Purpose Nonunion is a common complication after a distal femoral fracture (DFF). Standard treatment consists of revision plating and/or bone grafting. Single lateral plating for a distal femoral nonunion can be insufficient in case of a persistent medial gap and compromised bone stock. Alternatively, dual plating can be used to treat a distal femoral nonunion, but to date there is no Gold standard. The aim of our study was to report our results after use of a minimally invasively placed proximal humeral internal locking system (Philos) plate as a medial buttress in the treatment of a distal femoral nonunion. Methods Fifteen adult patients with a distal femoral nonunion were prospectively entered in a trauma database and retrospectively assessed. All patients underwent a similar operation, which included removal of failed hardware, nonunion debridement, fixation with a lateral plate, and a medial Philos plate combined with bone grafting. Data collected included union rate, time to union, complications and functional outcome. Results In twelve out of fifteen patients (80%), the fracture united after our index operation. Median time to union was 4.8 months (range 1.6-15). Three patients (20%) needed additional bone grafting surgery. One patient underwent a Judet quadricepsplasty. Conclusion This study suggests that the Philos plate is a safe and effective adjunct as a medial buttress plate for distal femoral nonunions.
引用
收藏
页码:425 / 433
页数:9
相关论文
共 50 条
  • [31] Open Reduction and Internal Fixation of Proximal Humeral Fractures with Use of the Locking Proximal Humerus Plate Results of a Prospective, Multicenter, Observational Study
    Suedkamp, N.
    Bayer, J.
    Hepp, P.
    Voigt, C.
    Oestern, H.
    Kaeaeb, M.
    Luo, C.
    Plecko, M.
    Wendt, K.
    Koestler, W.
    Konrad, G.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (06) : 1320 - 1328
  • [32] Tibiotalocalcaneal arthrodesis by using proximal humeral locking plate
    Ozer, Devrim
    Bayhan, Avni Ilhan
    Keskin, Abdi
    Sari, Seckin
    Kaygusuz, Mehmet Akif
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2016, 50 (04) : 389 - 392
  • [33] ! Treatment of Proximal Humeral Nonunions With a Locked Plate and an Intramedullary Strut Autograft
    Smith, Geoffrey C. S.
    Cass, Ben
    Young, Allan
    TECHNIQUES IN ORTHOPAEDICS, 2014, 29 (01) : 39 - 42
  • [34] Complications of the locking plate for displaced proximal humeral fractures
    Lu Yi
    Wang Man-yi
    Zhu Yi-ming
    Jiang Chun-yan
    CHINESE MEDICAL JOURNAL, 2010, 123 (19) : 2671 - 2675
  • [35] Technical difficulties and mechanical failure of distal femoral locking compression plate (DFLCP) in management of unstable distal femoral fractures
    Siddiqui, Yasir Salam
    Mohd, Julfiqar
    Abbas, Mazhar
    Gupta, Keshav
    Khan, Mohammad Jesan
    Istiyak, Md
    INTERNATIONAL JOURNAL OF BURNS AND TRAUMA, 2021, 11 (01): : 9 - 19
  • [36] Implementation of locking compression plate together with intramedullary fibular graft in atrophic type humeral nonunions
    Erden, Erturer Ramazan
    Arda, Canar
    Mesut, Sonmez Mehmet
    Adnan, Kara
    Bulent, Ozcelik Ismail
    Irfan, Ozturk
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2012, 22 (08) : 661 - 665
  • [37] Adult Proximal Humerus Locking Plate for the Treatment of a Pediatric Subtrochanteric Femoral Nonunion: A Case Report
    Cortes, Luis E.
    Triana, Miguel
    Vallejo, Francisco
    Slongo, Theddy F.
    Streubel, Philipp N.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (07) : E63 - E67
  • [38] Early results in the treatment of proximal humeral fractures with a polyaxial locking plate
    Erhardt, Johannes B.
    Roderer, G.
    Grob, K.
    Forster, T. N.
    Stoffel, K.
    Kuster, M. S.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2009, 129 (10) : 1367 - 1374
  • [39] The treatment of complex proximal humeral fractures: analysis of the results of 55 cases treated with PHILOS plate
    Fattoretto D.
    Borgo A.
    Iacobellis C.
    MUSCULOSKELETAL SURGERY, 2016, 100 (2) : 109 - 114
  • [40] Comparison of the clinical outcomes and radiological parameters between the greater tuberosity strengthened proximal humeral plate and the proximal humeral internal locking system plate in the minimally invasive plate osteosynthesis treatment of proximal humeral fractures involving the greater tuberosity: a retrospective cohort study
    Le, Jiadi
    Lu, Jianpeng
    Zhang, Jianxiong
    Wu, Zhenghao
    Chen, Long
    BMC MUSCULOSKELETAL DISORDERS, 2025, 26 (01)