An efficient strategy triggered crosslinking of polyethylene and its application in degassing-free ultrahigh voltage power cables

被引:4
作者
Sun, Wu-Ji [1 ,2 ,3 ]
Liu, Xiong-Jun [1 ]
Yuan, Li-Juan [1 ]
Xiao, Han [1 ]
Lu, Jian-Mei [2 ,3 ]
机构
[1] Jiangsu Shangshang Cable Grp, Res Inst Rubber & Plast Mat Sci & Technol, Changzhou, Peoples R China
[2] Soochow Univ, Coll Chem Chem Engn & Mat Sci, Collaborat Innovat Ctr Suzhou Nano Sci & Technol, Natl United Engn Lab Functionalized Environm Adsor, Suzhou, Peoples R China
[3] Soochow Univ, Coll Chem Chem Engn & Mat Sci, Collaborat Innovat Ctr Suzhou Nano Sci & Technol, Natl United Engn Lab Functionalized Environm Adsor, Suzhou 215123, Peoples R China
基金
中国国家自然科学基金;
关键词
crosslinked polyethylene; degassing-free; finite element analysis; ultrahigh voltage; LOW-DENSITY POLYETHYLENE; MOLECULAR-WEIGHT POLYETHYLENE; LINKED LOW-DENSITY; PHYSICAL-PROPERTIES; THERMAL-PROPERTIES; PEROXIDE; BEHAVIOR; MELT;
D O I
10.1002/app.53844
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Polyethylene has excellent electrical insulation, but its low thermal stability and breakdown strength limit its application in the field of high-voltage (HV) and ultrahigh voltage (UHV) power cables. In this work, we have developed a new organic peroxide, 2,5-dimethyl-2,5-di(tert-butylperoxy) hexane (Bi25), which can efficiently trigger the crosslinking of polyethylene (Bi25-XLPE). Bi25-XLPE does not produce gas byproducts and has a longer scorching time. All performance of Bi25-XLPE sheets fulfill the standard of the 500 kV power cable insulation due to the void-free nature, higher crosslinking density and crystallinity. In addition, one 500 kV power cable model was constructed by COMSOL, which confirmed the breakdown strength (up to 61.66 kV/mm) and stability of Bi25-XLPE.
引用
收藏
页数:9
相关论文
共 29 条
[21]   Research and development of ±250 kV DC XLPE cables [J].
Terashima, K ;
Suzuki, H ;
Hara, M ;
Watanabe, K .
IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (01) :7-16
[22]   Recent Advances in Cross-linked Polyethylene-based Nanocomposites for High Voltage Engineering Applications: A Critical Review [J].
Thomas, Jince ;
Joseph, Blessy ;
Jose, Josmin. P. ;
Maria, Hanna J. ;
Main, Priyanka ;
Rahman, Azerai Ali ;
Francis, Bejoy ;
Ahmad, Zakiah ;
Thomas, Sabu .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2019, 58 (46) :20863-20879
[23]   Study on Storage Activity of Cross-Linkable Polyethylene Material Used for High-Voltage Cables [J].
Wang, Xia ;
Wang, Y. Z. ;
Ye, X. Z. ;
Wu, K. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2022, 29 (02) :437-445
[24]   Crosslinking of low density polyethylene with octavinyl polyhedral oligomeric silsesquioxane as the crosslinker [J].
Wu, Jiachun ;
Wu, Zi Liang ;
Yang, Hongmei ;
Zheng, Qiang .
RSC ADVANCES, 2014, 4 (83) :44030-44038
[25]   Controlling Factors of Degassing in Crosslinked Polyethylene Insulated Cables [J].
Youn, Dong Joon ;
Li, Jingfa ;
Livazovic, Sara ;
Sun, Yabin ;
Sun, Shuyu .
POLYMERS, 2019, 11 (09)
[26]   Theoretical study on the reaction of maleic anhydride in the UV radiation cross-linking process of polyethylene [J].
Zhang, Hui ;
Shang, Yan ;
Zhao, Hong ;
Wang, Xuan ;
Han, Baozhong ;
Li, Zesheng .
POLYMER, 2017, 133 :232-239
[27]  
Zhenguo Y., 2018, EL PACKAG TECH CONF, V5, P1
[28]  
Zhiwei L., 2018, J XIAN JIAOTONG U, V52, P1
[29]   Electrical properties of silane crosslinked polyethylene in comparison with DCP crosslinked polyethylene [J].
Zhu, Y ;
Yoon, HG ;
Suh, KS .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1999, 6 (02) :164-168