence or absence of the T2 shine-through effect related to the hemangiomas in the patients. We compared the SNR and subjective overall image quality between the minimal and routine TEs and the CNR and incidence of the T2 shine-through effect between b values of 1000 and 3000 s/mm2. Interreader agreement was also evaluated. Results: The SNR at both b values was significantly higher, and the subjective overall image quality at a b value of 3000 s/mm2 was significantly better at the minimal TE than at the routine TE (P < 0.05 for all). The CNR at both TEs and the incidence of the T2 shine-through effect at the minimal TE were significantly lower at a b value of 3000 s/mm2 than at a b value of 1000 s/mm2 (P < 0.05 for all). Inter-reader agreement was excellent.Conclusion: Liver DWI at the ultrahigh b value can reduce the T2 shine-through effect with improvement of image quality using the minimal TE.
引用
收藏
页码:232 / 240
页数:9
相关论文
共 6 条
  • [1] The value of b required to avoid T2 shine-through from old lacunar infarcts in diffusion-weighted imaging
    Geijer, B
    Sundgren, PC
    Lindgren, A
    Brockstedt, S
    Ståhlberg, F
    Holtås, S
    NEURORADIOLOGY, 2001, 43 (07) : 511 - 517
  • [2] The value of b required to avoid T2 shine-through from old lacunar infarcts in diffusion-weighted imaging
    B. Geijer
    P. C. Sundgren
    A. Lindgren
    S. Brockstedt
    F. Ståhlberg
    S. Holtås
    Neuroradiology, 2001, 43 : 511 - 517
  • [3] Pitfalls of Diffusion-Weighted Imaging: Clinical Utility of T2 Shine-through and T2 Black-out for Musculoskeletal Diseases
    Kim, Yuri
    Lee, Seul Ki
    Kim, Jee-Young
    Kim, Jun-Ho
    DIAGNOSTICS, 2023, 13 (09)
  • [4] Hepatic hemangiomas: Factors associated with T2 shine-through effect on diffusion-weighted MR sequences
    Duran, Rafael
    Ronot, Maxime
    Kerbaol, Anne
    Van Beers, Bernard
    Vilgrain, Valerie
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (03) : 468 - 478
  • [5] Added Value of High-b-Value (b=3000 s/mm2) Diffusion-Weighted Imaging at 3 T in Relation to Fluid-Attenuated Inversion Recovery Images for the Evaluation of Cortical Lesions in Inflammatory Brain Diseases
    Iwashita, Koya
    Hirai, Toshinori
    Kitajima, Mika
    Shigematsu, Yoshinori
    Uetani, Hiroyuki
    Iryo, Yasuhiko
    Azuma, Minako
    Hayashida, Eri
    Ando, Yukio
    Murakami, Ryuji
    Yamashita, Yasuyuki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (03) : 338 - 342
  • [6] High-b-Value Diffusion-Weighted Imaging at 3 T to Detect Prostate Cancer: Comparisons Between b Values of 1,000 and 2,000 s/mm2
    Kim, Chan Kyo
    Park, Byung Kwan
    Kim, Bohyun
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (01) : W33 - W37